CEE3USR
sets or queries one of two 4-byte fields known as the user area fields.
The user area fields are associated with an enclave and are maintained
on an enclave basis. A user area field can be used by vendor or application
programs to store a pointer to a global data area or to keep a recursion
counter.
Be careful not to confuse the Language Environment user
area fields with the PL/I user
area. The PL/I user
area is a 4-byte field in the PL/I TCA
and can be accessed only through assembler language. The PL/I user
area continues to be supported for compatibility.
Language Environment initializes
both user area fields to X'00000000' during enclave initialization.
Syntax
>>-CEE3USR--(--function_code--,--field_number--,--field_value--->
>--,--fc--)----------------------------------------------------><
- function_code (input)
- A fullword binary integer representing the function performed:
- 1—SET
- User area field according to the value specified in field_value.
- 2—QUERY
- User area field; return current value in field_value.
- field_number (input)
- A fullword binary integer indicating the field to set or query. field_number must
be specified as either 1 or 2.
- field_value (input/output)
- A fullword binary integer.
If function_code is
specified as 1 (meaning SET user area field), field_value contains
the value to be copied to the user area field.
If function_code is
specified as 2 (meaning QUERY user area field), the value in the user
area field is copied to field_value.
- fc (output)
- A 12-byte feedback code, optional in some languages,
that indicates the result of this service. If you choose to omit this
parameter, refer to Invoking callable services for the
appropriate syntax to indicate that the feedback code was omitted.
The
following symbolic conditions can result from this service:
Code |
Severity |
Message number |
Message text |
---|
CEE000 |
0 |
— |
The service completed successfully. |
CEE3PS |
3 |
3900 |
The function code passed to CEE3USR was not 1 or 2. |
CEE3PT |
3 |
3901 |
The field number passed to CEE3USR was not 1 or 2. |
Usage notes - z/OS UNIX consideration—CEE3USR
applies to the enclave.
Examples - Following is an example of CEE3USR called by C/C++.
/*Module/File Name: EDC3USR */
#include <stdio.h>
#include <stdlib.h>
#include <string.h>
#include <leawi.h>
#include <ceeedcct.h>
typedef struct {
int value1,value2,value3;
char slot1_80¨;
} info_struct;
int main (void) {
_INT4 function_code, field_number, field_value;
_FEEDBACK fc;
info_struct *info;
info = (info_struct *)malloc(sizeof(info_struct));
/* .
.
. */
/* Set User field 1 to point to info_struct */
function_code = 1;
field_number = 1;
field_value = (int)info;
CEE3USR(&function_code,&field_number,&field_value,&fc);
if ( _FBCHECK ( fc , CEE000 ) != 0 ) {
printf("CEE3USR failed with message number %d\n",
fc.tok_msgno);
exit(2999);
}
/* .
.
. */
/* get the value of field 2 */
function_code = 2;
field_number = 1;
CEE3USR(&function_code,&field_number,&field_value,&fc);
if ( _FBCHECK ( fc , CEE000 ) != 0 ) {
printf("CEE3USR failed with message number %d\n",
fc.tok_msgno);
exit(2999);
}
/* .
.
. */
}
- Following is an example of CEE3USR called by COBOL.
CBL LIB,QUOTE
*Module/File Name: IGZT3USR
*************************************************
** **
** CBL3USR - Call CEE3USR to set or query user **
** area fields **
** **
** In this example, CEE3USR is called twice: **
** once to set the value of a user area, and **
** once to query it. **
** **
*************************************************
IDENTIFICATION DIVISION.
PROGRAM-ID. CBL3USR.
DATA DIVISION.
WORKING-STORAGE SECTION.
01 FUNCODE PIC S9(9) BINARY.
01 FIELDNO PIC S9(9) BINARY.
01 INVALUE PIC S9(9) BINARY.
01 FC.
02 Condition-Token-Value.
COPY CEEIGZCT.
03 Case-1-Condition-ID.
04 Severity PIC S9(4) BINARY.
04 Msg-No PIC S9(4) BINARY.
03 Case-2-Condition-ID
REDEFINES Case-1-Condition-ID.
04 Class-Code PIC S9(4) BINARY.
04 Cause-Code PIC S9(4) BINARY.
03 Case-Sev-Ctl PIC X.
03 Facility-ID PIC XXX.
02 I-S-Info PIC S9(9) BINARY.
PROCEDURE DIVISION.
*************************************************
** Specify 1 for SET function.
** Specify field number 1 to set the value field
** number 1.
** Specify 23 to make the value of field number 1
** equal to 23.
*************************************************
PARA-3USRSET.
MOVE 1 TO FUNCODE.
MOVE 1 TO FIELDNO.
MOVE 23 TO INVALUE.
CALL "CEE3USR" USING FUNCODE, FIELDNO,
INVALUE, FC.
IF NOT CEE000 of FC THEN
DISPLAY "CEE3USR failed with msg "
Msg-No of FC UPON CONSOLE
STOP RUN
END-IF.
*************************************************
** Specify 2 for QUERY function.
** Specify field number 1 to query the value
** of field number 1.
*************************************************
PARA-3USRQRY.
MOVE 2 TO FUNCODE.
MOVE 1 TO FIELDNO.
CALL "CEE3USR" USING FUNCODE, FIELDNO,
INVALUE, FC.
IF CEE000 of FC THEN
DISPLAY "User Area field " FIELDNO
" is: " INVALUE
ELSE
DISPLAY "CEE3USR failed with msg "
Msg-No of FC UPON CONSOLE
STOP RUN
END-IF.
GOBACK.
- Following is an example of CEE3USR called by PL/I.
*PROCESS MACRO;
/* Module/File Name: IBM3USR */
/****************************************************/
/** **/
/** Function: CEE3USR - set/query user area fields **/
/** **/
/** In this example, CEE3USR is called twice: once **/
/** to set the value of a user area, and once to **/
/** query it. **/
/****************************************************/
PLI3USR: PROC OPTIONS(MAIN);
%INCLUDE CEEIBMAW;
%INCLUDE CEEIBMCT;
DCL FUNCODE REAL FIXED BINARY(31,0);
DCL FIELDNO REAL FIXED BINARY(31,0);
DCL OUTVALUE REAL FIXED BINARY(31,0);
DCL INVALUE REAL FIXED BINARY(31,0);
DCL 01 FC, /* Feedback token */
03 MsgSev REAL FIXED BINARY(15,0),
03 MsgNo REAL FIXED BINARY(15,0),
03 Flags,
05 Case BIT(2),
05 Severity BIT(3),
05 Control BIT(3),
03 FacID CHAR(3), /* Facility ID */
03 ISI /* Instance-Specific Information */
REAL FIXED BINARY(31,0);
FUNCODE = 1; /* Specify 1 for the set function */
FIELDNO = 1; /* Specify field 1 of two */
INVALUE = 5; /* Value to put in field 1 */
/* Call CEE3USR to set user field 1 to 5 */
CALL CEE3USR ( FUNCODE, FIELDNO, INVALUE, FC );
IF FBCHECK( FC, CEE000) THEN DO;
PUT SKIP LIST( 'LE/370 User field ' || FIELDNO
|| ' has been set to ' || INVALUE );
END;
ELSE DO;
DISPLAY( 'CEE3USR failed with msg '
|| FC.MsgNo );
STOP;
END;
/* Call CEE3USR to query the value of field 1 */
FUNCODE = 2; /* Specify 2 for query function */
FIELDNO = 1; /* Specify field 1 of two */
CALL CEE3USR ( FUNCODE, FIELDNO, OUTVALUE, FC );
IF FBCHECK( FC, CEE000) THEN DO;
PUT SKIP LIST( 'LE/370 User field ' || FIELDNO
|| ' is currently set to ' || OUTVALUE );
END;
ELSE DO;
DISPLAY( 'CEE3USR failed with msg '
|| FC.MsgNo );
STOP;
END;
END PLI3USR;
|