IBM Health Checker for z/OS User's Guide
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


DAE_SHAREDSN

IBM Health Checker for z/OS User's Guide
SC23-6843-02

Description:
Checks that in a sysplex environment DAE data set is shared between systems (DAE option SHARE(DSN) is in effect).

This check is only applicable for a system in a Parallel Sysplex® environment. Note, however, that this check is not applicable and will not run on a geographically dispersed Parallel Sysplex (GDPS®) controlling system (K-sys) in a GDPS environment.

Reason for check:
In a Parallel Sysplex environment, if the DAE data set is not being shared, it is possible that the system requests a dump for a problem occurred on another system in the sysplex. To prevent duplicate dumps on all systems in the Sysplex, IBM® recommends that you share the same ADYSETxx parameter values in each system.

This check will detect if the DAE data set is being shared in a Parallel Sysplex environment.

z/OS® releases the check applies to:
z/OS V1R11 and later.
Parameters accepted:
No
User override of IBM values:
The following shows the default keywords for the check, which you can override on either a POLICY statement in the HZSPRMxx parmlib member or on a MODIFY command. This statement may be copied and modified to override the check defaults:
UPDATE
CHECK(IBMDAE,DAE_SHAREDSN)
ACTIVE
SEVERITY(MED) INTERVAL(24:00) DATE('date_of_the_change')
REASON('Your reason for making the update.')
Debug support:
Reference:
For more information, see:
Messages:
This check issues the following exception messages:
  • ADYH011E
See the ADYH messages in z/OS MVS System Messages, Vol 1 (ABA-AOM).
SECLABEL recommended for MLS users:
SYSLOW

Go to the previous page Go to the next page