- Description:
- Checks that the system has connectivity to each coupling facility,
that multiple links (a/k/a CHPIDs or CFLINKs) to each coupling
facility are both ONLINE and OPERATING, and identify single points
of failure.
- Reason for check:
- To avoid single points of failure it is recommended that a
system have connectivity to each coupling facility and that there
are multiple links that are both ONLINE and OPERATIONAL.
- z/OS® releases the check
applies to:
- z/OS V1R4 and later.
- Parameters accepted:
- None.
- User override of IBM® values:
- The following shows the default keywords for the check, which
you can override on either a POLICY statement in the HZSPRMxx parmlib
member or on a MODIFY command. This statement may be copied and modified
to override the check defaults:
UPDATE CHECK(IBMXCF,XCF_CF_CONNECTIVITY)
SEVERITY(MED) INTERVAL(001:00) DATE('date_of_the_change')
REASON('Your reason for making the update.')
- Reference:
- For more information, see z/OS MVS Setting Up a Sysplex.
- Messages:
- This check issues the following exception messages:
- IXCH0446E
- IXCH0448E
- IXCH0450E
- IXCH0453E
See the IXCH messages in z/OS MVS System Messages, Vol 10 (IXC-IZP).
- SECLABEL recommended for MLS users:
- SYSLOW
|