Diagnosis and repair action for AUDIT COMMONQUEUE(RECALL)

The following indicate that the CRQ may be corrupted:
Note: An unexpected loss of connectivity to the CRQ may also introduce errors, but in most cases DFSMShsm automatically corrects those errors. When this occurs, you may see the multiple issuance of message ARC1102I. Message ARC1102I is issued when DFSMShsm attempts to recall a data set that has already been recalled. It is normal for this message to occur at the time of a loss of connectivity and it does not indicate a problem with the CRQ list structure.

If you believe that the CRQ has been corrupted, issue the AUDIT COMMONQUEUE(RECALL) FIX command. When this command is issued, DFSMShsm scans the entries in the CRQ and attempts to correct logical inconsistencies within the structure. AUDIT cannot correct all types of errors and may report that zero errors were detected even though there are errors in the CRQ structure.

Note: The following parameters are not used with AUDIT COMMONQUEUE:

If after issuing the AUDIT command, message ARC1506E or message ARC1187E occurs repeatedly, or certain data sets are unexpectedly not being selected for recall processing, refer toOther space management considerations for more information about correcting errors within the CRQ.