IBM Health Checker for z/OS User's Guide
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


SLIP_PER

IBM Health Checker for z/OS User's Guide
SC23-6843-02

Start of change
Description:
Checks to see whether a SLIP PER trap has been continuously active for longer than the threshold.
Reason for check:
An active, but not needed, SLIP PER trap can cause degraded system performance
z/OS® releases the check applies to:
z/OS V2R1 and higher.
Parameters accepted:
Yes, the following parameters are accepted:
TIME(DAYS,n) or TIME(HOURS,n)
TIME(DAYS,n) or TIME(HOURS,n)
Each of which identifies the length of time that a SLIP PER trap must be active before the exception is raised. “n” may range from 1-9999.
User override of IBM® values:
The following shows keywords you can use to override check values on either a POLICY statement in the HZSPRMxx parmlib member or on a MODIFY command. This statement may be copied and modified to override the check defaults:
UPDATE,
    CHECK(IBMSLIP,SLIP_PER),
    INTERVAL(4:00),
    SEVERITY(LOW),
    PARM(’TIME(DAYS,30)'),
    DATE(’20130901’),
    Reason(’Your reason for making the update.’)
Debug support:
No.
Verbose support:
No.
Reference:
See the SLIP command in z/OS MVS System Commands.
Messages:
This check issues the following exception messages:
  • IEAH101E
See IEAH messages in z/OS MVS System Messages, Vol 6 (GOS-IEA).
SECLABEL recommended for MLS users:
SYSLOW - see z/OS Planning for Multilevel Security and the Common Criteria for information on using SECLABELs.
End of change

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014