DFHZC0187 date time applid Reset of connection sysid failed following the ending of an affinity between this application and a remote LU with generic resource name grname member name applid. The connection was locked by task taskid, transaction tranid.

Explanation

CICS has failed to reset connection sysid after an affinity was ended successfully. A lock was held by task taskid, transaction tranid.

System action

Processing continues but the state of the connection is undetermined. The lock on the connection should be released when task taskid ends.

User response

If appropriate, use the information in the message to find out why there was a lock on the connection. If the connection is left in a state where it cannot be acquired, delete and reinstall it.

Module

DFHZGCH

XMEOUT parameters/Message inserts

  1. date
  2. time
  3. applid
  4. sysid
  5. grname
  6. applid
  7. taskid
  8. tranid

Destination

CSNE