Start of change

DSNT043I   DSNTRVFY - THE WLM APPLICATION ENVIRONMENT IS SHARED WITH ANOTHER ROUTINE THAT HAS A DIFFERENT SECURITY REQUIREMENT

Explanation

The following DB2®-supplied routines requires RACF® program control if the BPX.DAEMON facility class is active. If the BPX.DAEMON is active and one of the programs loaded into the WLM address space where these DB2-supplied routines are running is not defined to program control then an error will be returned by the routine indicating that the operation is not permitted.

  • SYSPROC.ADMIN_COMMAND_UNIX
  • SYSPROC.ADMIN_JOB_CANCEL
  • SYSPROC.ADMIN_JOB_FETCH
  • SYSPROC.ADMIN_JOB_QUERY
  • SYSPROC.ADMIN_JOB_SUBMIT
  • SYSPROC.ADMIN_UTL_MONITOR

System action

Processing continues.

User response

Determine if the BPX.DAEMON is active. If BPX.DAEMON is not active, no action is required.

If it is active, ensure that all programs that have been loaded into the WLM address space where these routines are defined are controlled by RACF. Refer to the DSNTIJRA job, which provides the commands for defining programs to RACF program control.

Severity

4 (warning)

End of change