For Power5 and newer servers, service this error using the B7006986
service information. Otherwise, continue with this information.
During IPL, system LIC detected an HSL I/O bridge that was
already initialized. The bridge should have been in a
flushed and
uninitialized state after powering on. There is a problem
with SPCN components that prevented the tower from powering
off after a previous power off was issued. The tower will
not be configured
for this IPL.
This reference code is equivalent to 1xxx 90F0. When
referring to the "CBLALL" symbolic FRU in the Failing Item
list, perform the "CBLALL" procedure using reference code
"90F0".
Word 5 of the SRC identifies the frame. Determine the frame
by breaking down word 5:
Word 5 -> xxxx xxNN where: NN is the frame number in
hexadecimal format.