Use this procedure to replace the concurrent maintainable
battery pack on adapter type CCIN 572F/575C card set.
Complete the following steps to replace a 572F/575C concurrent
maintainable battery pack.
- Using the following illustration to locate the battery's
components, locate the metal cover A that
holds the battery pack. Pull out on the push-rivet B to
release the metal cover A .
Figure 1. Replacing the 572F/575C cache battery
- A Metal cover
- B Push-rivet
- C Tab
- Remove the battery unit by pulling on tab C .
Note: Ensure that the cache battery pack is disconnected for
at least 60 seconds before connecting the new battery. This is the
minimum amount of time needed for the card to recognize that the battery
has been replaced.
- Install the new cache battery pack by reversing this procedure.
Ensure that the replacement cache battery pack is fully seated.
- Restart the adapter's write cache by performing the following
steps:
- Navigate to the IBM® SAS Disk Array Manager by
using the steps in Using the Disk Array Manager.
- Select Diagnostics and Recovery Options.
- Select Controller Rechargeable Battery Maintenance.
- Select Start Adapter Cache.
- Select the controller with the battery you just replaced.
- Press Enter.