HSL Opticonnect abnormal disconnect from other sys. or partition.
Response
The local system or partition disconnected from a remote
system or partition due to an unexpected event or failure.
LIC will attempt to recover from the error. Intervention
at the local or remote system or partition may be required.
Possible causes are: time out, hang or hardware failure.
The problem may be with: the local system or partition or
the remote system or partition.
If there was not a complete HSL loop before this error
then a failure or power down in an HSL component
between the local system or partition and the remote system
or partition could have caused this error. Check for SRCs
with FRUs like: HSL cables, HSL I/O bridge or
a power problem in an expansion I/O tower or unit on this
loop.
Examine the SAL or serviceable event view you are
working with on the local system or
partition for failures on the same loop, or with the
Network Interface Controller at approximately the same time.
Examine the remote system or partition for problems.
Correct any HSL or NIC problems you find with the remote and
local
systems or partitions.
If there are no problems with the remote system or partition
and there are no problems with the local system or partition
then collect all the Product Activity Log (PAL)
information for
this failure on both systems. Be sure to record all words in
the SRC. Contact your next level of support.