z/OS DFSMShsm Implementation and Customization Guide
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


IEHMOVE utility

z/OS DFSMShsm Implementation and Customization Guide
SC23-6869-01

An incompatibility can exist between the IEHMOVE utility and DFSMShsm if the data set being moved or copied has migrated.

If the IEHMOVE utility assumes that the data set being copied or moved is cataloged, the volume serial number returned by the catalog locate for the data set must be associated with a volume allocated to the job step, or the IEHMOVE utility cannot complete the request. The IEHMOVE utility assumes that the data set is cataloged if the FROM=device=list parameter has not been specified. Also, in this case, the located volume serial number is MIGRAT. Therefore, you have to (1) use the RECALL command to recall the migrated data set, or (2) automatically recall the data set by allocating it in a previous step before running the IEHMOVE utility.

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014