If you specified BOTH or GRAPHIC for report mode on ERB3RD3, RMF™ displays the first Graphic Parameter Definition panel, ERB3RDB.
On this panel, you can specify general information about the graphic version of the report.
Figure 1 is an example of the Graphic Parameter Definition panel ERB3RDB that specifies general information for the graphic version of the SYSINFO report:
ERB3RDB RMF Report Format Definition
Command ===>
Report Name: SYSCPU Section 7: Graphic Parameter Definition
WLM Mode: GOAL
Definitions on this panel are independent of WLM mode.
Enter the following information. To continue press ENTER.
To quit enter CANCEL. To go backwards press END.
GENERAL INFORMATION
NAME FOR HELP PANEL ===> ERBGSYS0 Name of HELP PANEL, if any
TITLE FOR Y-AXIS ===> Average Number of Active Users
MINIMUM AXIS RANGE ===> 1 Axis will contain at least this
number of data points
SELECTION RULE ===> 1 Specify 0, 1, 2 or 3
For an example of the graphic parameter table (ERBPTGS3), see Monitor III data reporter tables.
If the length of the largest bar in the report exceeds the value you specify, RMF uses the length of the largest bar.
For an example of the graphic parameter table (ERBPTGS3), see Monitor III data reporter tables.
For an example of the graphic parameter table (ERBPTGS3), see Monitor III data reporter tables. For a description of logical line number and sequence number, see the panel field description for ERB3RD3 ( Figure 1).
Press ENTER to display the next panel, ERB3RDC, the second Graphic Parameter Definition panel.
On this panel, you can specify labels for the graphic bars in the report. You can specify variable names for bar type 1 labels and bar type 2 labels.
Figure 2 is an example of the Graphic Parameter Definition panel ERB3RDC.
ERB3RDC RMF Report Format Definition
Command ===>
Report Name: SYSCPU Section 7: Graphic Parameter Definition
WLM Mode: GOAL
Definitions on this panel are independent of WLM mode.
Enter the following information. To continue press ENTER.
To quit enter CANCEL. To go backwards press END.
LABEL INFORMATION FOR BAR TYPE I
PRIMARY LABEL ===> SYSNAMVC Variable name containing label
SECONDARY LABEL ===> ________ Variable name containing label
PRIMARY COMPOSITE ===> _____ Prefix of label
SECONDARY COMPOSITE ===> _____ Prefix of label
LABEL INFORMATION FOR BAR TYPE II
PRIMARY LABEL ===> ________ Variable name containing label
SECONDARY LABEL ===> ________ Variable name containing label
PRIMARY COMPOSITE ===> _____ Prefix of label
SECONDARY COMPOSITE ===> _____ Prefix of label
For example, in Figure 2, the Primary label will appear as average number of active users (SYSNAMVC) on the graphic version of the SYSCPU report.
See Monitor III data reporter tables for examples of the Graphic Parameter table (ERBPTGS3) and the RMF Report Data tables.
See Monitor III data reporter tables for examples of the Graphic Parameter table (ERBPTGS3) and the RMF Report Data tables.
BAR TYPE refers to the number of bars used in the report depending on the logical line and sequence numbers.
See LOGICAL LINE/SEQUENCE NUMBER in the field descriptions for ERB3RD3 ( Figure 1).
Press ENTER to display the next panel, ERB3RDD, the third Graphic Parameter Definition panel.
On this panel, you can specify data columns that you want to appear in the graphic version of the report.
Figure 3 is an example of the Graphic Parameter Definition panel ERB3RDD.
ERB3RDD RMF Report Format Definition
Command ===>
Report Name: SYSCPU Section 7: Graphic Parameter Definition
WLM Mode: GOAL
Definitions on this panel are independent of WLM mode.
Enter the following information. To continue press ENTER.
To quit enter CANCEL. To go backwards press END.
COLUMN SPECIFICATION FOR GRAPHIC BAR TYPES
NAME LEGEND ID TRANS ID BAR TYPE ID
1. ===> SYSADPVC ===> 14 ===> 0 ===> 1
2. ===> SYSADDVC ===> 08 ===> 0 ===> 1
3. ===> SYSADSVC ===> 15 ===> 0 ===> 1
4. ===> SYSADUVC ===> 28 ===> 0 ===> 1
5. ===> SYSADOVC ===> 29 ===> 0 ===> 1
6. ===> SYSADEVC ===> 09 ===> 0 ===> 1
7. ===> SYSAUPVC ===> 19 ===> 0 ===> 1
8. ===> SYSAUDVC ===> 18 ===> 0 ===> 1
9. ===> ________ ===> __ ===> _ ===> _
10. ===> ________ ===> __ ===> _ ===> _
See Monitor III data reporter tables for examples of RMF report data tables.
If you specified label information for only bar type 1 on the report parameter definition panel (ERB3RDC), you must specify bar type 1.