The six parameters are:
- exit_type
- (Input) The address of a fullword of storage that indicates the
exit type. The value is always 4, to indicate an ADATA exit.
- action
- (Input) The address of a fullword integer that can be one of
the following three values:
- 0
- OPEN Request. Open and initialize the filter. No ADATA record is
available with this call, although there might be initial character
string data supplied.
The exit accepts the following return codes:
- 0
- The open action was successful. The exit calls the
filter module to inspect and process each ADATA record.
- 12
- The open action was unsuccessful. The filter module is assumed
to have closed itself, and is not called again.
- 1
- CLOSE Request. The exit is requesting the filter module to close
itself. No ADATA record is available with this call and no further
calls are made to the filter module.
The exit accepts the following return codes:
- 0
- The filter module has closed successfully. The exit can delete the
filter.
- 12
- The filter module is assumed to have closed itself, and is not
called again. The exit can delete the filter.
- 3
- PROCESS Request. A record is available to the filter module for
processing. The ADATA record should not be modified.
The exit accepts the following return codes:
- 0
- The filter module has completed its processing of this record, and
is ready to accept further records.
- 12
- The filter module is assumed to have closed itself, and is not
called again.
- return_code
- (Output) The address of a fullword integer where the filter
module should place a return code. Valid return codes are described
under each action.
- handle
- (Input/Output) The address of a 4-fullword area of storage that is
initialized to zero before the OPEN (action=0) call
to the filter. Its contents
are preserved across subsequent calls. The handle can be used
in any way by the filter module; for example, to address working
storage for a reenterable filter module.
- record_length
- (Input) The address of a fullword integer containing the length
of the ADATA record. A length is provided for
PROCESS (action=3) calls, and for OPEN (action=0)
calls when you supply an initial character string.
- record
- (Input) The address of the ADATA record.
This points to the ADATA record for PROCESS (action=3)
calls, and to the initial character string for
OPEN (action=0) calls.
|