IBM Health Checker for z/OS User's Guide
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


GRS_RNL_IGNORED_CONV

IBM Health Checker for z/OS User's Guide
SC23-6843-02

Description:
Searches the RESERVE Conversion RNL for entries that will be ignored because of a matching or equivalent entry in the SYSTEMS Exclusion RNL.
Reason for check:
There should be no duplicate entries between the RESERVE Conversion RNL and SYSTEMS Exclusion RNL. Duplicate entries may result in undesired serialization of a resource.
z/OS® releases the check applies to:
z/OS V1R8 and later.
Type of check:
Local
User override of IBM® values:
The following shows the default keywords for the check, which you can override on either a POLICY statement in the HZSPRMxx parmlib member or on a MODIFY command. This statement may be copied and modified to override the check defaults:
  UPDATE
  CHECK(IBMGRS,GRS_RNL_IGNORED_CONV)
  SEVERITY(LOW) INTERVAL(ONETIME) DATE(20050202)
  REASON('YOUR REASON FOR MAKING AN UPDATE.')
Debug support:
No
Verbose support:
No
Parameters accepted:
No
Reference:
For more information on Global Resource Serialization RNL’s, seez/OS MVS Planning: Global Resource Serialization.
Messages:
This check issues the following exception messages:
  • ISGH0317E
See the ISGH messages in z/OS MVS System Messages, Vol 9 (IGF-IWM).
SECLABEL recommended for multilevel security users:
SYSLOW - see z/OS Planning for Multilevel Security and the Common Criteria for information on using SECLABELs.

Go to the previous page Go to the next page