DFHZC0111 date time applid No session TCTTE is available to match sysid sysid for modename modename because VTAM has returned more NIBs than the CNOS session limit values require.
Explanation
During persistent sessions restart VTAM has returned more node initialization blocks (NIBs) than the current CNOS session limit values require. This is probably because a CNOS from a high session limit to a lower session limit was in progress when CICS failed.
System action
The process NIB function is terminated. The session is unbound. CICS ignores this session and continues with the next session if there is one.
This situation has no effect on the restored CICS. The last catalogued CNOS values are restored.
User response
None.
Module
DFHZGPCXMEOUT parameters/Message inserts
- date
- time
- applid
- sysid
- modename
Destination
CSNE