IBM Health Checker for z/OS User's Guide
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


RSM_REAL

IBM Health Checker for z/OS User's Guide
SC23-6843-02

Description:
The REAL setting in IEASYSxx, which controls the amount of central storage that can be allocated concurrently for ADDRSPC=REAL (V=R) jobs.
Reason for check:
IBM® suggests that the REAL setting should be set to 0. However, this would not be valid if you have a need to run V=R jobs. Setting REAL=0 in IEASYSxx will improve performance.
z/OS® releases the check applies to:
z/OS V1R4 and later, in both ESA and z/Architecture® modes.
User override of IBM values:
The following shows the default keywords for the check, which you can override on either a POLICY statement in the HZSPRMxx parmlib member or on a MODIFY command. This statement may be copied and modified to override the check defaults:
UPDATE,
    CHECK(IBMRSM,RSM_REAL),
    INTERVAL(ONETIME),
    SEVERITY(LOW),
    DATE('date_of_the_change')
Parameters accepted:
No.
Reference:
For more information on real storage, see z/OS MVS Initialization and Tuning Reference.
Messages:
This check issues the following exception messages:
  • IARH101E
See the IARH messages in z/OS MVS System Messages, Vol 6 (GOS-IEA).
SECLABEL recommended for multilevel security users:
SYSLOW - see z/OS Planning for Multilevel Security and the Common Criteria for information on using SECLABELs.