Description: In z/OS V1R13 and earlier there were no entries in the program properties table for AXRINIT and AXRRXTSS to indicate that these programs needed to run privileged, so you had to manually add PPT entries for AXRINIT and AXRRXTSS into SCHEDxx parmlib members. In z/OS V2R1, these entries are now included in the IBM supplied default program properties table, and you can remove the SCHEDxx PPT specifications for AXRINIT and AXRRXTSS.
Element or feature: | BCP |
When change was introduced: | z/OS V2R1 |
Applies to migration from: | z/OS V1R13 and z/OS V1R12. |
Timing: | Before the first IPL of z/OS V2R1. |
Is the migration action required? | No, but recommended to avoid an unintended override of the IBM shipped default PPT. |
Target system hardware requirements: | None. |
Target system software requirements: | None. |
Other system (coexistence or fallback) requirements: | None. |
Restrictions: | None. |
System impacts: | None. |
Related IBM Health Checker for z/OS check: | None. |
Reference information: z/OS MVS Initialization and Tuning Reference.