STOP

Read syntax diagramSkip visual syntax diagram
   .-NOSTOP-------------.   
>>-+--------------------+--------------------------------------><
   |            .-M-.   |   
   '-STOP(value-+---+-)-'   
                '-H-'       

Specifies the desired duration for the data gatherer interval in minutes (M) or hours (H). You can specify a value from one minute (1M) to one week (168H or 10080M). RMF™ uses 168H for values above the range. If you do not specify M or H, RMF uses minutes (M).

NOSTOP means that only the session or system command STOP can end the session.

Note: The STOP option applies only to the data gatherer. The operator can use the session command STOP to end the session at any time, regardless of the value specified for this option. The RMF control session remains active until the operator issues a system command STOP.