High Speed Link (HSL) or PCI bridge card slot I/O bridge failure.
Response
For Power5 and newer servers, service this error using the B7006981
service information. Otherwise, continue with this information.
Cycle power on the frame identified as the frame with failed
HSL I/O Bridge prior to replacing FRUs.
The FRU list displayed in the Service Action Log
(SAL), or serviceable event view you are using, may
vary from the failing item list given in this document. Use
the FRU list in the serviceable event view if it is
available to you.
If you find either a B6xx 6982 or B6xx 6984 SRC logged at
approximately the same time as this SRC then they were
caused by the same failure. If you find a 6982 SRC logged
at approximately the same time then close this problem and
service
the 6982 SRC. The failing item listed for this SRC
is one of the failing items listed for B6xx 6982. If the
serviceable event view's entry for this SRC has a location
listed
then record the location for use in servicing the 6982 SRC.
NOTE: This SRC can occur for the HSL I/O Bridge resource in
an I/O expansion unit when the unit is powered off for a
concurrent maintenance action.
NOTE: A fiber optic cleaning kit may be required for optical
HSL connections.