A6006983

Explanation

A High Speed Link (HSL) / RIO / 12X loop configuration event was detected. The loop may have an unsupported configuration or a configuration that is not valid or the loop is in a state that LIC is logging for potential future reference.

Problem determination

LIC is reporting an event about the state of a RIO / HSL / 12X loop. Word 4 of the SRC contains the program return code (PRC) which. identifies the state or problem with the loop.

For Power5 and newer servers, if this event appears in a serviceable event view then a service action is required. This SRC may also be logged as informational when it is recording information about the loop that is not a problem for the LPAR.

If this event does not appear in a serviceable event view then no service is required. To determine what the event meaning is record the PRC in word 4 of the SRC then use symbolic FRU SIRGCFG. This completes the procedure.

If this event appears in a serviceable event view then search for a B7006983 serviceable event logged at about the same time.

Did you find a B7006983 serviceable event logged at about the same time in the LPAR?
  • YES - Service this error by working the B7006983 error.
  • NO - Continue working this SRC. If you are using the Service Action Log (SAL) the FRU description may already indicate the configuration problem. Otherwise record the PRC in word 4 of the SRC. Use symbolic FRU SIRGCFG to determine the problem.

Failing Item