DFHZC6207 E date time applid Catalog key too long or zero. Pattern pattern
Explanation
While executing a request, CICS table builder services has detected that builder cited in the pattern pattern has returned an invalid CC key on MAKEKEY. pattern is the name of the pattern as coded in the DFHBSPTE macro.
System action
CICS rejects the request. A system dump is taken with dumpcode ZC6207. Message DFHME0116, which contains the symptom string for this problem, is produced.
User response
If you need further assistance from IBM to resolve this problem, see Working with IBM to solve your problem for guidance on how to proceed.
Module
DFHTBSBP, DFHTBSDP, DFHTBSLXMEOUT parameters/Message inserts
- date
- time
- applid
- pattern
Destination
CSMT