Inquire CF Structure Status
The Inquire CF Structure Status (MQCMD_INQUIRE_CF_STRUC_STATUS) command inquires about the status of a CF application structure.
HP Integrity NonStop Server | IBM® i | UNIX and Linux® | Windows | z/OS® |
---|---|---|---|---|
Required parameters
CFStrucName
(MQCFST)- CF Structure name (parameter identifier: MQCA_CF_STRUC_NAME).
Specifies the name of the CF application structure for which status information is to be returned.
Generic CF structure names are supported. A generic name is a character string followed by an asterisk (*), for example ABC*, and it selects all CF application structures having names that start with the selected character string. An asterisk on its own matches all possible names.
The maximum length is MQ_CF_STRUC_NAME_LENGTH.
Optional parameters
CFStatusType
(MQCFIN)- Status information type (parameter identifier: MQIACF_CF_STATUS_TYPE).
Specifies the type of status information you want to be returned. You can specify one of the following:
- MQIACF_CF_STATUS_SUMMARY
- Summary status information for the CF application structure. MQIACF_CF_STATUS_SUMMARY is the default.
- MQIACF_CF_STATUS_CONNECT
- Connection status information for each CF application structure for each active queue manager.
- MQIACF_CF_STATUS_BACKUP
- Backup status information for each CF application structure.
- MQIACF_CF_STATUS_SMDS
- Shared message data set information for each CF application structure.
IntegerFilterCommand
(MQCFIF)- Integer filter command descriptor. The parameter identifier must be any integer type parameter in the response data except MQIACF_CF_STATUS_TYPE.
Use this parameter to restrict the output from the command by specifying a filter condition. See MQCFIF - PCF integer filter parameter for information about using this filter condition.
If you specify an integer filter, you cannot also specify a string filter using the
StringFilterCommand
parameter. StringFilterCommand
(MQCFSF)- String filter command descriptor. The parameter identifier must be any string type parameter in the response data except MQCA_CF_STRUC_NAME.
Use this parameter to restrict the output from the command by specifying a filter condition. See MQCFSF - PCF string filter parameter for information about using this filter condition.
If you specify a string filter, you cannot also specify an integer filter using the
IntegerFilterCommand
parameter.