DFHZC0167 date time applid termid An attempt to sign off a user at termid termid failed following a multinode persistent sessions restart. Response code rc1 and reason code rc2 were received.
Explanation
CICS attempted to sign off a user at termid termid because of a signon timeout following a multinode persistent sessions restart. An exception or disaster response was received from the signon program DFHSNTU with one of the following reason codes:
- Reason code
- Explanation
- 002
-
There is no active ESM.
- 003
-
The ESM is not responding.
- 010
-
The terminal type is invalid for this operation.
- 017
-
The terminal has preset security.
- 019
-
Security is not active for this CICS.
- 022
-
The terminal is a surrogate terminal.
- 028
-
The ESM returned a response which was not recognized by the CICS security domain.
- 038
-
The signon program went into recovery following an ABEND.
- 048
-
The signon program detected a loop and went into recovery.
- 052
-
The signon program received a bad response from transaction manager.
System action
An AP exception trace with point ID FB9D is issued.
User response
Reason codes 002, 003, 019 and 028 indicate a problem with the ESM or the security domain. The remaining reason codes may indicate an internal error in CICS. Look for messages output earlier by the ESM or the security domain. If security was active when the problem occurred and there was no problem with the ESM or the security domain contact your IBM support center.
Module
DFHZSGNXMEOUT parameters/Message inserts
- date
- time
- applid
- termid
- termid
- rc1
- rc2
Destination
CSNE