IBM Health Checker for z/OS User's Guide
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


SDUMP_AUTO_ALLOCATION

IBM Health Checker for z/OS User's Guide
SC23-6843-02

Description:
Checks to see whether automatic allocation of SVC dump data sets is enabled.
Reason for check:
Automatic allocation of SVC dump data sets.
z/OS® releases the check applies to:
z/OS V1R4 and later.
User override of IBM® values:
The following shows the default keywords for the check, which you can override on either a POLICY statement in the HZSPRMxx parmlib member or on a MODIFY command. This statement may be copied and modified to override the check defaults:
UPDATE 
CHECK(IBMSDUMP,SDUMP_AUTO_ALLOCATION) 
SEVERITY(MEDIUM) 
INTERVAL(OneTime) 
DATE('date_of_the_change')
REASON('Your reason for making the update.') 
Parameters accepted:
No.
Reference:
For more information, see z/OS MVS Diagnosis: Tools and Service Aids.
Messages:
This check issues the following exception messages:
  • IEAH701I
  • IEAH703I
See See the IEAH messages in z/OS MVS System Messages, Vol 6 (GOS-IEA).
SECLABEL recommended for multilevel security users:
SYSLOW - see z/OS Planning for Multilevel Security and the Common Criteria for information on using SECLABELs.

Go to the previous page Go to the next page