Use this procedure to replace the concurrent maintainable
battery pack on adapter type CCIN 57B7.
Complete the following steps to replace a 57B7 concurrent
maintainable battery pack.
- Using the following illustration to locate the battery
components, verify that the cache data present LED (C) is
not flashing. If it is flashing, do not continue; return
to Forcing a rechargeable battery error.
- Move the cache battery lever (A) away
from the connector to disengage the battery from the connector.
- Continue to slide the cache battery pack out
of the mounting guides and remove it from the controller.
Note: Ensure
that the cache battery pack is disconnected for at least 60 seconds
before connecting the new battery. This duration is the minimum amount
of time needed for the card to recognize that the battery has been
replaced.
- Using the following illustration to locate the
battery components, move the lever to the unlatched position (away
from the connector).
- (A) Cache battery lever
- (B) Cache battery pack
- (C) Cache battery connector
- Slide the new cache battery pack into the mounting
guides on the controller until it is seated in the battery connector.
- After the battery is seated in the connector,
move the lever to the latched position to fully seat the battery into
the connector.
- Restart the adapter's write cache by doing
the following:
- Return to the Work with Resources containing
Cache Battery Packs display and select the Start
IOA cache. Press Enter.
- Ensure that you get the message Cache was started.