(B1xx) Service processor firmware reference code descriptions

If you wish to determine if the SRC requires a service action or if it is for tracking purposes only, see (B1xx) Service processor firmware reference codes for instructions.

Note: See Table 2. (B1xx) SRC Descriptions for a list of B1xx SRCs and descriptions.

B1xxyyyy where:

xx=
Indicates the subsystem where the event or error occurred. See Table 1. (B1xx) Service processor subsystem IDs.
yyyy=
The reason for the event or error (reason code). See Table 3. (B1xx) Service processor reason codes' ranges.

A B1xx reference code indicates that an event or exception occurred in a service processor firmware-detected operation. The following tables describe the B1xx SRCs.

Table 1. (B1xx) Service processor subsystem IDs

Subsystem ID Description
10 Processor subsystem event or error reported by the service processor.
11 Processor FRU event or error reported by the service processor.
12 Processor chip (including internal cache) event or error reported by the service processor.
13 Processor unit (CPU) event or error reported by the service processor.
14 Processor/system bus controller and interface event or error reported by the service processor.
20 Memory subsystem event or error reported by the service processor.
21 Memory controller event or error reported by the service processor.
22 Memory bus interface event or error reported by the service processor.
23 Memory DIMM event or error reported by the service processor.
24 Memory card/FRU event or error reported by the service processor.
25 External cache event or error reported by the service processor.
30 I/O subsystem event or error reported by the service processor.
31 I/O hub (Remote I/O) event or error reported by the service processor.
32 I/O bridge event or error reported by the service processor.
33 I/O bus interface event or error reported by the service processor.
34 I/O processor event or error reported by the service processor.
35 SMA hub event or error reported by the service processor.
36 Remote I/O loop and associated I/O hub event or error reported by the service processor.
37 Remote I/O loop and associated I/O bridge event or error reported by the service processor.
38 Processor Host Bridge (PHB) event or error reported by the service processor.
39 EADS/EADS-X global event or error reported by the service processor.
3A EADS/EADS-X slot event or error reported by the service processor.
40 I/O adapter event or error reported by the service processor.
46 I/O device event or error reported by the service processor.
50 System unit hardware event or error reported by the service processor.
51 Service processor event or error reported by the service processor.
55 VPD device and interface event or error reported by the service processor.
56 I2C device and interface event or error reported by the service processor.
57 JTAG device and interface event or error reported by the service processor.
58 Clock and control event or error reported by the service processor.
59 Control panel event or error reported by the service processor.
5A Time-of-day hardware (including the battery) event or error reported by the service processor.
5B Storage/memory device on service processor event or error reported by the service processor.
60 Power/cooling subsystem and control event or error reported by the service processor.
61 Power supply event or error reported by the service processor.
62 Power control hardware event or error reported by the service processor.
63 Fan or other air moving device event or error reported by the service processor.
70 Other event or error reported by the service processor.
71 HMCHMC subsystem and hardware event or error reported by the service processor.
72 Test tool event or error reported by the service processor.
73 Removal media event or error reported by the service processor.
74 Multiple subsystems event or error reported by the service processor.
75 Unknown, invalid event or error reported by the service processor.
76 Informational event reported by the service processor.
7B Connection monitoring error: service processor lost communication with the server firmware.
7C Connection monitoring error: service processor lost communication with the HMCHMC.
7D Connection monitoring error: HMCHMC lost communication with a logical partition.
80 Platform firmware event or error reported by the service processor.
81 Service processor firmware event or error reported by the service processor.
82 Server firmware event or error reported by the service processor.
85 SPCN firmware event or error reported by the service processor.
86 Bulk power firmware event or error reported by the service processor.
87 HMCHMC code or firmware event or error reported by the service processor.
90 Software event or error reported by the service processor.
A0 External environment event or error reported by the service processor
A1 Input power source (AC) event or error reported by the service processor.
A2 Room (ambient) temperature event or error reported by the service processor.
A3 User error reported by the service processor.

Table 2. (B1xx) SRC Descriptions

Reference Code Description Action
B103F684 Xscoms are not supported Determine if service action or tracking event
B104FAA9 Failed trying to get pointer to functional unit group for type Determine if service action or tracking event
B110E500 Bad hardware Determine if service action or tracking event
B110F138 Scom attention detected on the current chip Determine if service action or tracking event
B110F139 Master Attention Alone detected Determine if service action or tracking event
B110F141 Indicates a potential problem with clock card Determine if service action or tracking event
B110F7B0 The interposer plug count for the MCM in the callout has exceeded the limit Determine if service action or tracking event
B110F7B1 The interposer plug count for the MCM in the callout has exceeded the limit Determine if service action or tracking event
B110F7B2 The interposer plug count for the MCM in the callout has exceeded the limit Determine if service action or tracking event
B110F7B3 The interposer plug count for the MCM in the callout has exceeded the limit Determine if service action or tracking event
B110F7B4 The interposer plug count for the MCM in the callout has exceeded the limit Determine if service action or tracking event
B110F7B5 The interposer plug count for the MCM in the callout has exceeded the limit Determine if service action or tracking event
B110F7B6 The interposer plug count for the MCM in the callout has exceeded the limit Determine if service action or tracking event
B110F7B7 The interposer plug count for the MCM in the callout has exceeded the limit Determine if service action or tracking event
B111E500 Bad hardware Determine if service action or tracking event
B111F64B Fabric latency calculation packet not received on processor Determine if service action or tracking event
B111F658 Invalid fabric rotation length Determine if service action or tracking event
B111F665 Processor's POR State Machine not at idle after free running logic reset Determine if service action or tracking event
B112E500 Bad hardware Determine if service action or tracking event
B112F64E PLL Health check failed on Trimaran Determine if service action or tracking event
B112F65B Invalid L2 Slice Configuration Determine if service action or tracking event
B112F66E Handling CE detected by the fabric firs and the L3 firs Determine if service action or tracking event
B112F66F Handle errors detected by L3 firs and the ebist engine Determine if service action or tracking event
B112F670 Handle CE detected by L3 firs Determine if service action or tracking event
B113E500 Bad hardware Determine if service action or tracking event
B114E500 Bad hardware Determine if service action or tracking event
B114F2DF Fatal IAP Error Determine if service action or tracking event
B114F663 Fabric initialization failed on processor Determine if service action or tracking event
B114F66C Clock period from Fabric out of calculated range Determine if service action or tracking event
B114F66D Operation attempted on nonfunctional Functional unit Determine if service action or tracking event
B114F66E Handling CE detected by the Fabric firs and the L3 firs Determine if service action or tracking event
B114F6A1 Processor chip didn't have all zeros in the ring scanned Determine if service action or tracking event
B114F6A2 Processor chip didn't have all ones in the ring scanned Determine if service action or tracking event
B114F6C1 Actual Processor chip lbist signature didn't match the expected values Determine if service action or tracking event
B114F6D0 Processor chip abist timeout Determine if service action or tracking event
B114F6D1 Processor chip abist fail Determine if service action or tracking event
B114F6D2 Processor chip missing fusemap data in VPD Determine if service action or tracking event
B114F6D3 No repairs found for pending array repair Determine if service action or tracking event
B114F7A4 Processor gets clock errors with each clock input Determine if service action or tracking event
B114FB53 Wiretest has detected an EST error Determine if service action or tracking event
B120E500 Bad hardware Determine if service action or tracking event
B120F228 A memory block trying to be referenced is out of range Determine if service action or tracking event
B120F667 Fir bit UE (uncorrectable error) during maintenance scrub or L3 connections test display Determine if service action or tracking event
B120F685 Single-shot command never completed Determine if service action or tracking event
B121E500 Bad hardware Determine if service action or tracking event
B121F2DF Undetermined failure on IAP Determine if service action or tracking event
B121F666 Fir bit indicates problem with memory controller Determine if service action or tracking event
B121F66A Cache line write buffer CEs after a flush if Manufacturing mode set Determine if service action or tracking event
B121F66B No fir bits on. Maintenance command timed out Determine if service action or tracking event
B121F66E Handling CE detected by the Fabric firs and the L3 firs Determine if service action or tracking event
B121F684 This level of hardware does not support 8GB DIMMs that require ranks 8-15 Determine if service action or tracking event
B121F690 Fir bit indicates MC CE Determine if service action or tracking event
B121F7A5 The memory controller gets clock errors with both clock inputs Determine if service action or tracking event
B123E500 Bad hardware Determine if service action or tracking event
B123F642 The DIMMs in the callout list are part of an incomplete group because of missing DIMMs Determine if service action or tracking event
B123F643 The DIMMS in the callout list don't match, so they form an invalid memory group Determine if service action or tracking event
B123F667 Fir bit UE (uncorrectable error) during maintenance scrub or L3 connections test display Determine if service action or tracking event
B123F669 Maintenance CE threshold exceeded during maintenance scrub or L3 connections test display Determine if service action or tracking event
B123F688 The DIMMS in the callout list are on a processor card that only allows quad stacked DIMMs Determine if service action or tracking event
B123F7BB The system resource(s) in the callout list failed a system configuration test Determine if service action or tracking event
B124E500 Bad hardware Determine if service action or tracking event
B124F622 Failed JTAG function call Determine if service action or tracking event
B124F62A POR Complete not reached on SMI2. Chip is most likely locked up Determine if service action or tracking event
B124F64E PLL Lock Failure (PLL is unlocked) Determine if service action or tracking event
B124F65F SMI didn't exit power down mode after Exit Power Down maintenance command executed Determine if service action or tracking event
B124F66C Clock period from SMI out of calculated range Determine if service action or tracking event
B124F68D Fir bit indicates problem with SP code or SMI Determine if service action or tracking event
B124F68E Fir bit indicates interface problem with DIMMs Determine if service action or tracking event
B124F68F Fir bit indicates interface CEs with DIMMs Determine if service action or tracking event
B124F690 Fir bit indicates MC CE Determine if service action or tracking event
B124F691 SMI Masked Fir Bit On Determine if service action or tracking event
B124F6C7 SMI2 lbist signature didn't match the expected values Determine if service action or tracking event
B125E500 Bad hardware Determine if service action or tracking event
B125F622 Failed JTAG function call Determine if service action or tracking event
B125F62A Timed out waiting for Trimaran LBIST to complete Determine if service action or tracking event
B125F66C Clock period from Trimaran out of calculated range Determine if service action or tracking event
B125F66E Handling CE detected by the Fabric firs and the L3 firs Determine if service action or tracking event
B125F66F Handle errors detected by L3 firs and the ebist engine Determine if service action or tracking event
B125F670 Handle CE detected by L3 firs Determine if service action or tracking event
B125F671 Trimaran not ready for ebist Command Determine if service action or tracking event
B125F6A7 Trimaran didn't pass setting the ring to all zeros Determine if service action or tracking event
B125F6A8 Trimaran didn't pass setting the ring to all ones Determine if service action or tracking event
B125F6C4 Trimaran lbist signature didn't match the expected values Determine if service action or tracking event
B125FAA1 Ebist engine timed out Determine if service action or tracking event
B125FAA5 L3 Address to be deleted Determine if service action or tracking event
B125FAA7 Error detected by EBIST engine Determine if service action or tracking event
B130E500 Bad hardware Determine if service action or tracking event
B130F2DF Fatal IAP Error Determine if service action or tracking event
B131F138 Scom attention detected on the current chip Determine if service action or tracking event
B131E500 Bad hardware Determine if service action or tracking event
B131F242 The part found in RID location is not supported in this configuration Determine if service action or tracking event
B131F2DF Fatal IAP Error Determine if service action or tracking event
B131F64B Auto TLAR calculation failed. Acknowledge never received Determine if service action or tracking event
B131F64E PLL Lock Failure (PLL is unlocked) Determine if service action or tracking event
B131F657 Galaxy scom operation did not complete Determine if service action or tracking event
B131F66C Clock period from chip out of calculated range Determine if service action or tracking event
B131F6A3 Enterprise scanned ring to all 0 test failed Determine if service action or tracking event
B131F6A4 Enterprise scanned ring to all 1 test failed Determine if service action or tracking event
B131F6AF P5IOC scanned ring to all 0 test failed Determine if service action or tracking event
B131F6B0 P5IOC scanned ring to all 1 test failed Determine if service action or tracking event
B131F6C2 Actual Enterprise chip lbist signature didn't match the expected values Determine if service action or tracking event
B131F6C9 Actual P5IOC chip lbist signature didn't match the expected values Determine if service action or tracking event
B131F6D4 Enterprise failed abist test Determine if service action or tracking event
B131F6DA P5IOC failed abist test Determine if service action or tracking event
B132E500 Bad hardware Determine if service action or tracking event
B132F6A5 Winnipeg didn't pass the scan test of all zeros Determine if service action or tracking event
B132F6A6 Winnipeg didn't pass the scan test of all ones Determine if service action or tracking event
B132F6C3 Actual Winnipeg chip lbist signature didn't match the expected values Determine if service action or tracking event
B132F6D5 Winnipeg didn't pass abist test Determine if service action or tracking event
B132F7A8 Failed to enable host PCI Determine if service action or tracking event
B132F7A9 Failed to verify host PCI Determine if service action or tracking event
B133E500 Bad hardware Determine if service action or tracking event
B135E500 Bad hardware Determine if service action or tracking event
B135F62A We timed out waiting for the PLLs to lock Determine if service action or tracking event
B135F6C6 CanopusPlus didn't pass setting the ring to all zeros or ones ring Determine if service action or tracking event
B135F6C8 LDC lbist signature didn't match the expected values Determine if service action or tracking event
B135F6D8 CanopusPlus abist test failed Determine if service action or tracking event
B1431583 Failed to get input buffer from SCED Determine if service action or tracking event
B1503517 Failed to determine system type Determine if service action or tracking event
B150355A Error in determining FSP-A/B position Determine if service action or tracking event
B150355B Error in determining FSP-A/B position Determine if service action or tracking event
B15035D5 Failed to close I2C ADAL Determine if service action or tracking event
B150D133 Server process failed Determine if service action or tracking event
B150E500 Bad hardware Determine if service action or tracking event
B150E670 Error in determining system type. We cannot determine system type because gpio read gave unsupported values Determine if service action or tracking event
B150E675 Failed to open I2C ADAL Determine if service action or tracking event
B150E676 Failed to transmit data using I2C ADAL Determine if service action or tracking event
B150E678 Failed to obtain control of MUX Determine if service action or tracking event
B150E679 Failed to setup I2C ADAL configuration Determine if service action or tracking event
B150E67A Failed to obtain control of MUX Determine if service action or tracking event
B150E67B Failed to close I2C ADAL Determine if service action or tracking event
B150E67C Failed to receive data from I2C ADAL Determine if service action or tracking event
B150E67D Failed to transmit data using I2C ADAL Determine if service action or tracking event
B150E67E Failed to transmit data using I2C ADAL Determine if service action or tracking event
B150E67F Failed to receive data from I2C ADAL Determine if service action or tracking event
B150E680 Failed to setup GPIO pins Determine if service action or tracking event
B150E681 Failed to read GPIO pins Determine if service action or tracking event
B150E691 Failed to close I2C ADAL Determine if service action or tracking event
B150F12C Unmatched CRC Determine if service action or tracking event
B150F206 There is a card in the system that is missing or has corrupted VPD data Determine if service action or tracking event
B150F207 Detected a card in the system without chips Determine if service action or tracking event
B150F20A Failed to create daughter card object Determine if service action or tracking event
B150F22A There was not enough functional nodes found in the system to continue IPLing. Determine if service action or tracking event
B150F2C2 Fabric bus lost synchronization, IPL cannot continue Determine if service action or tracking event
B150F2DE Elastic Interface Alignment Procedure never completed Determine if service action or tracking event
B150F2DF Fatal IAP Error Determine if service action or tracking event
B150F2E0 Non-fatal IAP Error/Warning Determine if service action or tracking event
B150F2E7 There is a checkstop present prior to running FOCR Sync Determine if service action or tracking event
B150F239 Detected a missing chip Determine if service action or tracking event
B150F244 It seems that both clock cards, which should be present in the system, are not present in the system Determine if service action or tracking event
B150F620 Invalid bits set Determine if service action or tracking event
B150F627 Error detected while waiting for Trimaran display to complete Determine if service action or tracking event
B150F62A Timeout while waiting for display to complete Determine if service action or tracking event
B150F66D Handle errors detected by the Fabric firs and the L3 firs Determine if service action or tracking event
B150F805 Functional Unit procedure error Determine if service action or tracking event
B150F806 Procedure error Determine if service action or tracking event
B150F80e Error while stopping Core clocks Determine if service action or tracking event
B150F80f Error while stopping Fabric clocks Determine if service action or tracking event
B150F810 Error while starting Core clocks Determine if service action or tracking event
B150F811 Error while starting Fabric clocks Determine if service action or tracking event
B150F819 Error while reading data in from ring buffer or alias Determine if service action or tracking event
B150F81a Error while writing ring buffers or alias to hardware Determine if service action or tracking event
B150F81c Error reading from register Determine if service action or tracking event
B150F81d Error writing to register Determine if service action or tracking event
B150FAA2 Data Miscompare found in L3 Connections test but no Fir bit on Determine if service action or tracking event
B150FB53 Wiretest has detected an EST error Determine if service action or tracking event
B150FB54 RDT has detected a hardware error Determine if service action or tracking event
B150FB55 Processor group pointer is NULL Determine if service action or tracking event
B150FB61 Processor group pointer is NULL Determine if service action or tracking event
B150FB64 Processor group pointer is NULL Determine if service action or tracking event
B150FD00 GARD Actions were performed on all items that were marked to be gard'd by the system that are not resource recoverable Determine if service action or tracking event
B150FD01 GARD Actions were performed on all items that were marked as gard'd manually via the menus or system gard'd items that can be resource recovered Determine if service action or tracking event
B150FD02 GARD Data did not exist because either it was the first IPL on this machine or NVRAM had been cleared Determine if service action or tracking event
B1513598 Garding out FSPA due to communication fail Determine if service action or tracking event
B151E40A Detected DRAM Recovered Errors Determine if service action or tracking event
B151E40B Detected NVRAM Recovered Errors Determine if service action or tracking event
B1523592 Sibling FSP is expected but not present Determine if service action or tracking event
B1523599 Garding out FSPB due to communication fail Determine if service action or tracking event
B1551300 First level of basic input parameter validation failed Determine if service action or tracking event
B1551301 Second level of basic input parameter validation failed Determine if service action or tracking event
B1551304 Machine model invalid Determine if service action or tracking event
B1551305 Invalid offset type received in structure Determine if service action or tracking event
B1551306 Number of devices is less than or equal to zero Determine if service action or tracking event
B1551307 Can't open device list file Determine if service action or tracking event
B1551308 Data pointer is NULL Determine if service action or tracking event
B1551310 Failed to read root path from registry Determine if service action or tracking event
B1551311 Failed to read device path from registry Determine if service action or tracking event
B1551312 Read sink path failed Determine if service action or tracking event
B1551313 Read check value failed Determine if service action or tracking event
B1551320 No data returned from ADAL Determine if service action or tracking event
B1551321 Maximum arbitration retries exceeded Determine if service action or tracking event
B1551322 Error from the ADAL trying to set the device Master timeout Determine if service action or tracking event
B1551323 Write to old hub failed Determine if service action or tracking event
B1551324 Failed VPD dataport read Determine if service action or tracking event
B1551325 Failed VPD dataport write Determine if service action or tracking event
B1551326 Pass through to open file Determine if service action or tracking event
B1551330 Failed to release I2C lock Determine if service action or tracking event
B1551331 Failed to unlock I2C hub Determine if service action or tracking event
B1551332 Error unlocking hub Determine if service action or tracking event
B1551333 Error from ADAL trying to unlock the device behind the hub Determine if service action or tracking event
B1551334 Error unlocking CHUNKY device Determine if service action or tracking event
B1551340 Invalid operation type received in structure Determine if service action or tracking event
B1551341 Invalid number of nodes received in structure Determine if service action or tracking event
B1551342 Busy condition Determine if service action or tracking event
B1551343 Lock on first address of the chunky device failed Determine if service action or tracking event
B1551344 Error locking CHUNKY device Determine if service action or tracking event
B1551345 Error from ADAL trying to set the Master timeout Determine if service action or tracking event
B1551346 Failed to get hub type Determine if service action or tracking event
B1551350 Could not get the bus to start the transaction Determine if service action or tracking event
B1551351 Error trying to close the bus Determine if service action or tracking event
B1551352 Error from the ADAL trying to park the I2C mux Determine if service action or tracking event
B1551353 Error from ADAL trying to set Master timeout value Determine if service action or tracking event
B1551354 Error from ADAL trying to set device timeout value Determine if service action or tracking event
B1551355 Error from ADAL trying to lock the device behind the hub Determine if service action or tracking event
B1551356 Attempt to lock this device failed Determine if service action or tracking event
B1551357 Failed to set I2C lock Determine if service action or tracking event
B1551358 Error trying to set the bus speed in preparation for a retry Determine if service action or tracking event
B1551359 Error trying to read the maximum memory size of the device from the ADAL Determine if service action or tracking event
B155135A Error trying to read the bus speed to see if it can be lowered for a retry Determine if service action or tracking event
B155135B Write to set new hub failed Determine if service action or tracking event
B1551360 Write to new hub failed Determine if service action or tracking event
B1551361 Write to set the device failed Determine if service action or tracking event
B1551362 Write to set old hub failed Determine if service action or tracking event
B1551363 Retry at lower bus speed also failed Determine if service action or tracking event
B1551364 Retry after the bus reset still failed Determine if service action or tracking event
B1551365 Retry after bus busy condition still failed Determine if service action or tracking event
B1551366 Retry after loss of arbitration failed Determine if service action or tracking event
B1551370 Receive from device failed Determine if service action or tracking event
B1551371 Read from device failed Determine if service action or tracking event
B1551372 Failed to receive data from hub Determine if service action or tracking event
B1551373 Failed to receive data Determine if service action or tracking event
B1551380 Error trying to write register to device Determine if service action or tracking event
B1551381 Error trying to do the read Determine if service action or tracking event
B1551390 Error trying to reset bus Determine if service action or tracking event
B1551392 Error while closing an I2C bus or unlocking an I2C device or parking an I2C MUX Determine if service action or tracking event
B1551393 Failed to create network client address Determine if service action or tracking event
B1551394 Failed network connection between client and server Determine if service action or tracking event
B1551395 Communication error while trying to send or receive Determine if service action or tracking event
B1551396 Failed to unflatten server error log Determine if service action or tracking event
B1551397 Failed to close network client Determine if service action or tracking event
B1551398 Invalid input received from the caller Determine if service action or tracking event
B1551399 Error while trying to unflatten the server error log Determine if service action or tracking event
B155139A Error while trying to unflatten the server error log Determine if service action or tracking event
B155139B Failed to turn on FRONT light strip Determine if service action or tracking event
B155139C Failed to turn on BACK light strip Determine if service action or tracking event
B155B006 Failed to update the Module VPD Determine if service action or tracking event
B155B017 Keyword can not be found in the VPD buffer Determine if service action or tracking event
B155B028 We failed trying to read smart chip block Determine if service action or tracking event
B155B02C There was a failure trying to update one of the smart chip blocks Determine if service action or tracking event
B155B036 We failed trying to get smart chip block size Determine if service action or tracking event
B155B03D Failed to write to I2C device Determine if service action or tracking event
B155B03E Error reading from the device Determine if service action or tracking event
B155B03F Reading thermal sensor data or RIO cable id failed for the given FRU Determine if service action or tracking event
B155B048 ECC check failed on the given FRU Determine if service action or tracking event
B155B04D Checksum in the VPD data does not match calculated checksum Determine if service action or tracking event
B155B058 The VPD data which describes the wiring path of a FRU is invalid Determine if service action or tracking event
B155B05E No valid copy of System VPD was found on this system Determine if service action or tracking event
B155B060 There was a mismatch in VINI record for primary and redundant root node VPD Determine if service action or tracking event
B155B061 Unable to use either VPD Chip because we could not reach them or they are garded out Determine if service action or tracking event
B155B065 Reading all blocks from smart chip failed Determine if service action or tracking event
B155B06D Failed to process VPD chip Determine if service action or tracking event
B155B06F No valid copy of Enclosure VPD was found on this system Determine if service action or tracking event
B155B070 Invalid/Un-Programmed System Serial Number (SE) Determine if service action or tracking event
B155B071 Invalid/Un-Programmed Serial Number in Enclosure Determine if service action or tracking event
B155B072 Invalid/Un-Programmed System Storage Serial Number (SG) Determine if service action or tracking event
B155B073 Invalid/Un-Programmed System Type Model (TM) Determine if service action or tracking event
B155B074 Invalid/Un-Programmed System Storage Type Model (TN) Determine if service action or tracking event
B155B075 Invalid/Un-Programmed System Manufacturing ID (MN) Determine if service action or tracking event
B155B076 Invalid/Un-Programmed System ID (ID) Determine if service action or tracking event
B155B077 Invalid/Un-Programmed System Unique ID (SU) Determine if service action or tracking event
B155B078 Invalid/Un-Programmed World Wide Node Name (NN) Determine if service action or tracking event
B155B079 Invalid/Un-Programmed System Brand (BR) Determine if service action or tracking event
B155B07D Invalid/Un-Programmed Feature Code in Enclosure Determine if service action or tracking event
B155B083 Pin failure failed after root node mismatch Determine if service action or tracking event
B155B086 A device did not respond to an I2C or smartchip request but using other logic we found in firmware that the FRU is actually present on the system Determine if service action or tracking event
B155B087 We had an error in trying to detect if this FRU was actually present or not on the system Determine if service action or tracking event
B155B08F We failed trying to configure bits for 9555/9554 controllers Determine if service action or tracking event
B155B090 We failed trying to create smart chip block Determine if service action or tracking event
B155B091 Error occurred while locking/unlocking DASD device Determine if service action or tracking event
B155B096 Unsupported bit definition found in the VPD data for record_99 Determine if service action or tracking event
B155B0AA Error reading from the device Determine if service action or tracking event
B157E500 Bad hardware Determine if service action or tracking event
B157F131 Last bits of chip command status are not 0x01 Determine if service action or tracking event
B157F20D The JTAG chain pointer was initialized to NULL and maybe do to an invalid input Determine if service action or tracking event
B157F244 A chip has been found to be missing Determine if service action or tracking event
B158E500 Bad hardware Determine if service action or tracking event
B158F7A3 Clock failure during test Determine if service action or tracking event
B158F7A4 Processor gets clock errors with each clock input Determine if service action or tracking event
B158F7A5 The memory controller gets clock errors with both clock inputs Determine if service action or tracking event
B159A070 Indicates that the Panel is being deactivated Determine if service action or tracking event
B15A5000 There is a hardware problem with the RTC Determine if service action or tracking event
B15A5002 One-time log stating that the FSP time is invalid and needs to be reset Determine if service action or tracking event
B15A5004 The FSP battery needs replacing Determine if service action or tracking event
B1701001 DMA driver has encountered an error Determine if service action or tracking event
B1701002 DMA driver has encountered an error Determine if service action or tracking event
B1701003 DMA driver has encountered an error due to hardware checkstop during a read operation in the IPL mode Determine if service action or tracking event
B1701004 DMA driver has encountered an error due to a target abort in the IPL mode during a read operation Determine if service action or tracking event
B1701005 DMA driver has encountered an unknown error in TCE mode during read operation Determine if service action or tracking event
B1701006 DMA driver has encountered an error due to hardware checkstop during a write operation in the IPL mode Determine if service action or tracking event
B1701007 DMA driver has encountered an error due to a target abort in the IPL mode during a write operation Determine if service action or tracking event
B1701008 DMA driver has encountered an unknown error in IPL mode during write operation Determine if service action or tracking event
B1701009 DMA driver has encountered an error due to hardware checkstop during a read operation in the TCE mode Determine if service action or tracking event
B170100A DMA driver has encountered an error due to a target abort in the TCE mode during a read operation Determine if service action or tracking event
B170100D DMA driver has encountered an error due to a target abort in the TCE mode during a write operation Determine if service action or tracking event
B170100F DMA driver returned a zero Determine if service action or tracking event
B1701010 User given data length doesn't match with the amount of data being DMA’d Determine if service action or tracking event
B1701012 User given data length doesn't match with the amount of data being DMA’d Determine if service action or tracking event
B1701018 Failed to verify host PCI Determine if service action or tracking event
B1701019 Failed to enable host PCI Determine if service action or tracking event
B1701029 Data which is written via DMA does not match with the data being read from the same address using JTAG Determine if service action or tracking event
B170102A Data which is written via DMA does not match with the data being read from the same address using DMA Determine if service action or tracking event
B170102B DMA verification failed while writing random data at the host address Determine if service action or tracking event
B1701040 Error occurred in code Determine if service action or tracking event
B170901F SPIRA does not have sufficient space for the data structure Determine if service action or tracking event
B1709029 Data read from mainstore is not the same as what was written to mainstore Determine if service action or tracking event
B170E500 Bad hardware Determine if service action or tracking event
B170F668 Maintenance SUE during memory preserving or exit/error state IPL Determine if service action or tracking event
B1748812 A Fatal system attention was received so the Service Routine failed to complete Determine if service action or tracking event
B175E019 Communication with the IPAP failed Determine if service action or tracking event
B175E01A This entry is to record a successful communication with RETAIN, contains the PMH number and the response from retain regarding the call packet. Determine if service action or tracking event
B175E01B We sent the 20 record to RETAIN, for some reason they did not ask for the first call data packet, we log this error and move on, since we did not send the error data to RETAIN it's not a success. Determine if service action or tracking event
B175E01C We sent the logon record and did not get a successful response Determine if service action or tracking event
B175E01D We sent the user record and did not get a successful response the machine may not be entitled Determine if service action or tracking event
B175E500 Bad hardware Determine if service action or tracking event
B1764020 Invalid data was found in the registry entry Determine if service action or tracking event
B1764024 The Hyperboot capability value is being changed from ENABLED to CAPABLE due to the value of Service Processor IPL type. Determine if service action or tracking event
B176501F Invalid data was found in the rtim registry entry Determine if service action or tracking event
B1765020 The system time was changed Determine if service action or tracking event
B1765023 The Timed Power On was disabled due to invalid system time Determine if service action or tracking event
B1765024 The rtiminit daemon received an invalid command in a socket message Determine if service action or tracking event
B176E500 Bad hardware Determine if service action or tracking event
B176F687 Bit 2 set in Interrupt Register on Winnipeg Determine if service action or tracking event
B176F7BC The user specified LMB size is not valid for this system's memory size, so the system will use the default LMB size for this configuration Determine if service action or tracking event
B17BE434 PHYP failed to send its heartbeat message within the stipulated time Determine if service action or tracking event
B17CE433 Hardware Management Console failed to send its heartbeat message within the stipulated time Determine if service action or tracking event
B1806003 Unable to complete fork operation Determine if service action or tracking event
B1806006 Failed to allocate memory for object Determine if service action or tracking event
B1806007 Error receiving message Determine if service action or tracking event
B1806009 Invalid state set for State Manager Determine if service action or tracking event
B180600A Invalid state set for State Manager Determine if service action or tracking event
B180600C Error in the size of the registry value Determine if service action or tracking event
B180600D Bad size of registry value Determine if service action or tracking event
B180600E Could not read the registry Determine if service action or tracking event
B180600F Failed to write to the registry Determine if service action or tracking event
B1806010 Invalid current and next state Determine if service action or tracking event
B1806011 Invalid file state Determine if service action or tracking event
B1806013 Invalid state set for State Manager Determine if service action or tracking event
B180601A Failed to reset the file open Determine if service action or tracking event
B180601C Failed to decode reset values Determine if service action or tracking event
B180601D Failed to allocate memory for object Determine if service action or tracking event
B1806021 Failed to write to message in queue Determine if service action or tracking event
B1806022 Failed to read from message in queue Determine if service action or tracking event
B1806023 Failed to look up file from required type Determine if service action or tracking event
B1806025 Failed to reboot Determine if service action or tracking event
B1806026 Failed to open map file Determine if service action or tracking event
B180602B Failed to read Manufacturing flag for reset/reload Determine if service action or tracking event
B1806030 Invalid character Determine if service action or tracking event
B1806031 Error receiving log from client library Determine if service action or tracking event
B1806033 Failed to synchronize with the State Manager server Determine if service action or tracking event
B1806035 Failed IPL type Determine if service action or tracking event
B1806036 Validation of PCS failed Determine if service action or tracking event
B1806037 Tool reset occurred Determine if service action or tracking event
B180E500 Bad hardware Determine if service action or tracking event
B1811013 Failed to open DMA driver Determine if service action or tracking event
B1811016 Could not retrieve debug configuration information from the DMA driver Determine if service action or tracking event
B1811017 Could not retrieve debug configuration information from the DMA driver Determine if service action or tracking event
B181101A User asking to do a zero length DMA Determine if service action or tracking event
B181101B User asking to do a zero length DMA Determine if service action or tracking event
B181101C Invalid FSP address received from user Determine if service action or tracking event
B181101D Invalid FSP address received from user Determine if service action or tracking event
B181101E Bad tag data Determine if service action or tracking event
B181101F Bad tag data Determine if service action or tracking event
B1811020 Bad tag data Determine if service action or tracking event
B1811021 Cannot DMA when FSP state is between Instruction Start and OLC Determine if service action or tracking event
B1811022 Invalid value for bus controller Determine if service action or tracking event
B1811026 There has been a power off just before or during the DMA Determine if service action or tracking event
B1811027 Could not open file Determine if service action or tracking event
B1811028 Could not open file Determine if service action or tracking event
B181102C Client thread that was supposed to collect DMA error data timed out Determine if service action or tracking event
B181102D Event Manager constructor failed Determine if service action or tracking event
B181102F Could not query the CHIC reserve identity Determine if service action or tracking event
B1811030 DMA event listener deleted by another DMA thread Determine if service action or tracking event
B1811031 Failed to wait for thread conditional Determine if service action or tracking event
B1811032 Failed to join with thread Determine if service action or tracking event
B1811033 Client thread that was supposed to collect DMA error data encountered some error Determine if service action or tracking event
B1811035 TCE mode shouldn't have been set before PHYP lids are loaded Determine if service action or tracking event
B1811036 No useful DMA error data returned Determine if service action or tracking event
B1811037 No HOM ID for the enterprise chip found was returned Determine if service action or tracking event
B1811038 Maximum number of Service Processor resource identities returned was zero Determine if service action or tracking event
B1811039 Service Processor resource identities is zero Determine if service action or tracking event
B181103A No identity match for current FSP Determine if service action or tracking event
B181103B No corresponding DMA path was returned for the current resource identity Determine if service action or tracking event
B181103D No resource id for the enterprise chip found was returned Determine if service action or tracking event
B181103E No HOM ID for the node found was returned Determine if service action or tracking event
B181103F User gave an invalid TCE address. The upper 32 bits of the TCE token is non zero which is not a valid token. Determine if service action or tracking event
B1811040 Failed to get processor state Determine if service action or tracking event
B1811041 Current power state is undefined Determine if service action or tracking event
B1811044 Timeout waiting for CEC debug data Determine if service action or tracking event
B1811045 The MainStore address being written to is within a range which produces unpredictable results Determine if service action or tracking event
B1811101 Bad command given when trying to send on I2C Determine if service action or tracking event
B1811103 Failed to receive on slave I2C Determine if service action or tracking event
B1811104 Failed to send on I2C Determine if service action or tracking event
B1811109 Panel display line 1 data truncated Determine if service action or tracking event
B1811110 Panel display line 2 data truncated Determine if service action or tracking event
B1811112 Checksum failure Determine if service action or tracking event
B1811114 Failed to open I2C Determine if service action or tracking event
B1811115 Failed to close I2C Determine if service action or tracking event
B1811117 Button press/release sequence violated Determine if service action or tracking event
B1811118 Failed to configure I2C Determine if service action or tracking event
B1811119 Failed to receive on slave I2C Determine if service action or tracking event
B1811401 Invalid parameter passed to function Determine if service action or tracking event
B1811402 Failed to open I2C Determine if service action or tracking event
B1811403 Failed to close I2C Determine if service action or tracking event
B1811404 Failed to transmit on I2C Determine if service action or tracking event
B1811405 Failed to configure I2C Determine if service action or tracking event
B1811406 Message received from RPC was bigger than buffer Determine if service action or tracking event
B1811501 Failed to set reset Determine if service action or tracking event
B1811502 Failed chip select Determine if service action or tracking event
B1811503 Failed to set wrap enable Determine if service action or tracking event
B1811504 Failed to get present device Determine if service action or tracking event
B1811505 Failed to set GPIO lines Determine if service action or tracking event
B1811506 Failed to setup UART hardware to wrap Determine if service action or tracking event
B1811507 Failed to open UART Determine if service action or tracking event
B1811508 Failed to set timeout for UART Determine if service action or tracking event
B1811509 Failed to set automatic transmit for UART Determine if service action or tracking event
B181150a Failed to set normal transmit for UART Determine if service action or tracking event
B181150b Failed to set received for UART Determine if service action or tracking event
B181150c Failed to write UART buffer Determine if service action or tracking event
B181150d Failed to read UART buffer Determine if service action or tracking event
B181150e Wrap test data compare failed Determine if service action or tracking event
B181150f Failed to set functioning device Determine if service action or tracking event
B1811510 Failed to close UART Determine if service action or tracking event
B1811511 Failed to get present device Determine if service action or tracking event
B1811512 Failed to set reset Determine if service action or tracking event
B1811513 Failed to receive input deglitch from SPCN via UART Determine if service action or tracking event
B1811514 Failed to set present device Determine if service action or tracking event
B1811515 Failed to set device unit representation Determine if service action or tracking event
B1811516 Failed to set GPIO driver type to PUSHPULL Determine if service action or tracking event
B1811517 Failed to set GPIO pin Determine if service action or tracking event
B1811518 Failed to reset pins Determine if service action or tracking event
B1811519 Failed to reset pin polarity Determine if service action or tracking event
B181151a Failed to set baud rate for UART Determine if service action or tracking event
B181151b Failed to set parity mode for UART Determine if service action or tracking event
B181151c Failed to set check mode for UART Determine if service action or tracking event
B181151d Failed to set stop bit length for UART Determine if service action or tracking event
B181151e Failed to set end of transmit timeout for UART Determine if service action or tracking event
B181151f Failed to set end of message timeout for UART Determine if service action or tracking event
B1811520 Failed to select chip pins Determine if service action or tracking event
B1811521 Failed to get chip pins Determine if service action or tracking event
B1811522 Timeout waiting to receive message on UART Determine if service action or tracking event
B1811523 Timeout waiting to receive message on UART Determine if service action or tracking event
B1811524 Failed to write to UART Determine if service action or tracking event
B1811525 Failed to select pins for function Determine if service action or tracking event
B1811526 Failed to select pins for function Determine if service action or tracking event
B1811527 Failed to select pins for function Determine if service action or tracking event
B1811528 Failed to get address line setting Determine if service action or tracking event
B1811529 Failed to get address pins polarity Determine if service action or tracking event
B181152a Failed to set address GPIO value Determine if service action or tracking event
B181152b Failed to set address GPIO driver type to PUSHPULL Determine if service action or tracking event
B181152c Registry Read call returned an error Determine if service action or tracking event
B181152d Failed to set function line Determine if service action or tracking event
B181152e Failed to close UART Determine if service action or tracking event
B181152f Failed to open UART Determine if service action or tracking event
B1811531 A non-present device was accessed Determine if service action or tracking event
B1811532 Failed to prep for read/write Determine if service action or tracking event
B1811533 Failed to get sequence retry count Determine if service action or tracking event
B1811534 Failed to set next send/receive flag Determine if service action or tracking event
B1811535 Failed to get next send/receive flag Determine if service action or tracking event
B1811536 Requested transaction size too large Determine if service action or tracking event
B1811537 Failed to set next send sequence bit Determine if service action or tracking event
B1811538 Failed to set next receive sequence bit Determine if service action or tracking event
B1811539 Received message from smart chip is invalid Determine if service action or tracking event
B181153a Failed to set next receive sequence bit Determine if service action or tracking event
B181153b Failed to set next send sequence bit Determine if service action or tracking event
B181153c Failed to set next send receive flag Determine if service action or tracking event
B181153d Failed to set next send sequence bit Determine if service action or tracking event
B181153e Failed to set next receive sequence bit Determine if service action or tracking event
B181153f Failed to set next send receive flag Determine if service action or tracking event
B1811541 Failed to set next send sequence bit Determine if service action or tracking event
B1811542 Failed to set next receive sequence bit Determine if service action or tracking event
B1811543 Failed to execute wrap reset test Determine if service action or tracking event
B1811544 Failed to execute transaction Determine if service action or tracking event
B1811545 Failed to reset VPD devices Determine if service action or tracking event
B1811546 Failed reset test Determine if service action or tracking event
B1811547 Failed to zero all device sequence bits Determine if service action or tracking event
B1811548 Failed to set valid configuration flag Determine if service action or tracking event
B1811549 Failed to get next receive sequence bit Determine if service action or tracking event
B181154a Failed to get next send sequence bit Determine if service action or tracking event
B181154b Failed to reset devices Determine if service action or tracking event
B181154c Failed to get valid configuration flag Determine if service action or tracking event
B181154d Failed reading the configuration id from GPIO Determine if service action or tracking event
B181154e The configuration id read from the GPIO pins on this system is invalid Determine if service action or tracking event
B181154f Configuration registry read back test failed Determine if service action or tracking event
B1811550 Failed to get reserve for sced Determine if service action or tracking event
B1811551 Failed to reset Determine if service action or tracking event
B1811552 Failed to release reserve for sced Determine if service action or tracking event
B1811553 Non-zero response code returned Determine if service action or tracking event
B1811554 The number of bytes read doesn’t match the bytes requested Determine if service action or tracking event
B1811555 Failed to send command Determine if service action or tracking event
B1811556 No sender id detected in call Determine if service action or tracking event
B1811557 Failed to get mux information from VPD Determine if service action or tracking event
B1811558 Failed any bytes in or out Determine if service action or tracking event
B1811559 Failed zero bytes in or out Determine if service action or tracking event
B181155a Registry write call returned an error Determine if service action or tracking event
B181155b Registry Read call returned an error Determine if service action or tracking event
B181155c Failed to get file name for GPIO configuration parser Determine if service action or tracking event
B181155d Failed to open file Determine if service action or tracking event
B181155e Failed to read number of entries from file Determine if service action or tracking event
B181155f Failed to read pin information from file Determine if service action or tracking event
B1811560 Invalid pointer Determine if service action or tracking event
B1811561 Received a undefined command type Determine if service action or tracking event
B1811562 Received a undefined command type Determine if service action or tracking event
B1811563 GPIO pin file not loaded yet Determine if service action or tracking event
B1811564 Bad value in pin group Determine if service action or tracking event
B1811565 Registry Read call returned an error Determine if service action or tracking event
B1811566 Failed to set device present flag to false Determine if service action or tracking event
B1811567 GPIO pin file not loaded yet Determine if service action or tracking event
B1811568 Bad value in pin group Determine if service action or tracking event
B181156a Error from sced internals Determine if service action or tracking event
B181156b Error from network server address Determine if service action or tracking event
B181156e Failed message control Determine if service action or tracking event
B181156f Failed to get message Determine if service action or tracking event
B1811570 Failed to create thread for sced Determine if service action or tracking event
B1811571 Failed to create thread for event handling Determine if service action or tracking event
B1811572 Failed to get path from registry for synchronization Determine if service action or tracking event
B1811573 Failed to bind socket for network server Determine if service action or tracking event
B1811574 Failed to listen on socket for network server Determine if service action or tracking event
B1811575 Failed to synchronize with server for sced Determine if service action or tracking event
B1811576 Invalid pointer returned from synchronization Determine if service action or tracking event
B1811577 Failed to connect to network server Determine if service action or tracking event
B1811578 Failed to receive from network server Determine if service action or tracking event
B1811579 Failed to send message Determine if service action or tracking event
B181157a Reached maximum number of failures for attempts with network server Determine if service action or tracking event
B181157b Message Processing Request has an unknown operation Determine if service action or tracking event
B181157c Failed to get path from registry Determine if service action or tracking event
B181157d Invalid current packet number Determine if service action or tracking event
B181157e Failed to reset type in and zero out Determine if service action or tracking event
B181157f Failed to zero single device sequence bits Determine if service action or tracking event
B1811580 Failed to reset single device Determine if service action or tracking event
B1811581 Failed to reset single VPD device Determine if service action or tracking event
B1811590 Failed to get reserve for sced Determine if service action or tracking event
B1811591 Maximum number of pin failures has been reached Determine if service action or tracking event
B1811596 Failed to get reserve for sced Determine if service action or tracking event
B1811597 Failed to get reserve for sced Determine if service action or tracking event
B181159A Parsing of return packet failed Determine if service action or tracking event
B181159D Received an unexpected signal Determine if service action or tracking event
B1812000 Unexpected signal received Determine if service action or tracking event
B1812001 Failed to open file Determine if service action or tracking event
B1812002 Failed to initialize trace Determine if service action or tracking event
B1812003 No name for thread in trace Determine if service action or tracking event
B1812004 Error reading from registry Determine if service action or tracking event
B1812005 Error setting up iterator for SRCs Determine if service action or tracking event
B1812006 Failed to get SRC from SRC iterator Determine if service action or tracking event
B1812007 Invalid pointer Determine if service action or tracking event
B1812008 Failed to lock the mutex Determine if service action or tracking event
B1812009 Failed to unlock the mutex Determine if service action or tracking event
B181200a Error from event manager constructor Determine if service action or tracking event
B181200b Error from event management monitor Determine if service action or tracking event
B181200c Error from event management signal Determine if service action or tracking event
B1812017 Could not initialize queue mutex Determine if service action or tracking event
B1812018 The condition variables could not be initialized Determine if service action or tracking event
B1812019 The condition variables could not be destroyed Determine if service action or tracking event
B181201a Could not destroy queue mutex Determine if service action or tracking event
B181201b A power fault has been detected Determine if service action or tracking event
B181201c Failed to wait on thread conditional Determine if service action or tracking event
B181201d Failed to write to registry Determine if service action or tracking event
B181201e Failed to signal on thread conditional Determine if service action or tracking event
B181201f Failed to create notify thread Determine if service action or tracking event
B1812020 Failed to cancel the threads Determine if service action or tracking event
B1812021 Failed to set cancel state of thread Determine if service action or tracking event
B1812023 Failed to join to thread created Determine if service action or tracking event
B1812024 Failed to communicate with SPCN Determine if service action or tracking event
B1812025 Failed to stop communication with SPCN Determine if service action or tracking event
B1812026 Thread is being canceled while in the middle of sending a command to SPCN Determine if service action or tracking event
B1812027 Server has routed an acknowledgment message to the command queue Determine if service action or tracking event
B1812028 The command was rejected by SPCN Determine if service action or tracking event
B1812029 Could not send a message through the interface to SPCN Determine if service action or tracking event
B181202a Could not read a message from the interface to SPCN Determine if service action or tracking event
B181202b Failed to create network server object Determine if service action or tracking event
B181202c Failed to listen to socket for network server Determine if service action or tracking event
B181202d Failed process synchronization with client Determine if service action or tracking event
B181202e Failed to close network server Determine if service action or tracking event
B181202f Failed to connect to network server Determine if service action or tracking event
B1812030 Failed to receive from network server Determine if service action or tracking event
B1812031 Failed to bind to socket for network server Determine if service action or tracking event
B1812032 Incorrect data received Determine if service action or tracking event
B1812033 The delayed response has been aborted and the caller is prohibited from attempting to update the socket value Determine if service action or tracking event
B1812034 Failed to get configuration ID from SPCN Determine if service action or tracking event
B1812035 Failed to set configuration ID Determine if service action or tracking event
B1812036 Failed to deattach thread Determine if service action or tracking event
B1812037 Error getting subfunction ranges for SPCN panel function Determine if service action or tracking event
B1812038 The notification cannot be sent to state manager because the fsp is not in a particular state Determine if service action or tracking event
B1812039 Error from state manager power off notification Determine if service action or tracking event
B181203a Error from state manager power on notification Determine if service action or tracking event
B181203b The condition was not satisfied before specified interval Determine if service action or tracking event
B181203c Failed to wait for thread conditional Determine if service action or tracking event
B181203d Server queue is full Determine if service action or tracking event
B181203e Server queue is empty Determine if service action or tracking event
B181203f Already started server Determine if service action or tracking event
B1812040 Unrecognized command Determine if service action or tracking event
B1812041 Failed to get path from registry Determine if service action or tracking event
B1812042 Failed direct command to SPCN Determine if service action or tracking event
B1812043 Failed to get maximum number of RIDs from SVPD Determine if service action or tracking event
B1812044 Unexpected SVPD data Determine if service action or tracking event
B1812045 Failed to get RIDs from SVPD Determine if service action or tracking event
B1812046 Failed to figure out which FSP running on Determine if service action or tracking event
B1812047 Timed out waiting for an acknowledgment Determine if service action or tracking event
B1812048 Failed to set UPS status for SPCN Determine if service action or tracking event
B1812049 Error from SPCN when trying to power off I/O Determine if service action or tracking event
B181204A Error from SPCN command line handler Determine if service action or tracking event
B1812100 Failed to initialize Determine if service action or tracking event
B1812102 Failure creating thread Determine if service action or tracking event
B1812103 Pipe system call failed Determine if service action or tracking event
B1812104 System call failed Determine if service action or tracking event
B1812105 Select system call failed Determine if service action or tracking event
B1812106 Invalid parameter passed to function Determine if service action or tracking event
B1812107 Could not create message queue Determine if service action or tracking event
B1812108 Received invalid command from RPC device Determine if service action or tracking event
B1812109 Invalid function ID from message Determine if service action or tracking event
B181210A Timeout receive though no timeout was given Determine if service action or tracking event
B181210B Expected file descriptor not set after select call Determine if service action or tracking event
B181210C Failed to do an I2C slave address change on a redundant FSP failover Determine if service action or tracking event
B181210D Could not insert initial events into queue Determine if service action or tracking event
B181210E Error removing message from queue Determine if service action or tracking event
B181210F Failed to get power state Determine if service action or tracking event
B1812110 Failed IPL lock function Determine if service action or tracking event
B1812111 Failed to close network server Determine if service action or tracking event
B1812112 Error from Event Manager Determine if service action or tracking event
B1812113 Could not create token queue Determine if service action or tracking event
B1812114 Could not insert tokens into token queue Determine if service action or tracking event
B1812115 Over total thread threshold Determine if service action or tracking event
B1812201 Failed to open and lock the IPL Lock data file Determine if service action or tracking event
B1812202 Failed to unlock and/or close the IPL Lock data file Determine if service action or tracking event
B1812203 Failed to initialize the header of the IPL Lock data file Determine if service action or tracking event
B1812204 Failed to read from registry Determine if service action or tracking event
B1812205 Failed to position the cursor in the file or read the header from the file Determine if service action or tracking event
B1812206 Failed to position the cursor in the file or write the lock information to the file Determine if service action or tracking event
B1812207 Failed to read lock information Determine if service action or tracking event
B1812208 Failed to write the new lock information to the IPL Lock data file Determine if service action or tracking event
B1812209 Failed to read the header in the IPL Lock data file Determine if service action or tracking event
B181220A Failed to update new header in IPL Lock data file Determine if service action or tracking event
B181220B Invalid parameter passed into function Determine if service action or tracking event
B181220C Invalid power state for IPL requested Determine if service action or tracking event
B181220D Failed to get current power state of system Determine if service action or tracking event
B181220E Failed to open and lock the IPL Lock data file Determine if service action or tracking event
B181220F Failed to close and/or unlock the IPL Lock data file Determine if service action or tracking event
B1812210 No locks exist or the requested lock exceeds the total number of locks that exist Determine if service action or tracking event
B1812211 A lock by the requesting component still exists and is active Determine if service action or tracking event
B1812212 An error occurred trying to find the lock for the component Determine if service action or tracking event
B1812213 Failure to allocate memory for timer thread structure Determine if service action or tracking event
B1812214 Failure to create timer thread for lock Determine if service action or tracking event
B1812215 Failure to remove requested lock Determine if service action or tracking event
B1812216 Component requesting refresh does not have a lock in the IPL Lock data file Determine if service action or tracking event
B1812218 IPL requested is blocked due to an IPL lock Determine if service action or tracking event
B1812219 Value passed in to set Power IPL in Progress to was out of range Determine if service action or tracking event
B181221A Emergency IPL was received and locks were bypassed Determine if service action or tracking event
B181221B IPL was rejected by State Manager or the acknowledge was not accepted Determine if service action or tracking event
B181221C A Power IPL has already been requested and queued Determine if service action or tracking event
B181221D Failed to send Power On event to Panel for requested IPL Determine if service action or tracking event
B181221E Failed to send Power Off event to Panel Determine if service action or tracking event
B181221F Failed fork system call Determine if service action or tracking event
B1812220 Failed to start IPL Power process due to not being able to replace current executable with IPL Power process Determine if service action or tracking event
B1812221 Invalid argument was passed into the timer thread Determine if service action or tracking event
B1812222 Invalid signal received Determine if service action or tracking event
B1812223 Failure to detach timer thread so memory resources will not be freed upon termination of the timer thread Determine if service action or tracking event
B1812224 A Power IPL is in progress Determine if service action or tracking event
B1812225 Failed to get Power IPL in Progress indicator Determine if service action or tracking event
B1812226 Failed to write to Power IPL in Progress registry variable Determine if service action or tracking event
B1812227 Failed to indicate that a Power IPL will be in progress Determine if service action or tracking event
B1812228 Failed to get current and next state Determine if service action or tracking event
B1812229 Failed to read current FSP Role from registry Determine if service action or tracking event
B181222A An invalid pointer was passed into the function Determine if service action or tracking event
B181222B Failed to determine the size of the IPL Lock data file Determine if service action or tracking event
B181222C An error occurred trying to get current ticks Determine if service action or tracking event
B1812300 Unexpected signal received Determine if service action or tracking event
B1812301 Failed fork operation Determine if service action or tracking event
B1812304 Error while querying for CEC termination Determine if service action or tracking event
B1812305 Synchronization with State Manager failed Determine if service action or tracking event
B1812306 Failed to read maximum size of error Determine if service action or tracking event
B1812307 Failed to write to registry Determine if service action or tracking event
B1812308 Error creating termination iterator Determine if service action or tracking event
B1812309 Failed to read termination SRC Determine if service action or tracking event
B181230B Failed to read path from registry Determine if service action or tracking event
B181230C Error from event monitor Determine if service action or tracking event
B181230D Server not ready or daemon is not running Determine if service action or tracking event
B181230E Failed to synchronize with client Determine if service action or tracking event
B181230F Error returned from IPL lock function Determine if service action or tracking event
B1812311 Error from event manager constructor Determine if service action or tracking event
B1812401 Failed to write WOL Policy to registry Determine if service action or tracking event
B1812402 Failed to read WOL Policy from registry Determine if service action or tracking event
B1812403 Failed to HIGH-LOW-HIGH the Wake on LAN reset line Determine if service action or tracking event
B1812404 Failure to setup Wake on LAN reset line Determine if service action or tracking event
B1812405 Failed to get current power state, so we were not able to activate the Wake on LAN hardware Determine if service action or tracking event
B1812406 Invalid signal received Determine if service action or tracking event
B1812407 Failed to activate Wake on LAN hardware Determine if service action or tracking event
B1812408 Failed to IPL the system via Wake on LAN Determine if service action or tracking event
B1812409 Failed to get Wake on LAN Policy Determine if service action or tracking event
B181240A The value for the Wake on LAN Policy is out of range for what is acceptable Determine if service action or tracking event
B181240B Failed fork system call Determine if service action or tracking event
B181240C An error was returned as we tried to wait for the Wake on LAN interrupt line Determine if service action or tracking event
B181240D An error occurred processing the Wake on LAN interrupt Determine if service action or tracking event
B181240E Failed to get root path from the registry. Determine if service action or tracking event
B181240F A daemon is already up and running Determine if service action or tracking event
B1812410 Failed to create the daemon synchronization file Determine if service action or tracking event
B1812411 Due to the type of machine, the Wake on LAN functionality is not supported Determine if service action or tracking event
B1812412 Failed to read current state data from registry Determine if service action or tracking event
B1812413 Failed to read FSP Role from registry Determine if service action or tracking event
B1812414 Failed to read machine model type from registry Determine if service action or tracking event
B1812415 Failed to read operational mode from registry Determine if service action or tracking event
B1813001 Someone is already updating code Determine if service action or tracking event
B1813002 Registry read fails Determine if service action or tracking event
B1813003 Registry write fails Determine if service action or tracking event
B1813006 Lid Entry is not found. The specified Lid number is not in the specified Masterlid file Determine if service action or tracking event
B1813007 Invalid Lid number Determine if service action or tracking event
B1813008 Lid is not valid Determine if service action or tracking event
B1813009 Request to update the wrong lid Determine if service action or tracking event
B181300A Requestor did not start the update Determine if service action or tracking event
B181300C Type of code update is already set Determine if service action or tracking event
B181300D Invalid flash side Determine if service action or tracking event
B181300E In correct flash side Determine if service action or tracking event
B181300F Header has invalid magic number Determine if service action or tracking event
B1813010 System command fails to remove a file Determine if service action or tracking event
B1813011 File open error Determine if service action or tracking event
B1813012 Lid does not exist Determine if service action or tracking event
B1813013 Someone is currently updating the specified lid Determine if service action or tracking event
B1813014 Request IPL lock or unlock fails Determine if service action or tracking event
B1813015 Lid class is invalid Determine if service action or tracking event
B1813016 Specified buffer is too small for the requesting data Determine if service action or tracking event
B181301F Updating on the running side is not allowed Determine if service action or tracking event
B1813020 Update good flash side, when other side is invalid Determine if service action or tracking event
B1813022 CRC miscompare Determine if service action or tracking event
B1813025 Invalid data size is detected Determine if service action or tracking event
B1813028 IPL lock refresh fails Determine if service action or tracking event
B1813029 Invalid component id Determine if service action or tracking event
B181302A Lid is currently being modified by someone Determine if service action or tracking event
B1813030 Invalid code type Determine if service action or tracking event
B1813031 Invalid Marker Lid version Determine if service action or tracking event
B1813034 Invalid operation state Determine if service action or tracking event
B1813035 Offset is exceeding the file size Determine if service action or tracking event
B1813036 Someone requests code update termination Determine if service action or tracking event
B1813038 Unable to create event Determine if service action or tracking event
B1813039 Unable to create thread to monitor the power lock timeout Determine if service action or tracking event
B181303a Lid does not belong to FSP Determine if service action or tracking event
B181303b The power log flag is not set Determine if service action or tracking event
B181303d Invalid data Determine if service action or tracking event
B181303e Function call fails Determine if service action or tracking event
B181303f Reading offset to partition table failed Determine if service action or tracking event
B1813040 Write the partition name to a specific partition table entry failed Determine if service action or tracking event
B1813041 Seek file from the end of file failed Determine if service action or tracking event
B1813042 The status of the MTD device failed Determine if service action or tracking event
B1813043 Invalid Genus size Determine if service action or tracking event
B1813044 Incorrect file for update Determine if service action or tracking event
B1813045 Unable to find keyword that indicate bank id Determine if service action or tracking event
B1813047 The system has redundant FSP Determine if service action or tracking event
B1813048 The specified arguments for major/minor number are out of range Determine if service action or tracking event
B1813049 The filename that is passed in does not start with a '/' Determine if service action or tracking event
B181304a The status of the MTD device failed Determine if service action or tracking event
B181304f Invalid operation Determine if service action or tracking event
B1813050 Unknown signal Determine if service action or tracking event
B1813501 Error in call to other component interface Determine if service action or tracking event
B1813503 Error received from sibling FSP Determine if service action or tracking event
B1813509 Error setting network parameters for various ethernet interface Determine if service action or tracking event
B181350B Error creating network client object Determine if service action or tracking event
B181350C We detected a sibling but the communication broke down in between Determine if service action or tracking event
B181350D Error configuring various ethernet interface Determine if service action or tracking event
B181350F Error in call to other component interface Determine if service action or tracking event
B1813511 Error sending data to sibling Determine if service action or tracking event
B1813515 Error obtaining mux information Determine if service action or tracking event
B1813516 Error in interface call to other component Determine if service action or tracking event
B1813519 Bad command received from sibling FSP Determine if service action or tracking event
B181351A Communication to sibling failed Determine if service action or tracking event
B181351B Error reading FSP State Determine if service action or tracking event
B181351C Error waiting for an event Determine if service action or tracking event
B181351E Error getting time of day Determine if service action or tracking event
B181351F Error setting time of day Determine if service action or tracking event
B1813520 Error indicating that sibling FSP was already garded Determine if service action or tracking event
B1813521 Error creating a event object Determine if service action or tracking event
B1813523 Error creating network client object Determine if service action or tracking event
B1813524 We detected a sibling but the communication broke down in between Determine if service action or tracking event
B1813525 We detected a sibling but the communication broke down in between Determine if service action or tracking event
B1813527 Failed to read from registry Determine if service action or tracking event
B1813528 Failed to read size from registry Determine if service action or tracking event
B1813529 We detected a sibling but the communication broke down in between Determine if service action or tracking event
B181352A Error reading registry entry size Determine if service action or tracking event
B181352B Error writing pass phrase to registry entry Determine if service action or tracking event
B181352C Error reading sibling ethernet port 0 registry entry Determine if service action or tracking event
B181352D Error writing to sibling ethernet port 0 registry entry Determine if service action or tracking event
B181352E Error reading sibling ethernet port 1 registry entry. Determine if service action or tracking event
B181352F Error writing to sibling ethernet port 1 registry entry. Determine if service action or tracking event
B1813531 Error writing MTMS to file Determine if service action or tracking event
B1813532 Error reading registry entry size Determine if service action or tracking event
B1813533 Error reading registry entry Determine if service action or tracking event
B1813534 Error reading/writing from file Determine if service action or tracking event
B1813535 Error reading/writing from file Determine if service action or tracking event
B1813536 Error reading/writing from file Determine if service action or tracking event
B1813537 Error reading/writing from file Determine if service action or tracking event
B1813538 Error reading/writing from file Determine if service action or tracking event
B1813539 Error reading/writing from file Determine if service action or tracking event
B181353A Error reading/writing from file Determine if service action or tracking event
B181353B Error reading/writing from file Determine if service action or tracking event
B181353C Error in network operation Determine if service action or tracking event
B181353D Error in network operation Determine if service action or tracking event
B181353E Error in network operation Determine if service action or tracking event
B181353F Error in network operation Determine if service action or tracking event
B1813540 Error in network operation Determine if service action or tracking event
B1813541 Error in network operation Determine if service action or tracking event
B1813542 Error in network operation Determine if service action or tracking event
B1813543 Error in network operation Determine if service action or tracking event
B1813544 Error in network operation Determine if service action or tracking event
B1813545 Error in network operation Determine if service action or tracking event
B1813546 Error in network operation Determine if service action or tracking event
B1813547 Error in network operation Determine if service action or tracking event
B181354A Error in network operation Determine if service action or tracking event
B181354B Error in call to other component interface Determine if service action or tracking event
B181354C Error in network operation Determine if service action or tracking event
B181354D Error in call to other component interface Determine if service action or tracking event
B1813550 Error in network operation Determine if service action or tracking event
B1813551 Error in call to other component interface Determine if service action or tracking event
B1813552 Error in network operation Determine if service action or tracking event
B1813553 Error in call to other component interface Determine if service action or tracking event
B1813554 Error in network operation Determine if service action or tracking event
B1813555 Error in call to other component interface Determine if service action or tracking event
B1813556 Error in network operation Determine if service action or tracking event
B1813557 Error in network operation Determine if service action or tracking event
B1813558 Error in reading FSP Role registry Determine if service action or tracking event
B1813559 Error in call to other component interface Determine if service action or tracking event
B181355C Error in call to other component interface Determine if service action or tracking event
B181355D Error in call to other component interface Determine if service action or tracking event
B181355E Error in call to other component interface Determine if service action or tracking event
B181355F Error in call to other component interface Determine if service action or tracking event
B1813560 Error in call to other component interface Determine if service action or tracking event
B1813561 Error in call to other component interface Determine if service action or tracking event
B1813562 Error in network operation Determine if service action or tracking event
B1813563 Error in call to other component interface Determine if service action or tracking event
B1813564 Error in call to other component interface Determine if service action or tracking event
B1813569 Error in network operation Determine if service action or tracking event
B181356A Error writing MTMS to file Determine if service action or tracking event
B181356F Error reading/writing from file Determine if service action or tracking event
B1813570 Error reading/writing from file Determine if service action or tracking event
B1813579 Error setting network parameters for various ethernet interface Determine if service action or tracking event
B181357A Error in interface call to other component Determine if service action or tracking event
B181357B Error trying to setup initial communication between FSP's Determine if service action or tracking event
B181357C Error in call to other component interface Determine if service action or tracking event
B181357D Error in call to other component interface Determine if service action or tracking event
B181357E Error in interface call to other component Determine if service action or tracking event
B181357F Error starting Surveillance Determine if service action or tracking event
B1813580 Error in call to other component interface Determine if service action or tracking event
B1813581 Error in network operation Determine if service action or tracking event
B1813582 Error in network operation Determine if service action or tracking event
B1813583 Error in interface call to other component Determine if service action or tracking event
B1813584 Error sending data to sibling Determine if service action or tracking event
B1813585 Error sending data to sibling Determine if service action or tracking event
B1813586 Error sending data to sibling Determine if service action or tracking event
B1813587 Error sending data to sibling Determine if service action or tracking event
B1813588 Error sending data to sibling Determine if service action or tracking event
B1813589 Error sending data to sibling Determine if service action or tracking event
B181358A Error in call to other component interface Determine if service action or tracking event
B181358B Error in call to other component interface Determine if service action or tracking event
B181358C Error in interface call to other component Determine if service action or tracking event
B181358D Error while making open call to I2C adal Determine if service action or tracking event
B181358F Error while making open call to I2C adal Determine if service action or tracking event
B1813591 Error while making open call to I2C adal Determine if service action or tracking event
B1813592 Sibling FSP is expected but not present Determine if service action or tracking event
B1813593 Error in call to other component interface Determine if service action or tracking event
B1813594 Error in call to other component interface Determine if service action or tracking event
B1813595 Discovery abort was requested Determine if service action or tracking event
B1813596 Error in call to other component interface Determine if service action or tracking event
B1813597 Error in putting message in message queue Determine if service action or tracking event
B181359A Error while making open call to I2C adal Determine if service action or tracking event
B181359B Error while making open call to I2C adal Determine if service action or tracking event
B181359E Error setting up passwords Determine if service action or tracking event
B181359F Error closing client socket Determine if service action or tracking event
B18135A0 Error closing server socket Determine if service action or tracking event
B18135A1 Invalid request to Discovery thread Determine if service action or tracking event
B18135A2 Eth0 IP address on FSP-B was set to default Determine if service action or tracking event
B18135A3 Eth1 IP address on FSP-B was set to default Determine if service action or tracking event
B18135A4 Error while making open call to I2C adal Determine if service action or tracking event
B18135A5 Exceeded maximum number of retries for communication errors between FSP's in various states Determine if service action or tracking event
B18135A6 Error in interface call to other component Determine if service action or tracking event
B18135A7 Error in interface call to other component Determine if service action or tracking event
B18135A8 Error in interface call to other component Determine if service action or tracking event
B18135A9 Both FSPs were reset Determine if service action or tracking event
B18135AA Both FSPs were reset Determine if service action or tracking event
B18135AB Both FSPs were reset Determine if service action or tracking event
B18135AC Error sending data to sibling Determine if service action or tracking event
B18135AD Error reading registry Determine if service action or tracking event
B18135AE Error exchanging data with sibling Determine if service action or tracking event
B18135AF Error receiving data from sibling Determine if service action or tracking event
B18135B0 Error writing registry Determine if service action or tracking event
B18135B1 Error receiving data from sibling Determine if service action or tracking event
B18135B2 Error exchanging data to/from sibling Determine if service action or tracking event
B18135B3 Error in data received from sibling Determine if service action or tracking event
B18135B4 Error receiving data from sibling Determine if service action or tracking event
B18135B5 Error in call to other component interface Determine if service action or tracking event
B18135B6 Error in call to other component interface Determine if service action or tracking event
B18135B7 Error in call to other component interface Determine if service action or tracking event
B18135B8 Error receiving data from sibling Determine if service action or tracking event
B18135B9 Error receiving data from sibling Determine if service action or tracking event
B18135BA Error sending data to sibling Determine if service action or tracking event
B18135BB Error writing registry Determine if service action or tracking event
B18135BC Error receiving data from sibling Determine if service action or tracking event
B18135BD Error sending data to sibling Determine if service action or tracking event
B18135BE Error receiving data from sibling Determine if service action or tracking event
B18135BF Error receiving data from sibling Determine if service action or tracking event
B18135C0 Error receiving data from sibling Determine if service action or tracking event
B18135C1 Eth1 IP address on FSP-B was set to default Determine if service action or tracking event
B18135C2 Eth1 IP address on FSP-B was set to default Determine if service action or tracking event
B18135C3 Reset of both FSPs. Possible new role assigned to FSP-A Determine if service action or tracking event
B18135C4 Reset of both FSPs. Possible new role assigned to FSP-A Determine if service action or tracking event
B18135C5 Reset of both FSPs. Possible new role assigned to FSP-A Determine if service action or tracking event
B18135C8 Gard did not return back a status but indicated a failure in the output parameter of their routine Determine if service action or tracking event
B18135C9 Error in call to other component interface Determine if service action or tracking event
B18135CA Error in call to other component interface Determine if service action or tracking event
B18135CB Error in call to other component interface Determine if service action or tracking event
B18135CC Error in call to other component interface Determine if service action or tracking event
B18135CD Error in putting message in message queue Determine if service action or tracking event
B18135CE Error from network client gateway Determine if service action or tracking event
B18135CF Error from network client gateway Determine if service action or tracking event
B18135D0 Registry entry indicates that a serial communication error is to be simulated Determine if service action or tracking event
B18135D1 Error reading serial error injection registry Determine if service action or tracking event
B18135D2 Error in putting message in message queue Determine if service action or tracking event
B18135D3 Error in putting message in message queue Determine if service action or tracking event
B18135D4 Error in call to other component interface Determine if service action or tracking event
B18135D7 Error while making open call to I2C adal Determine if service action or tracking event
B18135D8 Error in interface call to other component Determine if service action or tracking event
B18135D9 Error in interface call to other component Determine if service action or tracking event
B18135DA Error in interface call to other component Determine if service action or tracking event
B18135DB Error indicating that sibling FSP was already garded Determine if service action or tracking event
B1814000 Invalid command Determine if service action or tracking event
B1814001 Missing argument Determine if service action or tracking event
B1814002 Invalid argument Determine if service action or tracking event
B1814003 Invalid data received for process message operation number Determine if service action or tracking event
B1814004 Wrong number of arguments given to command Determine if service action or tracking event
B1814005 An error occurred reserving the semaphore Determine if service action or tracking event
B1814006 Received unexpected signal Determine if service action or tracking event
B1814006 Receive unexpected signal Determine if service action or tracking event
B1814007 A side switching IPL is not allowed for the given type of CEC IPL Determine if service action or tracking event
B1814008 A side switching IPL is needed, but the code is not valid on that side Determine if service action or tracking event
B1814008 A side switch reboot could not be performed because the code is not valid on the new next side Determine if service action or tracking event
B1814016 Invalid data was received for next system operation mode Determine if service action or tracking event
B1814016 Invalid data was received for system click to accept state Determine if service action or tracking event
B1814017 Invalid data was received for next platform IPL side Determine if service action or tracking event
B1814018 Invalid data was received for next system IPL mode Determine if service action or tracking event
B1814019 Invalid data was received for next platform IPL speed Determine if service action or tracking event
B181401A Invalid data was received for next platform IPL speed override Determine if service action or tracking event
B181401B Invalid data was received for next Hypervisor IPL state Determine if service action or tracking event
B181401C Invalid data was received for next RPA partition IPL mode Determine if service action or tracking event
B181401D Invalid data was received for next CEC LMB size Determine if service action or tracking event
B1814021 The daemon could not get the lock Determine if service action or tracking event
B1814022 Failed fork system call Determine if service action or tracking event
B1814023 The daemon rebooted the FSP to Standby because the P2 registry data that controls labeling of Permanent and Temporary Flash images was replaced with P3 registry backup data. Determine if service action or tracking event
B1814025 Called interface not supported in context Determine if service action or tracking event
B1815001 Received unexpected signal Determine if service action or tracking event
B1815005 Invalid data received Determine if service action or tracking event
B1815006 An attempt was made to write to the system clock without proper user authority Determine if service action or tracking event
B1815007 The GPIO ADAL returned an error while reading the battery alert pin Determine if service action or tracking event
B1815008 A registry read error occurred Determine if service action or tracking event
B181501B An undefined operation was requested Determine if service action or tracking event
B181501C Error reading using Time of Day ADAL Determine if service action or tracking event
B181501D Error writing using Time of Day ADAL Determine if service action or tracking event
B181501E Error writing using Time of Day ADAL Determine if service action or tracking event
B1815021 The daemon could not get the lock Determine if service action or tracking event
B1815022 Failed fork system call Determine if service action or tracking event
B1815025 Failed to create thread Determine if service action or tracking event
B1815026 The elapsed time since IPL Parameters time data was built was calculated with the RTC and TOD counter. The two results are off by more than 8 seconds. Determine if service action or tracking event
B1815027 The TOD counter was checked after writing, and was off by more than 65536 ticks (0.524 sec). Determine if service action or tracking event
B1815029 Failed to create RMGR synchronization thread Determine if service action or tracking event
B1816009 Invalid state set for State Manager Determine if service action or tracking event
B1816010 Invalid current and next state Determine if service action or tracking event
B181601C Failed to decode reset values Determine if service action or tracking event
B181601E System was powered on with failover disabled, when there is a valid sibling Service Processor that could be used for failover. Determine if service action or tracking event
B1816030 Invalid character Determine if service action or tracking event
B1817000 Failure to create thread Determine if service action or tracking event
B1817003 Failed network server connection Determine if service action or tracking event
B1817004 Failed to receive message from network Determine if service action or tracking event
B1817005 Failed to close network connection Determine if service action or tracking event
B1817006 Failure to establish communications pipe Determine if service action or tracking event
B1817007 PHYP was not ready to be communicated with Determine if service action or tracking event
B1817008 Failed to write data Determine if service action or tracking event
B1817009 Failure reading data Determine if service action or tracking event
B181700A Load SRC failed Determine if service action or tracking event
B181700D Failed to read from or write to registry Determine if service action or tracking event
B1817010 Error reading data from server communications pipe Determine if service action or tracking event
B1817011 Data size mismatch Determine if service action or tracking event
B1817012 Error/Event notification throughout the system has failed for the given platform event log Determine if service action or tracking event
B1817013 Failed to scan for error/event logs Determine if service action or tracking event
B1817015 Error while attempting to change state Determine if service action or tracking event
B1817016 Corrupt input data Determine if service action or tracking event
B1817018 A log was picked up and the unique id assigned to it is zero Determine if service action or tracking event
B1817019 Error received while attempting to turn on virtual platform service indicator Determine if service action or tracking event
B181701A The section identifier read from the data does not match the section id of the current object Determine if service action or tracking event
B181701B Invalid section size detected Determine if service action or tracking event
B181701C Section version mismatch Determine if service action or tracking event
B181701D Section count mismatch Determine if service action or tracking event
B181701E Failed to send or receive on network Determine if service action or tracking event
B181701F Unhandled signal received Determine if service action or tracking event
B1817020 Invalid input or data Determine if service action or tracking event
B1817021 File system failure Determine if service action or tracking event
B1817022 FSP call home attempt has failed Determine if service action or tracking event
B1817024 Failed to initialize the history log, logging cannot continue if the physical file cannot be initialized Determine if service action or tracking event
B1817025 Request to clear error/event logs has been processed Determine if service action or tracking event
B1817026 Error/Event logging server started Determine if service action or tracking event
B1817028 Error/Event log created from system log message Determine if service action or tracking event
B1817029 Linux system call failed Determine if service action or tracking event
B181702A Error unloading virtual headers due to lack of file allocation space Determine if service action or tracking event
B181702B Timeout waiting for sibling FSP command to complete Determine if service action or tracking event
B181703E Unknown failure Determine if service action or tracking event
B1817102 Failed to setup process error recovery Determine if service action or tracking event
B1817107 Host driver or registry failure Determine if service action or tracking event
B181710B Event manager failed Determine if service action or tracking event
B181710D Event detection failed Determine if service action or tracking event
B1817112 Software failure resulted in a signal Determine if service action or tracking event
B1817113 Event loop exited Determine if service action or tracking event
B1817114 Failed to change directory Determine if service action or tracking event
B1817115 Failed to set session identity Determine if service action or tracking event
B1817200 User requested to boot from a side that is marked invalid FSPSP02
B1817201 FSP had a kernel panic during last boot FSPSP02
B1817202 Both FSP code banks are marked invalid FSPSP02
B1817203 Error writing to Persistant Control Store (PCS) FSPSP02
B1817204 Error reading from PCS FSPSP02
B1817205 FSP Boot code failed during last boot causing the FSP to reset again FSPSP02
B1817206 FSP had a Unit check timer reset FSPSP02
B1817209 FSP had a Watchdog timeout reset FSPSP02
B181720A FSP had an internal hardware error FSPSP02
B1818103 Failed to write to registry Determine if service action or tracking event
B1818106 Invalid bus owner argument Determine if service action or tracking event
B1818107 Invalid number of command line arguments Determine if service action or tracking event
B1818108 No argument value for --r option Determine if service action or tracking event
B1818109 Multiple -c arguments Determine if service action or tracking event
B181810A -s option specified with –c Determine if service action or tracking event
B181810B Multiple -s arguments Determine if service action or tracking event
B181810C -c options specified with –s Determine if service action or tracking event
B181810D Invalid command line option Determine if service action or tracking event
B181810E Non-option element(s) Determine if service action or tracking event
B181810F Null input numeric string Determine if service action or tracking event
B1818110 Empty input numeric string Determine if service action or tracking event
B1818111 Invalid character encountered in conversion Determine if service action or tracking event
B1818114 Failed to stop instructions Determine if service action or tracking event
B1818115 Failed to send signal for event manager Determine if service action or tracking event
B1818116 Failed to get processor state Determine if service action or tracking event
B1818203 Requested index is out of range Determine if service action or tracking event
B1818204 Failed to open given directory Determine if service action or tracking event
B1818211 Could not understand operation requested Determine if service action or tracking event
B1818212 Unexpected result Determine if service action or tracking event
B1818213 Invalid data Determine if service action or tracking event
B1818214 Incorrect input size (too small or too large) Determine if service action or tracking event
B1818215 A generic stream failure has been detected Determine if service action or tracking event
B1818216 Failed to write to file Determine if service action or tracking event
B1818217 The Callout substructure cannot be identified Determine if service action or tracking event
B1818218 Unhandled signal received Determine if service action or tracking event
B1818301 Already in the terminate state Determine if service action or tracking event
B1818302 Already in the power off state Determine if service action or tracking event
B1818303 Currently processing a power off request from SPCN Determine if service action or tracking event
B1818304 Currently processing an FSP terminate request from another component Determine if service action or tracking event
B1818305 Failed state manager termination request Determine if service action or tracking event
B1818307 Failed power transition request Determine if service action or tracking event
B1818309 Too many client connections Determine if service action or tracking event
B181830B Thread timed out while waiting for another busy thread to complete Determine if service action or tracking event
B181830D Client request thread started with invalid pointer Determine if service action or tracking event
B181830E Another instance of the server is already running Determine if service action or tracking event
B1818310 Timed out waiting for thread conditional Determine if service action or tracking event
B1818312 Failed to receive on network Determine if service action or tracking event
B1818313 Failed to connect to server over network Determine if service action or tracking event
B1818316 Failed to trace SRC on termination trace Determine if service action or tracking event
B1818317 Failed to read the registry Determine if service action or tracking event
B1818318 Could not update the CEC termination state Determine if service action or tracking event
B181831A No log passed in. Will use default log to terminate system. Determine if service action or tracking event
B181831C Couldn't retrieve the embedded SRC from error log Determine if service action or tracking event
B181831D Failed to initialize thread attributes Determine if service action or tracking event
B181831E Failed to set deattach state for thread Determine if service action or tracking event
B1818320 Failed to bind socket Determine if service action or tracking event
B1818321 Failed to lock the mutex Determine if service action or tracking event
B1818322 Could not cancel all the client request processing threads Determine if service action or tracking event
B1818323 Unknown error Determine if service action or tracking event
B1818328 Could not unflatten log object from the received byte stream Determine if service action or tracking event
B1818329 Log size maximum is less than the client data length Determine if service action or tracking event
B181832A Zero data length Determine if service action or tracking event
B181832C Failed to construct event manager Determine if service action or tracking event
B1818330 Failed to bind socket Determine if service action or tracking event
B1818331 Failed to create thread Determine if service action or tracking event
B1818333 Cannot reset CEC termination in the middle of a power fault request Determine if service action or tracking event
B1818336 Unknown FSP role returned Determine if service action or tracking event
B1818337 Already in the terminated state with force failover option Determine if service action or tracking event
B1818338 Currently processing an FSP terminate request with force failover option from another component Determine if service action or tracking event
B1818341 Failed to flatten log Determine if service action or tracking event
B1818344 Bad length on flattened log Determine if service action or tracking event
B1818345 Server aborted or failed to connect to network Determine if service action or tracking event
B1818346 Server aborted or failed to send or receive on the network Determine if service action or tracking event
B1818347 Server not running Determine if service action or tracking event
B181834A P0 root path not defined Determine if service action or tracking event
B1818500 Incorrect number of arguments Determine if service action or tracking event
B1818501 The caller wanted to get event related data but the buffer pointer is invalid Determine if service action or tracking event
B1818502 The daemon received a message with an invalid function field Determine if service action or tracking event
B1818503 Error returned from another component Determine if service action or tracking event
B1818504 Failed system call Determine if service action or tracking event
B1818505 Failed fork system call Determine if service action or tracking event
B1818507 Error trying to forward an event to 1 or more subscribers Determine if service action or tracking event
B1818508 The id of a tool request is invalid Determine if service action or tracking event
B1818509 Unexpected signal received Determine if service action or tracking event
B181850E The user specified a time limit to wait for an event and limit was reached Determine if service action or tracking event
B181850F Another thread is waiting Determine if service action or tracking event
B1818600 Application has received an unexpected signal Determine if service action or tracking event
B181860D Application has not setup process error recovery Determine if service action or tracking event
B181860E Killing process without having process error recovery setup Determine if service action or tracking event
B181860F Process continues to get killed. Caught in a loop. Determine if service action or tracking event
B1818610 Application has received an unexpected signal Determine if service action or tracking event
B1818700 Error in selecting communicating socket Determine if service action or tracking event
B1818701 Failed to listen to socket for network server Determine if service action or tracking event
B1818702 Failed to bind to socket for network server Determine if service action or tracking event
B1818703 Failed to bind for TCP/IP Determine if service action or tracking event
B1818704 Error in accepting socket Determine if service action or tracking event
B1818705 Error in processing message from serial Determine if service action or tracking event
B1818706 Error in accepting socket Determine if service action or tracking event
B1818708 Error creating unique key for message queue Determine if service action or tracking event
B1818709 Error in creating message queue Determine if service action or tracking event
B181870A Error in queueing messages Determine if service action or tracking event
B181870B Error in receiving message from queue when processing message Determine if service action or tracking event
B181870C Failed to read registry Determine if service action or tracking event
B181870D Error in creating inbound thread Determine if service action or tracking event
B181870F Error in inbound connection Determine if service action or tracking event
B1818711 Error in receiving messages Determine if service action or tracking event
B1818714 Error processing message Determine if service action or tracking event
B1818718 Error in send message in DVS Determine if service action or tracking event
B181871B Failed to destroy old message queue Determine if service action or tracking event
B181871E Error in IPC address creation Determine if service action or tracking event
B181871F Error in closing inbound socket Determine if service action or tracking event
B1818728 Can't remove the previous mount Determine if service action or tracking event
B181872A Failed in registry read Determine if service action or tracking event
B181872C Failed in file write Determine if service action or tracking event
B181872E Can't activate user configuration setup file Determine if service action or tracking event
B1818730 Error in writing system name Determine if service action or tracking event
B1818731 Invalid user Determine if service action or tracking event
B1818736 Failed to set user password Determine if service action or tracking event
B1818737 Failed to validate password Determine if service action or tracking event
B1818738 Error in initial outbound remote thread setup Determine if service action or tracking event
B1818739 Failed to kill thread in outbound Determine if service action or tracking event
B181873A Failure from remote message object Determine if service action or tracking event
B181873B Failed to requeue message Determine if service action or tracking event
B181873C Error in operation should not kill Determine if service action or tracking event
B181873D Failed to destroy old message queue Determine if service action or tracking event
B181873F Failed to create thread Determine if service action or tracking event
B1818740 Failed to create thread Determine if service action or tracking event
B1818748 Failed to read from registry Determine if service action or tracking event
B181874C Serial message is invalid Determine if service action or tracking event
B1818752 Failed to open port for connection Determine if service action or tracking event
B1818753 Failed to configure baud for UART Determine if service action or tracking event
B1818755 Failed to set status field to failure for PHYP Determine if service action or tracking event
B1818756 Failed to verify dynamic password Determine if service action or tracking event
B1818759 Failed to write password signature Determine if service action or tracking event
B1818760 Failed to write Manufacturing password signature Determine if service action or tracking event
B1818762 Failed to configure parity for UART Determine if service action or tracking event
B1818763 Failed to configure UART to transmit normal Determine if service action or tracking event
B1818764 Failed to auto receive on UART Determine if service action or tracking event
B1818765 Failed to configure UART to transmit automatically Determine if service action or tracking event
B1818767 Error from perc Determine if service action or tracking event
B1818768 Error in getting machine type VPD Determine if service action or tracking event
B1818769 Error in getting machine serial number Determine if service action or tracking event
B181876A Error in reading machine brand name Determine if service action or tracking event
B181876B Error initializing network serial server daemon Determine if service action or tracking event
B181876C Failed to get a file descriptor Determine if service action or tracking event
B181876D Error from status of file Determine if service action or tracking event
B181876E Improper error path Determine if service action or tracking event
B181876F Failed to write Manufacturing password signature Determine if service action or tracking event
B1818770 Illegal socket descriptor selected Determine if service action or tracking event
B1818771 Improper error path Determine if service action or tracking event
B1818772 Failed to get registry key status information Determine if service action or tracking event
B1818773 Failed to get registry key status information Determine if service action or tracking event
B1818776 Failed to configure UART Determine if service action or tracking event
B1818777 Failed to configure UART for loop back Determine if service action or tracking event
B1818778 Failed to configure UART Determine if service action or tracking event
B1818780 Failed to read registry Determine if service action or tracking event
B1818781 Failed to open file Determine if service action or tracking event
B1818782 Failed to get file handle Determine if service action or tracking event
B1818783 Socket creation failed Determine if service action or tracking event
B1818785 Socket bind error Determine if service action or tracking event
B1818786 Failed in socket listen Determine if service action or tracking event
B1818787 Failed in file write Determine if service action or tracking event
B1818788 Invalid client name length Determine if service action or tracking event
B181878A Failure to get free entry Determine if service action or tracking event
B181878C Failed in registry read Determine if service action or tracking event
B181878D Update session entry failure Determine if service action or tracking event
B181878E Session entry read failed Determine if service action or tracking event
B181878F Invalid lookup entry for maximum entry Determine if service action or tracking event
B1818791 Failed to seek file offset Determine if service action or tracking event
B1818792 Session entry not found Determine if service action or tracking event
B1818793 Session entry read failed Determine if service action or tracking event
B1818795 Failed to seek session entry Determine if service action or tracking event
B1818796 Update session write failed Determine if service action or tracking event
B1818797 Invalid process id value Determine if service action or tracking event
B1818799 Invalid constructor area Determine if service action or tracking event
B181879A Failed in socket creation Determine if service action or tracking event
B181879B Failed to read path for socket from registry Determine if service action or tracking event
B181879D Failed to construct network client Determine if service action or tracking event
B181879E Failed to allocate memory for a message Determine if service action or tracking event
B181879F Failed to allocate memory for a message Determine if service action or tracking event
B18187A0 Length of the message buffer is incorrect Determine if service action or tracking event
B18187A1 Invalid pointer Determine if service action or tracking event
B18187A2 Invalid pointer Determine if service action or tracking event
B18187A3 Invalid pointer Determine if service action or tracking event
B18187A4 Invalid pointer Determine if service action or tracking event
B18187A5 Failed to get channel string id to server Determine if service action or tracking event
B18187A7 Failed to connect using UNIX Determine if service action or tracking event
B18187A8 Error in network connection using UNIX Determine if service action or tracking event
B18187AB Failed to receive data from the network client Determine if service action or tracking event
B18187AC Failed to connect using TCP/IP Determine if service action or tracking event
B18187AD Failed to connect using UNIX Determine if service action or tracking event
B18187AF Timed out waiting on connection Determine if service action or tracking event
B18187B0 Failed to get socket options Determine if service action or tracking event
B18187B1 Connection failed Determine if service action or tracking event
B18187B2 Failed to select socket Determine if service action or tracking event
B18187B3 Eth0 connection failure Determine if service action or tracking event
B18187B4 Failed to connect for network client serial connection to CMS Determine if service action or tracking event
B18187B6 Failed to send serial connection message to eth0 gateway Determine if service action or tracking event
B18187B7 Error in sending connection message Determine if service action or tracking event
B18187B8 Error in sending connection message to serial connection to CMS Determine if service action or tracking event
B18187B9 Failed to send data Determine if service action or tracking event
B18187BA Error in opening port number Determine if service action or tracking event
B18187BC Error writing to port Determine if service action or tracking event
B18187BD Failed to close UART Determine if service action or tracking event
B18187BE No object created Determine if service action or tracking event
B18187C0 Failed to receive data Determine if service action or tracking event
B18187C1 Failed to reset UART Determine if service action or tracking event
B18187CA Failed to close Determine if service action or tracking event
B18187CB Failed to close serial Determine if service action or tracking event
B18187CC Error closing eth0 connection Determine if service action or tracking event
B18187CD Error closing eth1 connection Determine if service action or tracking event
B18187D0 Unexpected signal received Determine if service action or tracking event
B18187D1 Error setting password Determine if service action or tracking event
B18187D6 Failed to send sdata Determine if service action or tracking event
B18187D7 Failed to send sdata Determine if service action or tracking event
B18187D8 Failed to configure UART Determine if service action or tracking event
B18187D9 Failed to configure UART Determine if service action or tracking event
B18187DA Failed to configure UART Determine if service action or tracking event
B18187DB Failed to configure UART Determine if service action or tracking event
B18187DC Failed to configure UART Determine if service action or tracking event
B18187DE Error receiving on serial interface Determine if service action or tracking event
B18187E5 Failed to read registry for network client Determine if service action or tracking event
B18187E6 Failed to connect for TCP/IP Determine if service action or tracking event
B18187E7 Socket error on select Determine if service action or tracking event
B18187E8 Timed out on select call Determine if service action or tracking event
B18187E9 Connect failed Determine if service action or tracking event
B18187EA Failed to close Determine if service action or tracking event
B18187EC Error in write operation Determine if service action or tracking event
B18187ED Error in select while waiting for data Determine if service action or tracking event
B18187EE Timeout in select while waiting for data Determine if service action or tracking event
B18187EF Error in receive operation Determine if service action or tracking event
B18187F0 Bad eyecatcher detected in the data packet Determine if service action or tracking event
B18187F1 Timeout in select while waiting for data Determine if service action or tracking event
B18187F2 Error in select while waiting for data Determine if service action or tracking event
B18187F3 Error in select Determine if service action or tracking event
B18187F5 Error in sending connection message to serial connection to CMS Determine if service action or tracking event
B18187F6 Error processing message for gateway Determine if service action or tracking event
B18187F7 Error sending or receiving message Determine if service action or tracking event
B18187FA Data sent in through constructor is bad Determine if service action or tracking event
B1818801 Invalid Service Routine Determine if service action or tracking event
B1818802 Requested processor core is not functional Determine if service action or tracking event
B1818803 Failed to get selected processor core functionality Determine if service action or tracking event
B1818806 Failed to restore the Attention Area into MainStore Determine if service action or tracking event
B1818807 Failed to restore the SPRs Determine if service action or tracking event
B1818808 Failed to restore the GPRs Determine if service action or tracking event
B1818809 Failed to create shared memory for Attention Area Determine if service action or tracking event
B181880A Failed to invalidate the I-Cache and Instruction buffers for all processors Determine if service action or tracking event
B181880B Failed to read path from registry Determine if service action or tracking event
B181880C Failed to start instructions to run the Service Routine Determine if service action or tracking event
B181880D Failed to write to Service Routine State in registry to indicate that a Service Routine is running Determine if service action or tracking event
B181880E Timed out waiting for the Service Routine to finish Determine if service action or tracking event
B181880F Failed to write to Service Routine State in registry to indicate that a Service Routine is not running Determine if service action or tracking event
B1818810 Failed to attach to shared memory area for Attention Area Determine if service action or tracking event
B1818813 Failed to set bit for SPR register setup Determine if service action or tracking event
B1818814 Failed to read GPRs for thread in User Data 2 of SRC so they could be saved Determine if service action or tracking event
B1818815 Failed to set bits in setup map buffer to indicate what register we wanted to set Determine if service action or tracking event
B1818816 Failed to read SPRs for thread in User Data 4 of SRC so they could be saved Determine if service action or tracking event
B1818817 Failed to read Attention Area from MainStore Determine if service action or tracking event
B1818818 Failed to get CPU Control Area from Host Data Area Determine if service action or tracking event
B1818819 Failed to get Service Routine structure from Host Data Area Determine if service action or tracking event
B181881A Failed to initialize Service Routine address buffer Determine if service action or tracking event
B181881B Failed to write Service Routine address to GPR3 for thread in User Data 2 of SRC Determine if service action or tracking event
B181881C Failed to read the current SPR values Determine if service action or tracking event
B181881D Failed to initialize NIA buffer Determine if service action or tracking event
B181881E Failed to setup SPR to run Service Routine Determine if service action or tracking event
B181881F Failed to set NIA for Service Routine Determine if service action or tracking event
B1818820 Failed to initialize MSR buffer Determine if service action or tracking event
B1818821 Failed to set MSR for Service Routine Determine if service action or tracking event
B1818822 Failed to set LPCR for Service Routine Determine if service action or tracking event
B1818823 Failed to clear RMI bit in LPCR for Service Routine Determine if service action or tracking event
B1818824 Failed to get LPCR from SPR object Determine if service action or tracking event
B1818825 Invalid attention area pointer was passed into function Determine if service action or tracking event
B1818826 Failed to get shared memory area for Attention Area Determine if service action or tracking event
B1818827 Failed to deattach from shared memory area for Attention Area Determine if service action or tracking event
B1818828 Failed to create file to signify that the system attention has been handled Determine if service action or tracking event
B1818829 Failed to destroy file Determine if service action or tracking event
B181882A Failed to destroy shared memory for Attention Area Determine if service action or tracking event
B181882B Failed to get status of thread requested Determine if service action or tracking event
B181882C No threads are alive on the requested processor core Determine if service action or tracking event
B181882D Failed to get proper fabric identity so we could read MainStore Determine if service action or tracking event
B181882E Failed to get Attention Area data from MainStore object Determine if service action or tracking event
B181882F Timed out waiting for Attention Handler to begin running Determine if service action or tracking event
B1818830 Failed to start Attention Handler Determine if service action or tracking event
B1818831 Failed to unmap memory Determine if service action or tracking event
B1818901 Failed to read from the registry Determine if service action or tracking event
B1818902 The Server file does not exist and we have timed out Determine if service action or tracking event
B1818903 The Server file exists, but is not locked and we have timed out Determine if service action or tracking event
B1818904 The file failed to open Determine if service action or tracking event
B1818905 The Server file failed to be created and opened Determine if service action or tracking event
B1818906 The Server file that was created/opened failed to lock Determine if service action or tracking event
B1818907 The Server file that was opened is already locked by another Server process Determine if service action or tracking event
B1818908 The Server file failed to be unlinked (destroyed) Determine if service action or tracking event
B181890A The List file is at the end of file Determine if service action or tracking event
B181890B The List file failed to read a line due to a reading error Determine if service action or tracking event
B181890C The List file is in an invalid format Determine if service action or tracking event
B181890D Failed to read the base path from the List file Determine if service action or tracking event
B181890E The timeout value read from the List file was too small or too large Determine if service action or tracking event
B181890F Failed to read the relative path of the file to be checked from the List file Determine if service action or tracking event
B1818910 Failed to read the timeout of the file to be checked from the List file Determine if service action or tracking event
B1818911 Failed to synchronize with a file from List file Determine if service action or tracking event
B1818912 Failed to synchronize with requested file in time allotted Determine if service action or tracking event
B1818913 A line was read from the List file, but it had invalid characters Determine if service action or tracking event
B1818914 The command was passed improper arguments Determine if service action or tracking event
B1818915 We have exceeded the maximum number of files that are allowed to be created and opened using Process Synchronization Determine if service action or tracking event
B1818916 The Server file descriptor could not be found Determine if service action or tracking event
B1818917 Failed to synchronize with requested file in time allotted Determine if service action or tracking event
B1818A01 Registry read or write failure due to an invalid key Determine if service action or tracking event
B1818A02 Registry read or write failure due to a size mismatch Determine if service action or tracking event
B1818A03 Building Block registry write failure Determine if service action or tracking event
B1818A04 Failed to determine the platform extension for the given write key Determine if service action or tracking event
B1818A05 Redundant write failed for the given key Determine if service action or tracking event
B1818A06 Event signal failure for the given write key Determine if service action or tracking event
B1818A08 Redundant registry write failure due to stream failure Determine if service action or tracking event
B1818A09 Building Block registry failure Determine if service action or tracking event
B1818A0A Error forming the registry path Determine if service action or tracking event
B1818A0D Requested system operation failed Determine if service action or tracking event
B1818A0E File not open Determine if service action or tracking event
B1818A0F Reached end of file Determine if service action or tracking event
B1818A10 Bad memory receive pointer Determine if service action or tracking event
B1818A11 Stream is at end of file Determine if service action or tracking event
B1818A12 File removal failed in the underlying layer Determine if service action or tracking event
B1818A13 File lock failure with given parameters Determine if service action or tracking event
B1818A15 Semaphore initialization cannot complete due to failure getting semaphore Determine if service action or tracking event
B1818A16 Semaphore initialization cannot complete due to control failure of semaphore Determine if service action or tracking event
B1818A17 Semaphore operation failed Determine if service action or tracking event
B1818A18 Semaphore initialization cannot complete due to failure getting file token Determine if service action or tracking event
B1818A19 Loading of a shared library has failed Determine if service action or tracking event
B1818A1A Loading of a shared library symbol has failed Determine if service action or tracking event
B1818A1B Failed to execute the synchronization immediate platform extension during a registry operation Determine if service action or tracking event
B1818A1D Building Block registry read failure Determine if service action or tracking event
B1818A1E Error reading platform extension for the given registry key Determine if service action or tracking event
B1819002 Invalid number of arguments were passed Determine if service action or tracking event
B1819003 Incorrect number of arguments Determine if service action or tracking event
B1819004 Failed trying to make a directory Determine if service action or tracking event
B1819008 Failed trying to get status of a file Determine if service action or tracking event
B1819009 Failed attempting to allocate memory Determine if service action or tracking event
B181900A Failed trying to allocate memory Determine if service action or tracking event
B181900B Failed trying to allocate memory Determine if service action or tracking event
B181900C Failed trying to memory map a file Determine if service action or tracking event
B181900E Failed trying to memory map a file Determine if service action or tracking event
B181900F Failed trying to unmap a file Determine if service action or tracking event
B1819010 Failure from memory unmap Determine if service action or tracking event
B1819011 Unexpected signal received Determine if service action or tracking event
B1819014 Size of registry entry is not correct Determine if service action or tracking event
B1819018 LID's file size is too large Determine if service action or tracking event
B181901A Failed trying to add another entry to an array Determine if service action or tracking event
B181901B Attempted to add a RAM FRU for an invalid mainstore area Determine if service action or tracking event
B181901C Failed trying to get status of primary LID's file Determine if service action or tracking event
B181901F More PHYP LIDs have been added to the build for FSP to load and an array is not large enough to accommodate the new LIDs Determine if service action or tracking event
B1819020 Size of file cannot contain the amount of memory we want to map Determine if service action or tracking event
B1819021 VPD says a required FRU does not exist Determine if service action or tracking event
B1819022 Attempted to allocate memory but it failed Determine if service action or tracking event
B1819023 No resource ids were returned for a required FRU Determine if service action or tracking event
B1819026 VPD collection was not complete and it did not complete in a reasonable time Determine if service action or tracking event
B1819027 An error occurred trying to DMA a LID to mainstore Determine if service action or tracking event
B1819028 The number of I/O paths to the primary FSP is not valid Determine if service action or tracking event
B181904F Another component had a failure Determine if service action or tracking event
B1819200 I/O control failed trying to set the DTR pin Determine if service action or tracking event
B1819202 HVSI received a response to the version query but did not get any data Determine if service action or tracking event
B1819203 OS protocol version does not match currently supported FSP version Determine if service action or tracking event
B1819206 The open on the requested device failed Determine if service action or tracking event
B1819207 HVSI was asked to open a port that did not exist Determine if service action or tracking event
B1819209 Invalid action requested or invalid data passed Determine if service action or tracking event
B181920A Request for modem control signal status but the port is not open Determine if service action or tracking event
B181920B Error trying to read status register data Determine if service action or tracking event
B181920D We failed reading data from the serial port Determine if service action or tracking event
B181920E Write to the serial port failed Determine if service action or tracking event
B181920F Failed to close Determine if service action or tracking event
B1819211 Stuck trying to write to serial port for more than 2 seconds Determine if service action or tracking event
B1819502 Unable to unlock an HMC queue mutex Determine if service action or tracking event
B1819505 Unable to post semaphore to wake up processing thread Determine if service action or tracking event
B1819506 Couldn't create the thread Determine if service action or tracking event
B1819509 The wrong number of bytes were written on mailbox interface Determine if service action or tracking event
B181950A No bytes were returned on mailbox read Determine if service action or tracking event
B181950B Failed to send message to PHYP Determine if service action or tracking event
B181950C Indicates that PHYP sent the service processor a bad size, modifier or HMC index Determine if service action or tracking event
B181950D The size of data being sent exceeds the TCE size or the TCE's have never been allocated and written to the registry Determine if service action or tracking event
B181950E Unable to start timer to block code update on DPO Determine if service action or tracking event
B1819510 Bad status in network response message Determine if service action or tracking event
B1819516 Got a socket message that doesn't belong to this sender Determine if service action or tracking event
B1819517 Unable to receive the error/event log from the daemon Determine if service action or tracking event
B1819518 Failed operating system call Determine if service action or tracking event
B1819519 Bad parameter for function Determine if service action or tracking event
B181951A IPL handshake failed Determine if service action or tracking event
B181951B Dump other than platform or FSP is being invalidated Determine if service action or tracking event
B1819520 State manager never made it to desired state in time we waited Determine if service action or tracking event
B1819521 HMC ID is too big Determine if service action or tracking event
B1819522 Daemon is down Determine if service action or tracking event
B1819524 Unable to clear bits in DSISR so PHYP may stop talking to the FSP, if the bits are actually set Determine if service action or tracking event
B1819525 Unable to display SRC for PHYP Determine if service action or tracking event
B1819526 On redundant FSPs, there are times when messages to PHYP are blocked and this is one of those times Determine if service action or tracking event
B1819527 On redundant FSPs, there are times when messages from PHYP are blocked and this is one of those times Determine if service action or tracking event
B1819902 Invalid signal received Determine if service action or tracking event
B1819903 An error occurred reading a registry variable Determine if service action or tracking event
B1819904 Failure to write to registry variable Determine if service action or tracking event
B1819905 Unrecognized power off IPL type Determine if service action or tracking event
B1819906 Invalid value read from registry variable Determine if service action or tracking event
B1819907 Invalid value trying to set registry variable to Determine if service action or tracking event
B1819908 An error occurred writing to the registry Determine if service action or tracking event
B1819909 Failure to write to registry for Controlled Power Off Determine if service action or tracking event
B181990A Failure to write to registry for Loss of AC Power Determine if service action or tracking event
B181A000 Input parameter is incorrect Determine if service action or tracking event
B181A001 Socket connect failure Determine if service action or tracking event
B181A004 Send system call has failed Determine if service action or tracking event
B181A005 Send length not equal to the message length Determine if service action or tracking event
B181A006 Received length not equal to the server message length Determine if service action or tracking event
B181A007 Invalid parameter Determine if service action or tracking event
B181A008 Socket system call failed for server socket Determine if service action or tracking event
B181A009 Bind system call has failed for server socket Determine if service action or tracking event
B181A00A Listen system call has failed for server socket Determine if service action or tracking event
B181A00B Failed to accept socket Determine if service action or tracking event
B181A00E Failed to receive message Determine if service action or tracking event
B181A00E Failed to receive message Determine if service action or tracking event
B181A00F Socket connect failure Determine if service action or tracking event
B181A010 Send system call failure Determine if service action or tracking event
B181A012 An error occurred reading the P0 root path from the registry Determine if service action or tracking event
B181A013 Trying to set invalid power state Determine if service action or tracking event
B181A015 Response doesn't match request Determine if service action or tracking event
B181A016 Incorrect mode Determine if service action or tracking event
B181A017 Function requested is disabled Determine if service action or tracking event
B181A018 Invalid subfunction number Determine if service action or tracking event
B181A019 Function range is disabled Determine if service action or tracking event
B181A01C Sequence error Determine if service action or tracking event
B181A01D Timer creation error Determine if service action or tracking event
B181A01E Resetting timer has failed Determine if service action or tracking event
B181A01F Resetting scroll lock has failed Determine if service action or tracking event
B181A021 Error in starting process as a daemon Determine if service action or tracking event
B181A024 Failure to start thread Determine if service action or tracking event
B181A025 Type undefined for given function. Probably invalid function number Determine if service action or tracking event
B181A027 Unexpected signal received Determine if service action or tracking event
B181A028 An unsupported event id was received Determine if service action or tracking event
B181A029 Failed to select socket Determine if service action or tracking event
B181A02A Timed out waiting for select Determine if service action or tracking event
B181A02B Failed to select socket Determine if service action or tracking event
B181A02C Timed out waiting for select Determine if service action or tracking event
B181A02E The client has gone away Determine if service action or tracking event
B181A02F The server has gone away Determine if service action or tracking event
B181A031 Failure building the display Determine if service action or tracking event
B181A032 Error while attempting to program panel buttons or displaying to Panel Determine if service action or tracking event
B181A033 Failed to read path from registry Determine if service action or tracking event
B181A036 Failed to remove an old message queue Determine if service action or tracking event
B181A038 Event message queue send failed Determine if service action or tracking event
B181A039 Event message queue receive failed Determine if service action or tracking event
B181A03A Failed to allocate memory for event Determine if service action or tracking event
B181A040 Failed thread conditional broadcast Determine if service action or tracking event
B181A041 Failed to create thread Determine if service action or tracking event
B181A042 Failed to synchronize with server process Determine if service action or tracking event
B181A043 An error occurred while reading a Registry value Determine if service action or tracking event
B181A044 Failed to synchronize with client process Determine if service action or tracking event
B181A049 VPNL returned error while executing the specified function Determine if service action or tracking event
B181A050 Error getting function state Determine if service action or tracking event
B181A051 The caller has elected to NOT wait for VPD collection to complete Determine if service action or tracking event
B181A054 The specified RID does not correspond to a physically present op-panel Determine if service action or tracking event
B181A055 An op-panel is currently active, and therefore the 'activate' request cannot be performed Determine if service action or tracking event
B181A056 Another concurrent maintenance operation is in progress Determine if service action or tracking event
B181A057 Failure to lock a mutex Determine if service action or tracking event
B181A058 Failure to unlock a mutex Determine if service action or tracking event
B181A059 An op-panel is not currently active, and therefore the 'deactivate' request cannot be performed Determine if service action or tracking event
B181A05A This event indicates that the panel will not be activated for the system because it is a redundant service processor, Model 570 with the new service processor cables Determine if service action or tracking event
B181A061 Failure to initialize thread attribute variable Determine if service action or tracking event
B181A062 Failure to set thread attribute variable Determine if service action or tracking event
B181A063 Failure to cancel thread Determine if service action or tracking event
B181A064 Failed to get VPD state Determine if service action or tracking event
B181A065 Failed to get the maximum number of RIDs from VPD Determine if service action or tracking event
B181A066 Failed to get RID number from VPD Determine if service action or tracking event
B181A069 More than one op-panel is physically present in the system Determine if service action or tracking event
B181A071 The caller's array is too small to contain all the data Determine if service action or tracking event
B181A072 Experienced a problem while trying to detect old message queue Determine if service action or tracking event
B181A073 Timed out waiting for the thread to exit Determine if service action or tracking event
B181A074 Error while waiting for thread to exit Determine if service action or tracking event
B181A075 Error waiting on the 'CCM complete' condition Determine if service action or tracking event
B181A076 Only the primary FSP can activate an op-panel Determine if service action or tracking event
B181A077 Failed to get power state Determine if service action or tracking event
B181A078 An error occurred trying to extract the Display SRC function symbol from the panel client library Determine if service action or tracking event
B181A079 An error occurred trying to setup the environment to have the correct library path for finding the panel client library Determine if service action or tracking event
B181A07A Error reading VPD Determine if service action or tracking event
B181A07B Invalid RID count Determine if service action or tracking event
B181A07C No sibling FSP found Determine if service action or tracking event
B181A201 Invalid field update specified in request Determine if service action or tracking event
B181A203 An unsupported operation was requested Determine if service action or tracking event
B181A204 Failed IPL request Determine if service action or tracking event
B181A206 Error returned from IPL lock function Determine if service action or tracking event
B181A207 Failed lamp test Determine if service action or tracking event
B181A208 Error returned while reading registry Determine if service action or tracking event
B181A209 Registry write failure Determine if service action or tracking event
B181A20A The operation request is not allowed because it was requested on the backup FSP Determine if service action or tracking event
B181A20B Invalid request from caller Determine if service action or tracking event
B181A20C This request has NULL output data pointer Determine if service action or tracking event
B181A20D Error returned from dump function Determine if service action or tracking event
B181A20E The requested function is not within the valid range or it is an unsupported function Determine if service action or tracking event
B181A20F Error from mailbox Determine if service action or tracking event
B181A211 Rejected specified function/ subfunction request Determine if service action or tracking event
B181A214 The requested function is not within the valid range or it is an unsupported function Determine if service action or tracking event
B181A215 SPCN Panel function (07) is disabled Determine if service action or tracking event
B181A216 FSP dump failed Determine if service action or tracking event
B181A217 Requested subfunction is outside the valid range Determine if service action or tracking event
B181A219 Invalid signal received by process Determine if service action or tracking event
B181B000 Invalid parameter passed by the user Determine if service action or tracking event
B181B001 Update for the given keyword not allowed for second time Determine if service action or tracking event
B181B004 Cannot find given record Determine if service action or tracking event
B181B005 VTOC record not found Determine if service action or tracking event
B181B006 Failure reading / finding the module VPD file Determine if service action or tracking event
B181B009 RLCA Index greater than number of RLCA entries Determine if service action or tracking event
B181B00A Invalid length of parameter Determine if service action or tracking event
B181B00B Failure to read VPD File Path registry Determine if service action or tracking event
B181B00C Error reading NVRAM entry Determine if service action or tracking event
B181B00E We had an error opening the file for the given resource ID Determine if service action or tracking event
B181B00F We were unable to gain a lock on a VPD file Determine if service action or tracking event
B181B010 We had an error reading the VPD file Determine if service action or tracking event
B181B011 We were unable to unlock the file Determine if service action or tracking event
B181B012 Unable to build location code for the FRU Determine if service action or tracking event
B181B013 Error trying to locate the file Determine if service action or tracking event
B181B014 Invalid format for the VPD Determine if service action or tracking event
B181B015 Error renaming file Determine if service action or tracking event
B181B016 We had an error closing and/or unlocking the file Determine if service action or tracking event
B181B017 Cannot find given keyword in the block Determine if service action or tracking event
B181B01B Cannot read VPD node for the given RID Determine if service action or tracking event
B181B01C Cannot find PT keyword in the VTOC record Determine if service action or tracking event
B181B01D Invalid input buffer length Determine if service action or tracking event
B181B01E Error while writing to the registry Determine if service action or tracking event
B181B01F Failure reading configurated id of machine model registry Determine if service action or tracking event
B181B020 Invalid parameter passed by the user Determine if service action or tracking event
B181B024 Error reading ECC for VHDR block Determine if service action or tracking event
B181B027 Invalid VTOC record length Determine if service action or tracking event
B181B028 We failed trying to get smart chip block size Determine if service action or tracking event
B181B02A Error initializing smart chips Determine if service action or tracking event
B181B02C There was a failure trying to update one of the smart chip blocks Determine if service action or tracking event
B181B030 Unable to find input resource ID in the RID table Determine if service action or tracking event
B181B031 Cannot find rlca index for the given location code Determine if service action or tracking event
B181B032 We were trying to generate a FRU callout because we had an error in one of the external interface and in process of generating that error we ran into another error Determine if service action or tracking event
B181B033 Cannot find MF tag for 1002 slotmap Determine if service action or tracking event
B181B035 Error writing Machine Brand registry Determine if service action or tracking event
B181B036 We failed trying to get smart chip block size Determine if service action or tracking event
B181B037 Invalid length for the keyword in the VPD Determine if service action or tracking event
B181B038 Invalid Block id passed by the user Determine if service action or tracking event
B181B03A Unable to find input resource ID in the RID table Determine if service action or tracking event
B181B03B Cannot find data port node for VRM information Determine if service action or tracking event
B181B03C Error initializing I2C devices Determine if service action or tracking event
B181B03D Writing to I2C device failed Determine if service action or tracking event
B181B03E Error trying to read the module VPD from the I2C Chip Determine if service action or tracking event
B181B03F Reading thermal sensor data failed for the given FRU Determine if service action or tracking event
B181B040 Invalid controller type for frequency controller Determine if service action or tracking event
B181B041 Someone has requested the SMP cable ID on a non MLx system Determine if service action or tracking event
B181B043 Invalid RID or invalid FSP ID Determine if service action or tracking event
B181B044 The Input RID does not have a redundant resource associated with it Determine if service action or tracking event
B181B045 Invalid bit definition for 9551 controllers Determine if service action or tracking event
B181B046 Invalid bit definition for 9552 controllers Determine if service action or tracking event
B181B049 Invalid data Determine if service action or tracking event
B181B04A Invalid keyword format VPD Determine if service action or tracking event
B181B04B Invalid description length for keyword format VPD Determine if service action or tracking event
B181B04C Invalid offset found in the keyword format VPD Determine if service action or tracking event
B181B04E Invalid offset Determine if service action or tracking event
B181B04F No 0x84 tag found Determine if service action or tracking event
B181B050 Invalid offset for the PT keyword in VTOC record Determine if service action or tracking event
B181B051 Invalid VTOC record offset Determine if service action or tracking event
B181B052 Invalid VHDR record size Determine if service action or tracking event
B181B053 Error reading "PR" keyword from the VINI record for the given RID Determine if service action or tracking event
B181B054 Invalid IN keyword size. Found zero number of VSRC entries Determine if service action or tracking event
B181B055 Zero plug count found for the given RID Determine if service action or tracking event
B181B056 Unsupported Resource Type Determine if service action or tracking event
B181B057 Unsupported Record Type Determine if service action or tracking event
B181B059 Offset is greater than buffer size Determine if service action or tracking event
B181B05A Invalid 200A Slotmap Determine if service action or tracking event
B181B05B Cannot find rlca index for the given slca index Determine if service action or tracking event
B181B05C Cannot find rlca index Determine if service action or tracking event
B181B05D Failure to write Registry with Raw VPD data Determine if service action or tracking event
B181B061 Unable to use either VPD Chip because we could not reach them or they are garded out Determine if service action or tracking event
B181B063 Incorrect size passed in by user Determine if service action or tracking event
B181B064 Caller has asked us to update an invalid type of FRU Determine if service action or tracking event
B181B065 Failed to read anchor card VPD Determine if service action or tracking event
B181B067 Error converting to multiple stanza format converged VPD Determine if service action or tracking event
B181B068 Error converting to multiple stanza format keyword format VPD Determine if service action or tracking event
B181B06D Failed to process VPD chip Determine if service action or tracking event
B181B06E Failed to get RLCA index for a resource ID Determine if service action or tracking event
B181B073 We read an invalid Machine Type Model from the VPD Determine if service action or tracking event
B181B07A Legacy SC buffer greater than original buffer Determine if service action or tracking event
B181B07C Cannot find old file in directory Determine if service action or tracking event
B181B07E Failed to write RLCA table Determine if service action or tracking event
B181B080 No valid Service Processor VPD was found on this system Determine if service action or tracking event
B181B082 No VPD collected for given processor card Determine if service action or tracking event
B181B083 Pin failure failed after root node mismatch Determine if service action or tracking event
B181B084 Pin failure is successful after root node mismatch Determine if service action or tracking event
B181B085 Invalid FRU Detect Data Port Type Found in VPD Determine if service action or tracking event
B181B086 We failed when trying to read the SMP cable ID from the 9552 controller on this MLx system Determine if service action or tracking event
B181B087 VPD Firmware had an error in trying to detect if this FRU was actually present or not on the system Determine if service action or tracking event
B181B088 No plug detect node found for this RID but the RLCA table said there should be Determine if service action or tracking event
B181B089 Error in finding out which FSP it is Determine if service action or tracking event
B181B08A We were unable to determine the maximum number of Resource ID's for the input FRU type Determine if service action or tracking event
B181B08B Failed trying to determine the Resource ID's associated with the given FRU type Determine if service action or tracking event
B181B08C We had a failure finding the LED node for this processor card Determine if service action or tracking event
B181B08D We had a failure reading the SMP cable ID on a processor card Determine if service action or tracking event
B181B08E We had a mismatch in the cable ID between two processor cards Determine if service action or tracking event
B181B08F There was a failure trying to configure 9555/9554 controller Determine if service action or tracking event
B181B090 There was a failure trying to create smart chip blocks Determine if service action or tracking event
B181B091 Error occurred while locking/unlocking DASD device Determine if service action or tracking event
B181B092 VPD Firmware had an error in trying to read the size of a registry key Determine if service action or tracking event
B181B093 Failed to open source directory while copying a directory Determine if service action or tracking event
B181B094 Locking the VPD file has failed Determine if service action or tracking event
B181B095 Unlocking the VPD file has failed Determine if service action or tracking event
B181B097 Cannot find DR keyword in the given record while updating legacy smart chip VPD Determine if service action or tracking event
B181B098 TM field is already updated once. Second update for the given keyword not allowed because TYPE part of MTM does not match Determine if service action or tracking event
B181B099 Firmware needs to add support for an additional resource to the given FRU type Determine if service action or tracking event
B181B09A Failed to get FRU status for the given RID in registry update function Determine if service action or tracking event
B181B09B Failed to read the VPD and update the registry entry for the input RID Determine if service action or tracking event
B181B09C Error writing NVRAM to VPD Determine if service action or tracking event
B181B09D Mismatch in VPD vs NVRAM Determine if service action or tracking event
B181B09E Failed to write System NVRAM values out to VPD Determine if service action or tracking event
B181B09F Failed to write Enclosure NVRAM values out to VPD Determine if service action or tracking event
B181B0A0 Unable to add FRU to the rlcaTable because instanceTable shows no more FRU addition allowed Determine if service action or tracking event
B181B0A1 Invalid algorithm type found in the VPD node for the given RID in the rlcaTable Determine if service action or tracking event
B181B0A2 Failed to update GARD with a resource ID Determine if service action or tracking event
B181B0A3 Failed to GARD out a resource ID Determine if service action or tracking event
B181B0A4 Failed to determine if chip is garded out or not Determine if service action or tracking event
B181B0A5 A chip on the Anchor card has been garded out Determine if service action or tracking event
B181B0A7 Failure to write registry for update status Determine if service action or tracking event
B181B0A8 Failure attempting to read the system configuration file Determine if service action or tracking event
B181B0A9 Failed to input line from system file Determine if service action or tracking event
B181B0AA Mismatch SN or PN between primary and redundant fsp recollect during VPD verification Determine if service action or tracking event
B181B0AB Error reading smart chip legacy block size Determine if service action or tracking event
B181B0AD Error reading Raw Machine type model registry Determine if service action or tracking event
B181B0AF Failed to process message for VPD Determine if service action or tracking event
B181B0B5 Cannot find RID for FRU_SP for this FSP Determine if service action or tracking event
B181B0B6 Error synchronizing file to the other FSP Determine if service action or tracking event
B181B0B7 Error reading system type registry Determine if service action or tracking event
B181B0B8 Error converting FRU type Determine if service action or tracking event
B181B0B9 Error converting FRU type Determine if service action or tracking event
B181B0BB Sibling FSP state is set to NOT working Determine if service action or tracking event
B181B0BC Unable to locate string in file Determine if service action or tracking event
B181B0BD Invalid number of processor cards are present Determine if service action or tracking event
B181B0BE Checksum in the VPD data does not match calculated checksum Determine if service action or tracking event
B181B0BF Someone tries to read/write a keyword in corrupt VPD Determine if service action or tracking event
B181B0C0 Failure in getting the other RID from the system configuration file Determine if service action or tracking event
B181B0C1 Error in updating CCMM registry with the new primary RID Determine if service action or tracking event
B181B0C2 VPD is not collected both for primary RID and redundant RID or its child RID Determine if service action or tracking event
B181B0C4 Failed to read GPIO pin value from FSP extender Determine if service action or tracking event
B181B0C5 Invalid number rlcaTable entries Determine if service action or tracking event
B181B0C6 New value has been written to the hyperboot capability registry Determine if service action or tracking event
B181B0C7 Error while getting the hyperboot capability registry value Determine if service action or tracking event
B181B0C8 VPD could not collect more Oppanel VPD for ASMI Determine if service action or tracking event
B181B0C9 No Oppanels present in system Determine if service action or tracking event
B181B0CA Invalid raw brand name Determine if service action or tracking event
B181B0CB Failed to copy or rename directory Determine if service action or tracking event
B181B0CC Failed to remove directory Determine if service action or tracking event
B181B101 VPD indicates that no VPD headers are available Determine if service action or tracking event
B181B102 Location code for the associated resource ID not found in the VPD header array Determine if service action or tracking event
B181B103 Location code for the associated resource ID is not NULL terminated Determine if service action or tracking event
B181B104 Parent location code of resource ID being processed is not null terminated Determine if service action or tracking event
B181B105 The length of the location code being built is going to exceed the maximum allowed Determine if service action or tracking event
B181B106 Call made to read location code for a resource ID of zero Determine if service action or tracking event
B181B107 Call made to read location code, but the buffer provided is not large enough to hold a maximum length location code Determine if service action or tracking event
B181B108 Location code for the associated resource ID has a length mismatch Determine if service action or tracking event
B181B109 Call made to read location code, but the buffer reference provided was a NULL pointer Determine if service action or tracking event
B181B10B Failed to get number of headers from VPD Determine if service action or tracking event
B181B10C Failed to get all headers from VPD Determine if service action or tracking event
B181B10D Failed to process a resource ID Determine if service action or tracking event
B181B10E Failed to get maximum number of RIDs for enclosure Determine if service action or tracking event
B181B10F Failed to get RID numbers for enclosure Determine if service action or tracking event
B181B110 Failed to get enclosure number and index using RID Determine if service action or tracking event
B181B111 Error reading enclosure Feature Code and model data Determine if service action or tracking event
B181B112 Error reading system Type/Model data Determine if service action or tracking event
B181B113 Error reading system serial number data Determine if service action or tracking event
B181B114 Error updating location code Determine if service action or tracking event
B181B115 Failed to get RID number of children Determine if service action or tracking event
B181B116 Maximum number of RIDs returned is zero Determine if service action or tracking event
B181B117 Data length mismatch while reading enclosure Feature Code and model data Determine if service action or tracking event
B181B118 Data length mismatch while reading enclosure serial number data Determine if service action or tracking event
B181B119 Data length mismatch while reading system type/model data Determine if service action or tracking event
B181B11A Data length mismatch while reading system serial number data Determine if service action or tracking event
B181B11B Failed to read rlca table from VPD Determine if service action or tracking event
B181B11C The rlca was searched for a FRU_ID of "VV" which is the starting point of the VPD tree. However, no "VV" entry was found in the rlca Determine if service action or tracking event
B181B11D An FRU_ID "VV" root was being processed and an error was returned Determine if service action or tracking event
B181B11E An enclosure was being processed and an error was returned Determine if service action or tracking event
B181B11F User input invalid parameter Determine if service action or tracking event
B181B120 Error returned from reading VPD registry Determine if service action or tracking event
B181B121 Could not find VPD registry entry Determine if service action or tracking event
B181B201 Call was made to read location codes, but a NULL buffer pointer was provided Determine if service action or tracking event
B181B202 Call was made to read location codes, but the input buffer provided is not large enough to hold all the LED location codes Determine if service action or tracking event
B181B204 Call was made to get LED access data, but the input location code pointer was NULL Determine if service action or tracking event
B181B205 Call was made to get LED access data, but the input location code was not NULL terminated Determine if service action or tracking event
B181B207 Call was made drive an LED to a specific state but the class controller type is invalid or not supported Determine if service action or tracking event
B181B208 Failed to open I2C bus Determine if service action or tracking event
B181B209 Failed to close I2C bus Determine if service action or tracking event
B181B20A Failed to transmit data on I2C bus Determine if service action or tracking event
B181B20B Failed to transmit data to the LED lightstrip controller Determine if service action or tracking event
B181B20C Failed to lock the I2C hub Determine if service action or tracking event
B181B20D The specified LED state is not valid Determine if service action or tracking event
B181B20E Failed to get GMNOL from VPD Determine if service action or tracking event
B181B20F Failed to get GAL from VPD Determine if service action or tracking event
B181B210 Call was made to read the number of enclosure LEDs, but none was found Determine if service action or tracking event
B181B211 Failed to read LED location codes Determine if service action or tracking event
B181B212 Failed to drive LED to specified state Determine if service action or tracking event
B181B213 Failed to drive LED to specified state Determine if service action or tracking event
B181B214 Failed to transmit data to the I2C hub Determine if service action or tracking event
B181B215 Failed to transmit park data to the I2C hub Determine if service action or tracking event
B181C000 VPD failure Determine if service action or tracking event
B181C001 Session entry failure Determine if service action or tracking event
B181C002 Failed network client call Determine if service action or tracking event
B181C003 Invalid authentication level or requestor was set Determine if service action or tracking event
B181C004 PHyp returned an error when attempting to open a PHyp session Determine if service action or tracking event
B181C005 Data buffer error Determine if service action or tracking event
B181C006 Failed Mailbox function call Determine if service action or tracking event
B181C007 Failed to read from or write to a registry entry Determine if service action or tracking event
B181C008 Internal event error Determine if service action or tracking event
B181C009 Internal file error Determine if service action or tracking event
B181C00A Internal VTTY error Determine if service action or tracking event
B181C00B Failed to signal a broadcast event Determine if service action or tracking event
B181C00C Failed to successfully create a virtual serial object while running the virtual serial open command Determine if service action or tracking event
B181C00D A virtual serial client attempted to open a virtual serial session before PHYP reached standby/runtime state Determine if service action or tracking event
B181C00E The DMA component returned an error log while attempting to read the VTTY buffer Determine if service action or tracking event
B181C00F Received an error while trying to access the leds file Determine if service action or tracking event
B181C010 Received an error while accessing the semaphore object for the leds table during the lock table command Determine if service action or tracking event
B181C011 API error Determine if service action or tracking event
B181C012 Failure to calculate the timestamp stored in the session entry object Determine if service action or tracking event
B181C013 Failed to acknowledge surveillance Determine if service action or tracking event
B181C014 Internal lock error Determine if service action or tracking event
B181C015 Failed to obtain file lock Determine if service action or tracking event
B181C016 Failed to release file lock Determine if service action or tracking event
B181C017 Failed to access a file through the utility Determine if service action or tracking event
B181C018 Unable to authenticate password for an authorized virtual serial session Determine if service action or tracking event
B181C019 Failed to reset reload Determine if service action or tracking event
B181C01A PHYP status error Determine if service action or tracking event
B181C01B HMC/FSP interface protocol violation Determine if service action or tracking event
B181C01C Internal error Determine if service action or tracking event
B181C01D Protocol error Determine if service action or tracking event
B181C01E Failed to get the cage and frame number Determine if service action or tracking event
B181C01F Did not receive a valid data length or ack value Determine if service action or tracking event
B181C020 MP command cannot be executed since MP state is incorrect Determine if service action or tracking event
B181C021 Failed to write partial lid for code update Determine if service action or tracking event
B181C022 Internal error Determine if service action or tracking event
B181C023 Precondition failure Determine if service action or tracking event
B181C024 Request to open a PHyp connection was denied because the tool type is not allowed to perform that operation Determine if service action or tracking event
B181C025 Concurrent maintenance lock access failure Determine if service action or tracking event
B181D101 Failed to write to file Determine if service action or tracking event
B181D102 Failed to read breakpoint attention Determine if service action or tracking event
B181D103 File write operation failed Determine if service action or tracking event
B181D107 Failed to initialize the Hypervisor service routine flag Determine if service action or tracking event
B181D108 Failed to read from registry Determine if service action or tracking event
B181D10A Null pointer while trying to enable attentions Determine if service action or tracking event
B181D10C Failure in Unmask attentions interface Determine if service action or tracking event
B181D10D JTAG failed while waiting for attention Determine if service action or tracking event
B181D10E Failed to write to MainStore Determine if service action or tracking event
B181D10F JTAG read failure while reading the Interrupt Status Register Determine if service action or tracking event
B181D110 Fail to get the Hardware level in the JTAG controller Determine if service action or tracking event
B181D111 Failed to enable attentions Determine if service action or tracking event
B181D112 Timeout while waiting for JTAG lock Determine if service action or tracking event
B181D113 Request for system dump failed after getting attention Determine if service action or tracking event
B181D115 Utility read failure on a breakpoint attention Determine if service action or tracking event
B181D116 Utility write failure while writing the terminate flag Determine if service action or tracking event
B181D117 Failure while trying to open a file on a breakpoint attention Determine if service action or tracking event
B181D118 Phyp wrote an invalid SRC in the attention area in MainStore Determine if service action or tracking event
B181D119 Master FSP Communications failure Determine if service action or tracking event
B181D11A Utility write failure while writing the terminate flag Determine if service action or tracking event
B181D11C Spurious attention detected after attempt to clear all attentions for ISR Determine if service action or tracking event
B181D11D Failed to get the reserve Determine if service action or tracking event
B181D11E Failed while attempting to release the reserve Determine if service action or tracking event
B181D11F No error created on a processor checkstop Determine if service action or tracking event
B181D120 Failed to read mainstore after a breakpoint attention Determine if service action or tracking event
B181D121 Failed to write to mainstore after a breakpoint attention Determine if service action or tracking event
B181D122 Failed to write the ISR back to the JTAG controller Determine if service action or tracking event
B181D123 Failed to release the JTAG lock Determine if service action or tracking event
B181D124 Failure when getting functional group Determine if service action or tracking event
B181D125 Failure while mapping mainstore to get attention area Determine if service action or tracking event
B181D126 Failed while reading the mainstore area Determine if service action or tracking event
B181D127 Get data failure Determine if service action or tracking event
B181D128 Failure to instantiate an object Determine if service action or tracking event
B181D129 Attentions not found exceeded threshold Determine if service action or tracking event
B181D12A Server process failed Determine if service action or tracking event
B181D12B Interface failure Determine if service action or tracking event
B181D12C Interface failure Determine if service action or tracking event
B181D12D Interface failure Determine if service action or tracking event
B181D12E Disable attentions failed Determine if service action or tracking event
B181D130 Interface failure on an asset protection attention Determine if service action or tracking event
B181D131 A trace trigger attention was detected Determine if service action or tracking event
B181D132 Detected a clock stop on error attention Determine if service action or tracking event
B181D133 Server process failed Determine if service action or tracking event
B181D134 Failed to synchronize with client process Determine if service action or tracking event
B181D135 Utility read failed to read the current state of the State Manager Determine if service action or tracking event
B181D136 Invalid type of attention Determine if service action or tracking event
B181D137 A TI was detected during either dump, power off or dump transition Determine if service action or tracking event
B181D138 Manufacturing interface to read the policy flag failed Determine if service action or tracking event
B181D139 Call to generate event failed during a Non IO checkstop Determine if service action or tracking event
B181D13A Utility read failed to read the current role of the FSP Determine if service action or tracking event
B181D13B FSP Dump event timed out Determine if service action or tracking event
B181D13C Reset reload while handling P5IOC recovered error Determine if service action or tracking event
B181E001 Call home enabled but no destination phone numbers programmed Determine if service action or tracking event
B181E002 Failed to receive message Determine if service action or tracking event
B181E003 Pager data was not programmed Determine if service action or tracking event
B181E004 Error writing to serial port Determine if service action or tracking event
B181E005 The customer AGN account information is missing Determine if service action or tracking event
B181E006 Missing data from setup Determine if service action or tracking event
B181E007 Failed fork system call Determine if service action or tracking event
B181E008 Failed to rebuild the error log during call home Determine if service action or tracking event
B181E009 Failed fork system call Determine if service action or tracking event
B181E00A Child process failed Determine if service action or tracking event
B181E00B Child process failed Determine if service action or tracking event
B181E00C Child process died due to unhandled signal Determine if service action or tracking event
B181E00D Child process died due to unhandled signal Determine if service action or tracking event
B181E00E Failed trying to put the symptom string together Determine if service action or tracking event
B181E010 Serial port open failed Determine if service action or tracking event
B181E011 The file descriptor was is not valid Determine if service action or tracking event
B181E012 Failed select system call Determine if service action or tracking event
B181E015 Sending message on socket failed Determine if service action or tracking event
B181E016 Failed to get socket Determine if service action or tracking event
B181E017 Failed to get socket Determine if service action or tracking event
B181E01E Call home test Determine if service action or tracking event
B181E01F User issued a call home test Determine if service action or tracking event
B181E025 Failed serial port echo Determine if service action or tracking event
B181E026 Failed serial port echo Determine if service action or tracking event
B181E027 Trying to do call home test on same port that ASMI is active on Determine if service action or tracking event
B181E028 Trying to do call home test on same port that ASMI is active on Determine if service action or tracking event
B181E101 String was found in the input data and the system reIPL has been requested Determine if service action or tracking event
B181E201 Received an error and did not attempt a reboot Determine if service action or tracking event
B181E202 Received an error waiting for the backup FSP to terminate Determine if service action or tracking event
B181E303 Invalid modifier Determine if service action or tracking event
B181E30B Cannot Query for LED Table Determine if service action or tracking event
B181E30D The request sent in is not a valid request type for this function Determine if service action or tracking event
B181E310 Invalid request type Determine if service action or tracking event
B181E315 Failed on retry for SPCN command Determine if service action or tracking event
B181E31B Failed to get LED state control Determine if service action or tracking event
B181E31C SPCN PRS command to collect LED data did not return any data Determine if service action or tracking event
B181E31D SPCN command to control the physical attention LED has failed Determine if service action or tracking event
B181E31E Failed to get location code table from PHYP Determine if service action or tracking event
B181E400 Attempt to open file failed Determine if service action or tracking event
B181E401 Attempt to open file failed Determine if service action or tracking event
B181E402 Attempt to open file failed Determine if service action or tracking event
B181E403 Attempt to close file failed Determine if service action or tracking event
B181E404 Attempt to close file failed Determine if service action or tracking event
B181E405 Attempt to open file failed Determine if service action or tracking event
B181E406 Attempt to open file failed Determine if service action or tracking event
B181E407 Attempt to open file failed Determine if service action or tracking event
B181E408 Attempt to close file failed Determine if service action or tracking event
B181E409 Attempt to close file failed Determine if service action or tracking event
B181E40A Detected DRAM Recovered Errors Determine if service action or tracking event
B181E40B Detected NVRAM Recovered Errors Determine if service action or tracking event
B181E40C Failed to get statistics Determine if service action or tracking event
B181E40D Attempt to open directory failed Determine if service action or tracking event
B181E40E Attempt to open file failed Determine if service action or tracking event
B181E40F File system corrupted Determine if service action or tracking event
B181E411 Failed to get the maximum number of RIDs from VPD Determine if service action or tracking event
B181E412 Failed to get the RID from VPD Determine if service action or tracking event
B181E425 Failed to initialize thread attributes Determine if service action or tracking event
B181E426 Failed to set thread to deattached state Determine if service action or tracking event
B181E427 Attempt to accept a client request failed Determine if service action or tracking event
B181E428 Attempt to receive client message failed Determine if service action or tracking event
B181E429 Failed to send response to client Determine if service action or tracking event
B181E42A Unknown client command received Determine if service action or tracking event
B181E42F Another instance of the process is already running Determine if service action or tracking event
B181E430 Failed thread call Determine if service action or tracking event
B181E432 System call for mutex failed Determine if service action or tracking event
B181E436 Client failed to send its heartbeat message within the stipulated time Determine if service action or tracking event
B181E437 Error while trying to connect to the daemon Determine if service action or tracking event
B181E438 Error while trying send or receive data with the daemon Determine if service action or tracking event
B181E439 Failed to synchronize with server Determine if service action or tracking event
B181E43A Failed fork system call Determine if service action or tracking event
B181E43B Could not close the client socket Determine if service action or tracking event
B181E43C Error while attempting to close server address socket Determine if service action or tracking event
B181E43D Failed to read path from registry Determine if service action or tracking event
B181E43E Error while trying to signal event to notify HMC of the change in the HMC Surveillance Flag Determine if service action or tracking event
B181E43F Error returned while attempting to write to the registry Determine if service action or tracking event
B181E440 Error returned when attempting to read the registry Determine if service action or tracking event
B181E441 Error trying to notify PHYP of the change in HMC flag Determine if service action or tracking event
B181E443 Invalid type Determine if service action or tracking event
B181E444 Could not flatten log to send to client Determine if service action or tracking event
B181E445 Error while attempting to extract flattened log sent from the daemon Determine if service action or tracking event
B181E446 Client gateway was not able to talk to the master FSP Determine if service action or tracking event
B181E448 Gateway address creation to send surveillance heart beat to master FSP failed Determine if service action or tracking event
B181E449 Failed to connect to client gateway Determine if service action or tracking event
B181E44A Failed to kill the Common Message Server of a failed HMC client Determine if service action or tracking event
B181E44F Error while trying to reset the watchdog timer Determine if service action or tracking event
B181E451 Failed to query managed information Determine if service action or tracking event
B181E453 Attempt to bind to the listening address failed Determine if service action or tracking event
B181E454 Attempt to listen in server address failed Determine if service action or tracking event
B181E455 Attempt to open directory failed Determine if service action or tracking event
B181E457 The mux id requested to ping is not valid Determine if service action or tracking event
B181E458 Another component had an error Determine if service action or tracking event
B181E45B Error while attempting to create listening socket Determine if service action or tracking event
B181E45C Invalid Response Interval sent Determine if service action or tracking event
B181E45D Error while trying to create server address Determine if service action or tracking event
B181E460 Failed to set thread schedule policy Determine if service action or tracking event
B181E462 Failed to get the maximum allowed thread priority Determine if service action or tracking event
B181E463 Failed to get the scheduling parameter Determine if service action or tracking event
B181E464 Failed to set scheduling parameter to thread Determine if service action or tracking event
B181E500 Bad hardware Determine if service action or tracking event
B181E601 Error while attempting to read registry Determine if service action or tracking event
B181E602 Another process is already running Determine if service action or tracking event
B181E604 Network client failed to send or receive Determine if service action or tracking event
B181E606 Invalid major operation received Determine if service action or tracking event
B181E607 Error while attempting to create listening socket Determine if service action or tracking event
B181E608 Failed to send from network server Determine if service action or tracking event
B181E609 Failed fork system call Determine if service action or tracking event
B181E60A Error returned while initializing a thread attribute Determine if service action or tracking event
B181E60B Error returned while setting a thread attribute Determine if service action or tracking event
B181E60C Error returned while creating a thread Determine if service action or tracking event
B181E60F Received an invalid component type while attempting to create handler thread Determine if service action or tracking event
B181E610 Network client failed to connect Determine if service action or tracking event
B181E611 Network client failed to send or receive Determine if service action or tracking event
B181E612 Network client failed to close Determine if service action or tracking event
B181E613 Failed to synchronize with server Determine if service action or tracking event
B181E614 Failed to bind to socket Determine if service action or tracking event
B181E615 Failed to listen to socket Determine if service action or tracking event
B181E616 Network server failed to connect Determine if service action or tracking event
B181E618 Failed to initialize mutex Determine if service action or tracking event
B181E619 Error encountered while locking mutex Determine if service action or tracking event
B181E61A Error encountered while unlocking mutex Determine if service action or tracking event
B181E61B Network server failed to close Determine if service action or tracking event
B181E61C Failed to return log Determine if service action or tracking event
B181E61D Unknown minor operation id received Determine if service action or tracking event
B181E620 Invalid operation requested to data correlation handler Determine if service action or tracking event
B181E621 Failed to create object Determine if service action or tracking event
B181E622 Network client failed to close Determine if service action or tracking event
B181E623 Network client failed to send or receive Determine if service action or tracking event
B181E625 No file name sent in by client Determine if service action or tracking event
B181E627 Non existent registry variable sent Determine if service action or tracking event
B181E628 File does not exist Determine if service action or tracking event
B181E629 Error attempting to open file for reading or writing Determine if service action or tracking event
B181E62A Error while reading file Determine if service action or tracking event
B181E62B Error while attempting write registry Determine if service action or tracking event
B181E62C Error while writing to the file Determine if service action or tracking event
B181E62D Backup is not running from the same flash side as primary FSP Determine if service action or tracking event
B181E62F Sibling returned error on the requested operation Determine if service action or tracking event
B181E633 Error returned while attempting to create event handler object Determine if service action or tracking event
B181E634 Invalid event id was received Determine if service action or tracking event
B181E635 Error while attempting to signal Fsp Role Change event Determine if service action or tracking event
B181E64A Backup FSP has a different level that the primary FSP Determine if service action or tracking event
B181E64B Primary and backup FSP have different lid levels loaded Determine if service action or tracking event
B181E64C Error returned when a flattened log was attempted to be restored Determine if service action or tracking event
B181E64D Error unflattening the log sent by primary FSP Determine if service action or tracking event
B181E64F Invalid role in the FSP Determine if service action or tracking event
B181E650 Invalid fail-over type requested Determine if service action or tracking event
B181E656 MUX control could not be taken Determine if service action or tracking event
B181E657 Unrecognized routing type received Determine if service action or tracking event
B181E659 Requested IPL failed Determine if service action or tracking event
B181E65B Failed to determine fail-over type Determine if service action or tracking event
B181E65C Surveillance failure of primary FSP detected at pre-standby state Determine if service action or tracking event
B181E65F Error attempting to determine if the current platform can support redundant FSP Determine if service action or tracking event
B181E660 The system is in a state where fail-over operation cannot be initiated Determine if service action or tracking event
B181E661 Sibling returned error on the requested operation Determine if service action or tracking event
B181E663 Fail-over operation is not allowed Determine if service action or tracking event
B181E664 Force Terminate and fail-over operation is requested Determine if service action or tracking event
B181E665 Failed to terminate and force a fail-over Determine if service action or tracking event
B181E666 Requested FSP IPL failed Determine if service action or tracking event
B181E667 Invalid IPL type Determine if service action or tracking event
B181E669 Failed to determine fail-over type Determine if service action or tracking event
B181E66B Synchronization for redundancy was stopped. Determine if service action or tracking event
B181E66D AFO request received from primary FSP Determine if service action or tracking event
B181E66E EFO operation is being performed by backup to take control of the host system Determine if service action or tracking event
B181E66F Non I/O Path fail EFO operation is being performed by backup to take control of the host system Determine if service action or tracking event
B181E678 Error while obtaining mux control Determine if service action or tracking event
B181E67B Failed to close I2C ADAL Determine if service action or tracking event
B181E683 Error while attempting to read Fsp Role registry Determine if service action or tracking event
B181E684 Sibling returned error on the requested operation Determine if service action or tracking event
B181E686 Error in connecting to address to talk to the Common Message Server of a failed HMC client Determine if service action or tracking event
B181E687 Failed to kill the Common Message Server of a failed HMC client Determine if service action or tracking event
B181E689 Sibling returned error on the requested operation Determine if service action or tracking event
B181E68A The fail-over enable key has been changed by HMC Determine if service action or tracking event
B181E68B Sibling has requested to initiate reset/reload operation Determine if service action or tracking event
B181E68C Powering off primary FSP to get the hardware muxes released Determine if service action or tracking event
B181E68F Backup FSP is not at Runtime Determine if service action or tracking event
B181E690 Fail-over cannot be enabled at runtime without having a backup that has not IPLed the system even once Determine if service action or tracking event
B181E692 Error trying to get FSP alpha version key Determine if service action or tracking event
B181E693 Failed check for fail-over capable Determine if service action or tracking event
B181E699 Unknown HMC command received Determine if service action or tracking event
B181E69D Attempt to restart discovery command received Determine if service action or tracking event
B181E712 This SRC can occur on a system in a 24" rack for either of two reasons:
  • A BPC had its sync settings cleared
  • The system had a single BPC that had the CEC name updated many times (a counter rolled) before a second BPC was installed, or brought back on-line.
This error can be cleared by setting the CEC name via the HMC. This will re-initialize the registry that tells sync which BPA has the newer data.
B181E801 Failure to read from or write to registry Determine if service action or tracking event
B181E802 Failed to synchronize with client Determine if service action or tracking event
B181E803 Failure with network server Determine if service action or tracking event
B181E804 Thread failure Determine if service action or tracking event
B181E805 Client failure Determine if service action or tracking event
B181E806 Failure when calling Code Update Determine if service action or tracking event
B181E807 Failure from Mailbox function Determine if service action or tracking event
B181E808 Failure to read or write using DMA for SMA Dump Header Determine if service action or tracking event
B181E809 The SMAs that were selected to perform an MP Fatal Dump did not all complete successfully Determine if service action or tracking event
B181E80A System Type was not recognized Determine if service action or tracking event
B181E80B Failure in Load IPC Bootstrap execution Determine if service action or tracking event
B181E80C Null pointer while iterating through the SMAs Determine if service action or tracking event
B181E80D Received invalid initialization type input Determine if service action or tracking event
B181E80E The MP reset procedure failed Determine if service action or tracking event
B181E80F The MP reset procedure failed Determine if service action or tracking event
B181E810 The MP reset procedure failed Determine if service action or tracking event
B181E811 The MP reset procedure failed Determine if service action or tracking event
B181E812 Failure to find a matching SMA Handle for the inputted SMA id Determine if service action or tracking event
B181E813 Received a command to invalidate an SMA Dump when no SMA Dump was present Determine if service action or tracking event
B181E814 Failure in dump utility that reads and formats System Type, Model, and Feature Code Determine if service action or tracking event
B181E815 Failure in attempting to signal event Determine if service action or tracking event
B181E81F Test of log failed Determine if service action or tracking event
B181E901 Reset/reload occurred Determine if service action or tracking event
B181E902 No SRC in log Determine if service action or tracking event
B181E90a Unable to clear bits in the DISR Determine if service action or tracking event
B181E90d No routine for reset/reload call Determine if service action or tracking event
B181E90e Invalid routine for reset/reload call Determine if service action or tracking event
B181E90f Received unexpected signal Determine if service action or tracking event
B181E910 Unable to set bits in the DISR Determine if service action or tracking event
B181E911 Reset/reload occurred Determine if service action or tracking event
B181EA00 Unable to create a session entry object for the specified HMC index Determine if service action or tracking event
B181EA01 Error while packaging outbound payload data for the HMC Determine if service action or tracking event
B181EA02 Failure occurred with another component API Determine if service action or tracking event
B181EA03 Failed to read from or write to registry Determine if service action or tracking event
B181EA04 No Concurrent Maintenance lock found Determine if service action or tracking event
B181EA05 Unable to convert location code to RID Determine if service action or tracking event
B181EA06 Failure occurred with another component API Determine if service action or tracking event
B181EA07 Failure occurred with another component API Determine if service action or tracking event
B181EA08 Failure occurred with another component API Determine if service action or tracking event
B181EA09 Invalid RID for Concurrent Maintenance request Determine if service action or tracking event
B181EA0A Machine type or state incorrect for Concurrent Maintenance operations Determine if service action or tracking event
B181EA0B Node or GX resource failed during hot add Determine if service action or tracking event
B181EA0C Failure occurred with another component API Determine if service action or tracking event
B181EA0D Sequencing failure or cannot write checkpoint because system is transitioning Determine if service action or tracking event
B181EA0E Not enough memory to reserve a GX adapter Determine if service action or tracking event
B181EA0F Failed to read path from registry Determine if service action or tracking event
B181EA10 Detected corruption of the GX reservation area Determine if service action or tracking event
B181EA11 Failed to send activation asynchronization message Determine if service action or tracking event
B181EA12 Failed to create session entry object Determine if service action or tracking event
B181EA13 Unable to gard the FSP Determine if service action or tracking event
B181EA14 Failed to unlock file mutex Determine if service action or tracking event
B181EA15 FSP aborted the transition file Determine if service action or tracking event
B181EA16 Failed to send progress code Determine if service action or tracking event
B181EA17 Unable to read sibling FSP state data Determine if service action or tracking event
B181EA18 Failed to activate power domain Determine if service action or tracking event
B181EA19 Abort detected Determine if service action or tracking event
B181EA1A The system has new FSP cables attached to the system, but they are not the appropriate ones Determine if service action or tracking event
B181EA1E Concurrent Maintenance operation started Determine if service action or tracking event
B181EA1F Concurrent Maintenance operation stopped Determine if service action or tracking event
B181EF01 Only one active object is allowed per process Determine if service action or tracking event
B181EF02 Failed to detect error in normal path Determine if service action or tracking event
B181EF03 Check for valid FSP dump failure Determine if service action or tracking event
B181EF0A External failure writing registry Determine if service action or tracking event
B181EF0C Inconsistency in saved data header Determine if service action or tracking event
B181EF0D Failure reading or writing a file Determine if service action or tracking event
B181EF0F Notify PHYP failure Determine if service action or tracking event
B181EF11 Failed to update headers Determine if service action or tracking event
B181EF12 Failed to update headers Determine if service action or tracking event
B181EF13 Failed to update headers Determine if service action or tracking event
B181EF17 Failed to seek correct position in file Determine if service action or tracking event
B181EF1A Failed to display status to Panel Determine if service action or tracking event
B181EF1F Failed to enable FSP dump Determine if service action or tracking event
B181EF28 I/O controller error Determine if service action or tracking event
B181EF2D Failed to signal for HMC notification Determine if service action or tracking event
B181EF2E Internal HMC notify failure Determine if service action or tracking event
B181EF2F HMC notify failure Determine if service action or tracking event
B181EF32 Failed to initialize I/O controller Determine if service action or tracking event
B181EF33 Failed to close I/O controller Determine if service action or tracking event
B181EF34 Failed to check inputs Determine if service action or tracking event
B181EF35 Failed to check inputs Determine if service action or tracking event
B181EF36 Failed to setup for command Determine if service action or tracking event
B181EF37 Failed to setup for command Determine if service action or tracking event
B181EF38 Failed to trace command Determine if service action or tracking event
B181EF39 Failed to trace command Determine if service action or tracking event
B181EF3D Failed to display status to Panel Determine if service action or tracking event
B181EF3E Failed to read registry Determine if service action or tracking event
B181EF3F Failed to write registry Determine if service action or tracking event
B181EF40 Failed to trace command Determine if service action or tracking event
B181EF41 Failed to trace command Determine if service action or tracking event
B181EF42 NULL command specified Determine if service action or tracking event
B181EF44 Failed default command Determine if service action or tracking event
B181EF45 Failed to zip memory Determine if service action or tracking event
B181EF46 Failed to collect data Determine if service action or tracking event
B181EF4A Failed to read registry Determine if service action or tracking event
B181EF4B Failed to write registry Determine if service action or tracking event
B181EF4C Failed to complete headers Determine if service action or tracking event
B181EF4D Failed to complete dumped headers Determine if service action or tracking event
B181EF52 Invalid input for FSP dump Determine if service action or tracking event
B181EF53 No data to gather for FSP dump specified Determine if service action or tracking event
B181EF54 Not enough room left on flash Determine if service action or tracking event
B181EF55 Not enough room left on flash Determine if service action or tracking event
B181EF56 Moving backwards in the FSP dump file caused error Determine if service action or tracking event
B181EF57 Moving backwards in the FSP dump file caused error Determine if service action or tracking event
B181EF5A Failed to get FSP dump id Determine if service action or tracking event
B181EF5B Failed to get FSP dump length Determine if service action or tracking event
B181EF5C Failed to read registry Determine if service action or tracking event
B181EF5D Failed to read registry Determine if service action or tracking event
B181EF5E Failed to execute Panel function 20 Determine if service action or tracking event
B181EF5F Failed to read registry Determine if service action or tracking event
B181EF62 Failed to execute FSP dump Determine if service action or tracking event
B181EF63 Failed to execute FSP dump Determine if service action or tracking event
B181EF64 Failed to execute FSP dump Determine if service action or tracking event
B181EF65 Out of flash failure Determine if service action or tracking event
B181EF66 FSP dump controller failure acknowledged, must continue Determine if service action or tracking event
B181EF67 FSP dump controller failure acknowledged, terminate FSP dump sequence Determine if service action or tracking event
B181EF69 FSP dump controller failure Determine if service action or tracking event
B181EF6C Failed I/O boundary device Determine if service action or tracking event
B181EF6D Failed to write FSP dump Determine if service action or tracking event
B181EF71 Failed to check for valid FSP dump Determine if service action or tracking event
B181EF73 Failed to start FSP dump due to not finding FSP dump file Determine if service action or tracking event
B181EF75 Failed to start FSP dump due to not finding FSP dump file Determine if service action or tracking event
B181EF79 Failed to start FSP dump Determine if service action or tracking event
B181EF7A Failed to increment device bank Determine if service action or tracking event
B181EF7B Failed opening FSP dump device for initial navigation Determine if service action or tracking event
B181EF7C Failed to lock FSP dump device Determine if service action or tracking event
B181EF7D Failed to close FSP dump device Determine if service action or tracking event
B181EF7E Failed initial device navigation Determine if service action or tracking event
B181EF7F Failed to close device navigation Determine if service action or tracking event
B181EF80 Code updated forced clear of all pending and existing FSP dumps Determine if service action or tracking event
B181EF81 Failed FSP dump cancellation checking Determine if service action or tracking event
B181EF82 Cancelled dump due to Code update Determine if service action or tracking event
B181EF83 Failed to invalidate FSP dump Determine if service action or tracking event
B181EF84 Failed to retrieve FSP dump Determine if service action or tracking event
B181EF85 A FSP Dump occurred Determine if service action or tracking event
B181EF86 Failed to read registry Determine if service action or tracking event
B181EF87 Failed to set lid for FSP dump Determine if service action or tracking event
B181EF88 A user or surveillance initiated a FSP dump Determine if service action or tracking event
B181EF8B Failed to set header value Determine if service action or tracking event
B181EF8D Failed to check boot watchdog sideswitch Determine if service action or tracking event
B181EF8F Failed to get dynamic MTD sizing Determine if service action or tracking event
B181EF90 Failure in creating a buffer about a critical FSP dump operation Determine if service action or tracking event
B181EF91 FSP dump was invalidated Determine if service action or tracking event
B181EF93 Cannot enable degraded mode as FSP dump device is locked Determine if service action or tracking event
B181EF94 Temporarily disabled function due to code update Determine if service action or tracking event
B181EF95 Code update deallocated part of FSP dump data and user is trying to access them Determine if service action or tracking event
B181EF96 Can’t enable degraded mode because there are FSP dumps pending Determine if service action or tracking event
B181EF97 Degraded partition interface error Determine if service action or tracking event
B181EF98 Inconsistency in the persistent storage area in flash was detected Determine if service action or tracking event
B181EF99 Multiple FSP dump support logic failure Determine if service action or tracking event
B181EF9A Out of FSP dump storage Determine if service action or tracking event
B181EF9B Failed to open file Determine if service action or tracking event
B181EF9C Failed to read registry Determine if service action or tracking event
B181EF9D Confirm bank enablement failure Determine if service action or tracking event
B181EF9E Persistent storage area was reinitialized Determine if service action or tracking event
B181EF9F General failure during initialization of FSP dump Determine if service action or tracking event
B181F000 Failed to remove directory Determine if service action or tracking event
B181F003 Not able to create directory Determine if service action or tracking event
B181F004 Error return from file open command Determine if service action or tracking event
B181F005 Error return trying to read from a file Determine if service action or tracking event
B181F006 Error returned trying to write to a file Determine if service action or tracking event
B181F007 Failed to get status of file Determine if service action or tracking event
B181F009 Error returned trying to seek offset file Determine if service action or tracking event
B181F00E Error returned from a DMA Write attempt Determine if service action or tracking event
B181F00F Failed to get next file space Determine if service action or tracking event
B181F010 Illegal MDRT section size detected Determine if service action or tracking event
B181F012 Failed to determine size of registry variable Determine if service action or tracking event
B181F013 Error return trying to read from the registry Determine if service action or tracking event
B181F014 Error returned trying to write to the registry Determine if service action or tracking event
B181F015 Error returned from thread function Determine if service action or tracking event
B181F017 Error return from another function Determine if service action or tracking event
B181F018 Received an unexpected signal Determine if service action or tracking event
B181F019 Object not found or returned Determine if service action or tracking event
B181F01A The requested Policy value is not in the bounds Determine if service action or tracking event
B181F01B Unable to stop Clocks within the dump hardware collection Determine if service action or tracking event
B181F01C Control Block not valid size or invalid flattened control block Determine if service action or tracking event
B181F01E Status failure in call to create SRC object Determine if service action or tracking event
B181F022 No file spaces left to store dump memory on Determine if service action or tracking event
B181F029 System busy or there is no dump pending flag set Determine if service action or tracking event
B181F02C Override Content has change dump type to NO DUMP Determine if service action or tracking event
B181F02D A No Dump request was made Determine if service action or tracking event
B181F02E Manufacturing Policy Flag has set NO DUMP policy Determine if service action or tracking event
B181F02F No dump correctable error file present Determine if service action or tracking event
B181F030 Mainstore dump not taken Determine if service action or tracking event
B181F031 A correctable error was encountered while invalidating dump Determine if service action or tracking event
B181F038 Termination of the system to occur Determine if service action or tracking event
B181F039 Requested to invalidate the dump on the system Determine if service action or tracking event
B181F03B It was determined that no exit error state IPL would be needed because no mainstore dump is required Determine if service action or tracking event
B181F03C Mainstore dump not taken Determine if service action or tracking event
B181F03D Non-user requested dump and the dump policy is set to NO DUMP Determine if service action or tracking event
B181F03E Dump pending. Must invalidate dump before another dump can be called Determine if service action or tracking event
B181F100 Invalid position on chain Determine if service action or tracking event
B181F101 No chips in chain Determine if service action or tracking event
B181F102 Commands added exceed chain command size Determine if service action or tracking event
B181F104 Chip not found Determine if service action or tracking event
B181F105 Invalid Ring buffer size Determine if service action or tracking event
B181F10A Failure to release lock Determine if service action or tracking event
B181F110 Failure with controller device driver Determine if service action or tracking event
B181F111 Invalid device number Determine if service action or tracking event
B181F118 Abort signaled Determine if service action or tracking event
B181F11A Failure to release lock Determine if service action or tracking event
B181F11B Attempt to release lock that is not held Determine if service action or tracking event
B181F125 Invalid command ID Determine if service action or tracking event
B181F126 Invalid use of get scom JTAG interface Determine if service action or tracking event
B181F127 Invalid use of put scom JTAG interface Determine if service action or tracking event
B181F128 Invalid use of flush JTAG interface Determine if service action or tracking event
B181F12C Unmatched CRC Determine if service action or tracking event

If it is a service action, go to FSPSP45.

B181F12D Chip detected CRC miscompare on scan-in Determine if service action or tracking event
B181F12E Detected scom attentions Determine if service action or tracking event
B181F12F Bad parity or invalid command Determine if service action or tracking event
B181F130 Invalid flush operation code Determine if service action or tracking event
B181F131 Last bits of chip command status are not 0x01 Determine if service action or tracking event
B181F132 Invalid ring selection Determine if service action or tracking event
B181F133 Clocks did not start Determine if service action or tracking event
B181F134 Could not stop clocks Determine if service action or tracking event
B181F135 Invalid call to enable drivers Determine if service action or tracking event
B181F136 Invalid call to disable drivers Determine if service action or tracking event
B181F138 Scom attention detected on the current chip Determine if service action or tracking event
B181F139 Master Attention Alone detected Determine if service action or tracking event
B181F13A Unrecognized attention type condition Determine if service action or tracking event
B181F13B Invalid function call to attentions Determine if service action or tracking event
B181F13D Prohibited command found during initialize scom IPL step Determine if service action or tracking event
B181F13E Unable to find CEC cage Determine if service action or tracking event
B181F140 Data shows invalid ECID value Determine if service action or tracking event
B181F141 Indicates a potential problem with clock card Determine if service action or tracking event
B181F142 Could not get valid hom id of active clock card Determine if service action or tracking event
B181F200 Configuration failure Determine if service action or tracking event
B181F201 The HOM unit ID is not present in this system Determine if service action or tracking event
B181F202 The mainstore memory size has not been properly initialized Determine if service action or tracking event
B181F206 There is a card in the system that is missing or has corrupted VPD data Determine if service action or tracking event
B181F208 Avoid following the NULL rule facade pointer Determine if service action or tracking event
B181F209 The specified card object was not found Determine if service action or tracking event
B181F20A The call to create a card returned a NULL pointer Determine if service action or tracking event
B181F20B An error occurred while creating a system domain and returned a NULL pointer Determine if service action or tracking event
B181F20C There was an error while attempting to create a group and the function returned a NULL group pointer Determine if service action or tracking event
B181F20D There is an inconsistency between the size of the JTAG chain and the number of JTAG chains counted Determine if service action or tracking event
B181F20E The chip rule facade pointer created was returned as NULL Determine if service action or tracking event
B181F211 Creation of a cage pointer failed Determine if service action or tracking event
B181F212 The cage rule facade pointer was not found Determine if service action or tracking event
B181F217 An error occurred while attempting to create the JTAG controller object and returned a NULL instance pointer Determine if service action or tracking event
B181F21C The instance variable for the JTAG chains is NULL even after successful creation of the chains Determine if service action or tracking event
B181F21D The FRU was not found or does not exist Determine if service action or tracking event
B181F21E The MRU or FRU was not found or does not exist Determine if service action or tracking event
B181F21F Invalid input Determine if service action or tracking event
B181F220 The functional unit for a JTAG operation was not found Determine if service action or tracking event
B181F222 The functional unit has experienced a hardware monitor error Determine if service action or tracking event
B181F225 Attempting to write an invalid frequency to a clock card Determine if service action or tracking event
B181F227 An invalid VPD port number was encountered Determine if service action or tracking event
B181F228 A memory block trying to be referenced is out of range Determine if service action or tracking event
B181F229 The plug count for the MCM is not correct. Determine if service action or tracking event
B181F22A There was not enough functional hardware found in the system to continue IPLing Determine if service action or tracking event
B181F22B A memory controller group pointer was initialized to NULL by the cvMapper Determine if service action or tracking event
B181F22C Got an invalid unit id Determine if service action or tracking event
B181F239 Detected a missing chip Determine if service action or tracking event
B181F23E There is a mismatch between the number of nodes present and the type of SMP cable being used Determine if service action or tracking event
B181F23F The mainstore configuration changed from the previous IPL, mainstore cannot be preserved Determine if service action or tracking event
B181F241 Light strips have not been plugged correctly Determine if service action or tracking event
B181F242 The slot specified should NOT be turned on Determine if service action or tracking event
B181F243 PRS data returned indicates that the Light Strip attempting to be powered off was not powered off Determine if service action or tracking event
B181F244 It seems that both clock cards, which should be present in the system, are not present in the system Determine if service action or tracking event
B181F245 This is an unrecognized cable state for this machine Determine if service action or tracking event
B181F25E Cannot get a pointer to the System Fabric Group Determine if service action or tracking event
B181F2C0 Function pointer from dynamic load is NULL Determine if service action or tracking event
B181F2C1 Functional Unit of wrong type Determine if service action or tracking event
B181F2CC Invalid parameter passed in to function Determine if service action or tracking event
B181F2CD Failed trying to release JTAG Controller lock after reading the JTAG Controller's interrupt registers Determine if service action or tracking event
B181F2DC Received an empty list of Chips at attention Determine if service action or tracking event
B181F2DE Elastic Interface Alignment Procedure never completed Determine if service action or tracking event
B181F2DF Fatal IAP Error Determine if service action or tracking event
B181F2E0 Non-fatal IAP Error/Warning Determine if service action or tracking event
B181F2E3 Couldn't get pointer object Determine if service action or tracking event
B181F2E4 Selected elastic interface is Non-functional Determine if service action or tracking event
B181F2E5 One or more lines are stuck low for the ISR because the value read back does not match FF's Determine if service action or tracking event
B181F2E6 The attention line stuck high test failed to clear all the FSP attention lines Determine if service action or tracking event
B181F301 Object not initialized Determine if service action or tracking event
B181F304 Object attributes not set Determine if service action or tracking event
B181F305 Failed to set scom register attributes Determine if service action or tracking event
B181F306 Attributes are not set Determine if service action or tracking event
B181F308 Attributes not yet set Determine if service action or tracking event
B181F309 Could not find a Functional Unit that used the specified ring or register Determine if service action or tracking event
B181F30A Data not extracted Determine if service action or tracking event
B181F30B Data not inserted Determine if service action or tracking event
B181F30F Incorrect buffer size Determine if service action or tracking event
B181F310 Incorrect buffer size Determine if service action or tracking event
B181F311 Required register or ring not present Determine if service action or tracking event
B181F312 File open error Determine if service action or tracking event
B181F401 Illegally calling this function Determine if service action or tracking event
B181F405 Could not create cage rule facade for this cage Determine if service action or tracking event
B181F407 Could not find a unique or default entry for this combination of inputs Determine if service action or tracking eventDetermine if service action or tracking event

If it is a service action, go to FSPSP45.

B181F408 Could not read card slot table - end of file or file failure Determine if service action or tracking event
B181F409 End of file reached before row number found Determine if service action or tracking event
B181F40a Size of array needed exceeds size of array passed in Determine if service action or tracking event
B181F40b Number exceeded maximum number allowed Determine if service action or tracking event
B181F40c Could not open library for the object to create or unflatten Determine if service action or tracking event
B181F40d Could not open class for the object to create or unflatten Determine if service action or tracking event
B181F500 File IO error occurred Determine if service action or tracking event
B181F501 The specified HOM Object was not found Determine if service action or tracking event
B181F502 Specified HOM Object does not exist Determine if service action or tracking event
B181F504 The requested function is invalid Determine if service action or tracking event
B181F505 User attempted to save a HOM signature into a data buffer that was too small for the amount of data to be saved Determine if service action or tracking event
B181F506 Got an invalid unit id Determine if service action or tracking event
B181F507 A thread failed to start Determine if service action or tracking event
B181F620 Failure with functional unit Determine if service action or tracking event
B181F621 Scom bus busy after timeout Determine if service action or tracking event
B181F625 Timed out waiting for instructions to stop Determine if service action or tracking event
B181F62A Timeout reached on scom poll Determine if service action or tracking event
B181F62B Tried a clock operation which isn’t supported on this functional unit Determine if service action or tracking event
B181F62E Trying to instruction step while they are still running Determine if service action or tracking event
B181F630 I2C lock counter is a negative number, it should always be positive or zero Determine if service action or tracking event
B181F633 Failure while trying to open the attention handler data file for write operation Determine if service action or tracking event
B181F634 The bits active in the Special Attention register are not supported Determine if service action or tracking event
B181F636 Object pointer returned NULL Determine if service action or tracking event
B181F638 Clocks need to be on or off but mode says not to change state Determine if service action or tracking event
B181F639 Bad parameter passed into function Determine if service action or tracking event
B181F63B Instructions failed to start Determine if service action or tracking event
B181F63C Instructions failed to step Determine if service action or tracking event
B181F63D Unexpected NULL pointer for Fabric Functional unit Determine if service action or tracking event
B181F647 An attention is active from a thread which is not alive Determine if service action or tracking event
B181F648 Cannot process special attention since Memory controller object is null Determine if service action or tracking event
B181F649 XScom is busy or has errors Determine if service action or tracking event
B181F64A FOCR state machine wasn't idle after clearing Determine if service action or tracking event
B181F64B The GR GX auto TLAR calculation failed Determine if service action or tracking event
B181F64C Failed to complete self synchronization Determine if service action or tracking event
B181F64D Error encountered during self synchronization Determine if service action or tracking event
B181F64F Address + entries exceeds maximum SMA External SRAM size Determine if service action or tracking event
B181F653 Service buffer timed out while writing data Determine if service action or tracking event
B181F654 An attention not supported has been detected in SMA hardware Determine if service action or tracking event
B181F658 Invalid data Determine if service action or tracking event
B181F659 Not able to find master or slave target time data for a chip Determine if service action or tracking event
B181F65A GS Figtree database not loaded for this object or Functional Unit Determine if service action or tracking event
B181F65D Memory queues are not idle Determine if service action or tracking event
B181F65E Maintenance command timed out Determine if service action or tracking event
B181F65F Maintenance command failed Determine if service action or tracking event
B181F660 Command in progress while trying to send maintenance command Determine if service action or tracking event
B181F661 Instruction start or stop attempted on non alive thread Determine if service action or tracking event
B181F662 Fabric initialization failed on processor Determine if service action or tracking event
B181F663 Fabric initialization failed on processor Determine if service action or tracking event
B181F664 Fabric Quiesce failed Determine if service action or tracking event
B181F67B Got an invalid unit id or NULL pointer Determine if service action or tracking event
B181F67C Calling function on invalid object Determine if service action or tracking event
B181F67D Operation attempted on nonfunctional Functional unit Determine if service action or tracking event
B181F686 Can't get the associated FRU ID Determine if service action or tracking event
B181F689 Could not find associated Chip Determine if service action or tracking event
B181F68C Unsupported bit(s) set in the local special attention register Determine if service action or tracking event
B181F68D Fir bit indicates problem with SP code or SMI Determine if service action or tracking event
B181F6F2 Microcode failed to execute Determine if service action or tracking event
B181F6F3 Microcode failed to execute Determine if service action or tracking event
B181F6F6 Bootstrap executed successfully, but FSP was not permitted to set MP Available latch Determine if service action or tracking event
B181F7A0 The dump file contains a dump and cannot be read by the saved configuration for fast boot feature to examine the previous system configuration Determine if service action or tracking event
B181F7A1 Figtree library call failed Determine if service action or tracking event
B181F7A2 No TCE region found for GX Controller Determine if service action or tracking event
B181F7A7 No valid MC PLL Multiplier found when MC uses internal clock source Determine if service action or tracking event
B181F7A8 Host PCI enable failed Determine if service action or tracking event
B181F7A9 Host PCI verify failed Determine if service action or tracking event
B181F7AA No functional Processor clock card was found Determine if service action or tracking event
B181F7AB Memory Sharing Group is an invalid configuration Determine if service action or tracking event
B181F7AC A chip is in Bus Trace Mode, but doesn't have any attached memory Determine if service action or tracking event
B181F7AD Memory group contains chip in Bus Trace Mode, but base address is zero Determine if service action or tracking event
B181F7AE No system EI table found for bus Determine if service action or tracking event
B181F7AF No entry in system EI data table for bus and master chip position Determine if service action or tracking event
B181F7B8 Resource pointer was NULL Determine if service action or tracking event
B181F7B9 The passed in buffer pointer was NULL Determine if service action or tracking event
B181F7BA Couldn't find frequency data type requested Determine if service action or tracking event
B181F7BB The system resource(s) in the callout list failed a system configuration test Determine if service action or tracking event
B181F7BC The user specified LMB size is not valid for this system's memory size, so the system will use the default LMB size for this configuration Determine if service action or tracking event
B181F801 NULL Functional Unit Pointer Determine if service action or tracking event
B181F802 Not enough space Determine if service action or tracking event
B181F803 Not enough space Determine if service action or tracking event
B181F804 Index out of bounds Determine if service action or tracking event
B181F805 Failed to read the number of memory chips Determine if service action or tracking event
B181F806 Procedure error using display/alter Determine if service action or tracking event
B181F807 Invalid thread selected for FPSCR Determine if service action or tracking event
B181F809 Unable to associate array ID for address Determine if service action or tracking event
B181F80a Invalid operation specified Determine if service action or tracking event
B181F80b Unable to Create or remap Logical to Physical Mapper Determine if service action or tracking event
B181F80c Could not create server object instance Determine if service action or tracking event
B181F814 Invalid address. Does not map to any memory location Determine if service action or tracking event
B181F815 Invalid Data Length specified Determine if service action or tracking event
B181F816 NULL Rule Chip Facade Pointer Determine if service action or tracking event
B181F817 Error encountered while reading array entry Determine if service action or tracking event
B181F818 Error encountered while writing array entry Determine if service action or tracking event
B181F81b Mismatch data error Determine if service action or tracking event
B181F81e Unable to allocate buffer or NULL pointer detected Determine if service action or tracking event
B181F950 received an unexpected signal Determine if service action or tracking event
B181F951 Error from abort message Determine if service action or tracking event
B181F952 Buffer is NULL or is too small to hold information Determine if service action or tracking event
B181F953 Failed to receive message Determine if service action or tracking event
B181F954 Error creating serial thread in cec server Determine if service action or tracking event
B181F955 Error creating listener thread in cec server Determine if service action or tracking event
B181F956 Failed to get token in cec server Determine if service action or tracking event
B181F957 Invalid command received Determine if service action or tracking event
B181F958 Failure obtaining mutex lock in serial thread Determine if service action or tracking event
B181F959 Error while sending message Determine if service action or tracking event
B181F95A Error while sending message Determine if service action or tracking event
B181F95B Error receiving message in serial thread Determine if service action or tracking event
B181F95E Error initializing cec server daemon Determine if service action or tracking event
B181F95F Invalid arguments Determine if service action or tracking event
B181F966 Error while unflattening HOM data Determine if service action or tracking event
B181F968 Error writing to bit buffer Determine if service action or tracking event
B181F96A Not enough parameters Determine if service action or tracking event
B181F96B No function specified Determine if service action or tracking event
B181F96C Specified function not found Determine if service action or tracking event
B181F96D Too many parameters supplied Determine if service action or tracking event
B181F96E Unknown option specified Determine if service action or tracking event
B181F96F Some value required for these options is missing Determine if service action or tracking event
B181F970 Unknown parameter type Determine if service action or tracking event
B181F971 Input value out of range Determine if service action or tracking event
B181F972 Invalid input character Determine if service action or tracking event
B181F973 String not found in lookup table Determine if service action or tracking event
B181F974 Buffer too small Determine if service action or tracking event
B181F975 Unknown output type Determine if service action or tracking event
B181F978 An HMC requested operation is not supported Determine if service action or tracking event
B181FAA3 Invalid parameter to function Determine if service action or tracking event
B181FAA4 Number of packets sent does not equal number received or CRC not zero Determine if service action or tracking event
B181FAA9 Can't get the sharing group for this Chip Determine if service action or tracking event
B181FAB0 Physical Status registers not set to link up; test can not proceed Determine if service action or tracking event
B181FAB1 Number of packets sent does not equal number received or CRC not zero Determine if service action or tracking event
B181FAB2 RIO test failure Determine if service action or tracking event
B181FAB3 Galaxy test failed during communication stage Determine if service action or tracking event
B181FB51 Maximum number of wire test errors has been reached Determine if service action or tracking event
B181FB54 RDT has detected a hardware error Determine if service action or tracking event
B181FD00 An FSP or DMA path was GARDed out Determine if service action or tracking event
B181FD01 The command line was used to manually configure or deconfigure a resource Determine if service action or tracking event
B181FD02 GARD Data did not exist because either it was the first IPL on this machine or NVRAM had been cleared Determine if service action or tracking event
B181FD03 GARD detected a new version of the gard data area Determine if service action or tracking event
B181FD04 GARD detected corrupt gard date Determine if service action or tracking event
B181FD05 GARD could not open the Gard Memory File Determine if service action or tracking event
B181FD06 Error trying to read a file Determine if service action or tracking event
B181FD07 Error trying to write IO Data to the Gard file Determine if service action or tracking event
B181FD0A Failed setting the rank status in the HOM Determine if service action or tracking event
B181FD0B Failed setting functional status of a non-rank unit Determine if service action or tracking event
B181FD0D Failed to read registry Determine if service action or tracking event
B181FD0E Failed to read the VPD data for a given resource id Determine if service action or tracking event
B181FD10 The input Resource ID is not an FSP that can have its GARD state changed Determine if service action or tracking event
B181FD11 Manual deconfiguration of FSP is not allowed because FSP is already System Deconfigured or because we are at runtime Determine if service action or tracking event
B181FD12 This interface was called with more than the allowed number of DMA Paths Determine if service action or tracking event
B181FD13 The input DMA path did not match any stored in VPD Determine if service action or tracking event
B181FD14 Ungarding the sibling FSP is not allowed at Runtime Determine if service action or tracking event
B1828811 Incorrect command in Attention Area memory as it does not match up with the requested Service Routine Determine if service action or tracking event
B182901C Failed trying to get status of the LID file Determine if service action or tracking event
B182901D Failed to get OLC or CONTINUE ACK response from PHYP Determine if service action or tracking event
B182901F SPIRA does not have sufficient space for the data structure Determine if service action or tracking event
B1829025 Event id which satisfied the monitor was incorrect Determine if service action or tracking event
B1829503 The FSP has queued its maximum number of messages to the send queue Determine if service action or tracking event
B1829504 There is nobody waiting on the message we just received from PHYP Determine if service action or tracking event
B1829507 Unable to write error\event log that PHYP wanted Determine if service action or tracking event
B1829508 PHYP passed the FSP a zero TCE or a TCE with something in the top 4 bytes Determine if service action or tracking event
B182950C Indicates that PHYP sent the FSP a bad size, modifier or HMC index Determine if service action or tracking event
B182950D PHYP didn't provide enough data to write the LID or the first TCE is too small to contain the LID header (although the latter is less likely) Determine if service action or tracking event
B1829511 Warning that HMC message has reached timeout limit Determine if service action or tracking event
B1829512 PHYP tried adding an existing HMC buffer to the list Determine if service action or tracking event
B1829513 PHYP is garding the anchor card and since we don't get any SRC from them, we make this one up Determine if service action or tracking event
B182951A Wrong modifier received on OLC command Determine if service action or tracking event
B182951C PHYP didn't acknowledge the message that the FSP sent to it within the architected timeout value Determine if service action or tracking event
B182951D PHYP tried to use a HMC buffer that they haven't defined or they don't own Determine if service action or tracking event
B182951E PHYP returned non-zero status in the acknowledge message Determine if service action or tracking event
B1829523 Failed on setup for reset/reload Determine if service action or tracking event
B182D004 Failed to get enclosure list Determine if service action or tracking event
B182D005 Failed to set drawer information Determine if service action or tracking event
B182E500 Bad hardware Determine if service action or tracking event
B182F023 Bad TCE returned Determine if service action or tracking event
B1878707 Error function not available Determine if service action or tracking event
B187E500 Bad hardware Determine if service action or tracking event
B1A3E500 Bad hardware Determine if service action or tracking event

Table 3. (B1xx) Service processor reason codes' ranges

Reason codes for Range Description
End Device Abstraction Layer (EDAL) ranges
DMA EDAL '1000'x through '10FF'x The direct memory access EDAL component (DMAE ) is a shared library that allow applications to transfer data between system memory and the service processor's address space.

DMAE is normally used by the Hypervisor™ data initialization (HDAT) component during boot. The dump component also uses DMAE for collecting dumps.

Control Panel I2C EDAL '1100'x through '111F'x IPNL provides an interface to the control panel hardware and handles all of the internal communication details. The PANL component uses IPNL extensively.
VPD I2C EDAL '1300'x through '13FF'x IVPD collects and reports vital product data (VPD) found in the system unit hardware. Data collected from the hardware is analyzed and stored file system of the service processor. Hardware VPD update facilities are also provided. VPD collection and reporting provides a system-wide view of the current hardware configuration.
RPC I2C EDAL '1400'x through '141F'x IRPC manages the low-level IIC bus interface to remote power controllers (RPCs) on some types of servers.
Smart Chip VPD EDAL '1500'x through '15AF'x SCED collects and reports VPD found in the system unit hardware. Data collected from the hardware is analyzed and stored in the file system of the service processor. Hardware VPD update facilities are also provided. VPD collection and reporting provides a system-wide view of the current hardware configuration.
Power control code ranges
Power Control Interface '2000'x through '204F'x The system power interface (SPIF) component provides a communication interface between service processor components and the system power control network (SPCN). The server uses SPIF to obtain the system power state and other data.
Remote Power Control '2100'x through '211F'x REMP manages the high-level communication protocol between the service processor and the RPCs on some types of servers.
IPL Lock '2200'x through '222F'x The IPL lock component synchronizes dependent operations with boot transition requests. It performs this synchronization by evaluating the system when a boot is requested.
Note: A dependent operation is an operation that requires that no boot transition request of a certain type be allowed while the operation is being performed. Writing to flash memory is an example of a dependent operation.
Auto Power On Restart '2300'x through '231F'x This component's functionality is configured by the customer. If enabled, this component automatically performs a power-on reboot following an unexpected loss of power.
Remote Platform Power On '2400'x through '241F'x The remote platform power on component allows a user to remotely power on a system using the wake on LAN capability (which is accessed via the ASMI) when the system is powered off.
Thermal Management '2600'x through '261F'x The thermal management component is responsible for reading processor thermal calibration data, for providing an interface which firmware uses to read processor temperatures, and for handling thermal alerts generated by the processor's thermal sensors.
System infrastructure ranges
Code Update '3000'x through '305F'x CUPD controls the updating of firmware on the service processor.

You might see this code when the error occurs:

  • During the code update (flash) process.
  • During the code promotion process. After the code updates successfully and the system reboots from the new code side, a user might use the code promote command to copy the new code from the temporary (or T side) to the permanent (or P) side.
  • When the service processor reboots after a code update, which is when the service processor makes the redundant boot code.
  • During the booting of the managed system, which is when the code update process attempts to verify flash image during the power on process for the system unit.

The error can be caused by:

  • A bad or invalid system firmware image
  • A service processor failure, which leads to the firmware being unable to perform the code update
  • Corruption of the update file, which occurs when the file is sent from the Hardware Management ConsoleHardware Management Console (HMCHMC) or the Hypervisor
  • An internal code problem
  • A problem with the network issue
  • A user error. which might occur when a user does not follow the update process
Discovery '3500'x through '35FF'x The DSCV component manages dual service processors in those systems that can have a primary and a secondary service processor. DSCV exchanges the required information between the service processors to establish the various communication links between them.
IPL Parameters '4000'x through '402F'x The IPLP component manages some of the service processor registry data that is transferred to the Hypervisor at boot time, such as IPL speed, logical memory block size, and so on.
RTC Application '5000'x through '503F'x The RTIM component manages the battery-backed real time clock hardware on the service processor, which is the source of the system-level time-of-day (TOD) clock.
State Manager '6000'x through '603F'x The SMGR component is responsible for supervising the IPL. It determines the validity of an IPL request and attempts to IPL the system.
State Transition Manager '6500'x through '651F'x The STTR component contains the various transition files that the system uses to make the transition from one state to another (for example, powering on or powering off the system unit, performing a platform dump, and so on).
Error Logging '7000'x through '703F'x The ERRL component provides data logging, entry management, and the reporting of application errors to the operating system.
Primary PCI bus Initialization '7100'x through '711F'x The PPIN component monitors for power events, such as power on and power off.
Boot Plug-in '7200'x through '721F'x The BOOT component reads user preferences and determines which service processor flash side to boot from.
Service processor firmware utilities ranges
Switch BCU utility '8100'x through '811F'x The SBCU component manages the PCI bus switch state in the registry.
Note: Two switch states are possible:
  • The service processor owns the PCI bus
  • The system unit owns the PCI bus
SRC Interface '8200'x through '821F'x The SRCI component is a service processor utility that allows the user to do the following:
  • Create, display, and trace SRCs
  • Retrieve SRC entries from an SRC trace
CEC Termination '8300'x through '834F'x The CTRM (CEC Termination) component terminates the service processor. When an application encounters a fatal error (that the application determines should lead to system termination), the application uses its error log to call CTRM. After being called, CTRM displays the terminating SRC on the panel and records the error.
NVRAM Initialization '8400'x through '841F'x The NVRI component used to initialize and configure the service processor.
Event Notification '8500'x through '853F'x The EVEN component provides the facilities to signal and monitor for the occurrence of specified events. It is one way of performing interprocess communication within the service processor firmware.
Process Error Context '8600'x through '861F'x The PERC component allows a service processor application to collect some flight recorder information (FFDC) when the service processor receives an unexpected signal.
Network Server '8700'x through '877F'x The NETS code component dynamically loads libraries for the operations and functions that it services.
Network Client '8780'x through '87FF'x The NETC component is the client interface plug-in that applications running on the service processor, manufacturing and the HMCHMC use to talk to the servers and other applications running on the service processors. NETC provides wrappers for the TCP/IP and sockets API and serial traffic APIs. It also provides a common message format for communication and data packets.
Hypervisor Service Routine '8800'x through '883F'x The HYSR component allows the user to run a Hypervisor service routine from the service processor. Typical uses of a Hypervisor service routine include validating a system storage address and performing a system storage dump for a platform dump.
Process Synchronization '8900'x through '891F'x The SINK component synchronizes the time when a server process is ready to interact with a client process.
Utility Component '8A00'x through '8A1F'x The UTIL component provides common functionality throughout the service processor environment, such as common file, registry, and semaphore manipulation.
External firmware interfaces ranges
Hypervisor Data Initialization '9000'x through '904F'x The HDAT component does the following:
  • Loads the Hypervisor code into system storage
  • Gathers various pieces of information that describe the hardware configuration and various boot parameters and loads that data into the main storage
  • Starts the execution of the processors that run the Hypervisor and the partition firmware
Host Virtual Serial Interface '9200'x through '921F'x The HVSI component provides the host virtual serial interface, which allows the host operating system to use the serial ports of the service processor as if they were the native serial ports.
Mailbox Handling '9500'x through '952F'x The MBOX component handles certain hardware on the service processor (called the mailbox) that is accessible to both the operating system and the service processor. The mailbox enables the system to transfer small amounts of data between the service processor and operating system, so that they can communicate to each other at runtime.
Service Processor Capacity Upgrade on Demand '9900'x through '991F'x The SCOD component provides information about the state of the previous power off and whether the system lost AC power after the power off.
Panel 'A000'x through 'A07F'x The PANL component processes the pressing of control panel buttons and updates the control panel display appropriately.
Virtual Panel 'A200'x through 'A21F'x The VPNL component implements the virtual control panel functions in the firmware.
Vital Product Data (VPD) 'B000'x through 'B0FF'x The SVPD component collects and reports VPD found in the hardware of the system unit, which provides a system-wide view of the current hardware configuration. Data collected from the hardware is analyzed and stored in file system of the service processor. SVPD also provides hardware VPD update facilities.
VPD Location Codes 'B100'x through 'B11F'x The VLOC component builds the location code table that the Hypervisor uses.
VPD LED Access 'B200'x through 'B21F'x The VLED component provides library routines to drive the LEDs of the system unit. VLED uses the SVPD component to provide the bus mapping information. Other components can use the VLED routines to drive the LEDs to the desired state.
HMCHMC Interface 'C000'x through 'C03F'x The HMCX component provides the communications interface between the HMCHMC and the service processor of the managed system.
Power Management 'C100'x through 'C1FF'x The POWR component controls the power supplies, regulators and blowers and collects and reports power status, power VPD, and temperatures of the system unit and I/O towers and drawers.
Service Processor Menus 'D000'x through 'D03F'x The MENU component provides both a Web browser interface and a legacy TTY (text based) interface (both are known as the Advanced System Management Interface, or ASMI). The ASMI enables users to configure the service processor, change selected system-level settings, and access certain service processor resources.
Attention Handler 'D100'x through 'D13F'x The ATTN component processes the checkstops, recovered errors, and special attentions that come from the hardware. ATTN also makes appropriate calls to components like processor runtime diagnostics (PRD) so that the system properly handles attentions.
Reliability, Availability, and Serviceability (RAS) ranges
Call-in/Call-out 'E000'x through 'E02F'x The CALL component provides remote service functions (like call home, call in, and call out) and SRC display on serial ports.
Snoop/Wrap 'E100'x through 'E11F'x The SNOP component provides the serial port snoop function. SNOP can be used only when the system is in single partition mode. This component also detects the legacy iSeries™ UPS, if present, and reports the number of serial ports available to the operating system.
CEC Reboot 'E200'x through 'E21F'x The RBOT component determines if an system unit re-IPL needs to occur after a termination.
LED Management 'E300'x through 'E31F'x The LEDS component supports the service indicators (used by to identify failing FRUs) and controls the system attention indicator.
Surveillance 'E400'x through 'E460'x The SURV component detects the failures of critical components, such as the Hypervisor or the HMCHMC, and takes the appropriate actions.
Processor Runtime Diagnostics 'E500'x through 'E51F'x When the service processor receives an attention from system hardware, PRDF examines the error registers in the system to determine what happened and creates an error log entry that calls out one or more failing items.
Note: The E500 code denotes a hardware error, or an error in software other than processor runtime diagnostics. The E501 code is reserved for PRD code errors.
Redundancy Manager 'E600'x through 'E6A0'x The RMGR component controls the interactions between the primary and the secondary service processors on a model 550, 590, or 595 system.
Synchronization of Redundant Service Processors 'E700'x through 'E71F'x The SYNC component, which is part of the RMGR component, performs data synchronization between the primary and the secondary service processors on a model 550, 590, or 595 system.
SMA Dump 'E800'x through 'E81F'x The SDMP component controls the sequencing of the initialization of SMA adapters to the message passing available state.
Reset/Reload 'E900'x through 'E91F'x The RSRL component saves the most recent critical error log in the event of a reset or reload event (on the assumption that this log best explains the reason for the reset). In cases where the reset or reload event terminates the system, RSRL sends its error log to the administrator.
Concurrent Maintenance 'EA00'x through 'EA1F'x The CCMM component provides the interface between the concurrent maintenance program (which is part of Service Focal Point) on the HMCHMC and the service processor of the managed system .
Service Processor Dump (Belly-up DuMP) 'EF00'x through 'EFCF'x The BDMP component dumps data that the system can use to debug a failure that occurs when the service processor and bulk power subsystems encounter an error on servers that are housed in 24-inch racks. The following service processor or bulk power subsystem errors might cause this type of dump:
  • An application failure that leads to a core dump
  • A panic of the service processor kernel
  • An unexpected reset of the service processor or bulk power subsystem
  • A user-injected dump on the service processor or bulk power subsystem that captures the state of the entire subsystem at a given moment in time
Dump 'F000'x through 'F03F'x After the system detects a checkstop or other hardware error condition, the DUMP component gathers required hardware and possibly system memory contents to facilitate error recreation and analysis.
Hardware Object Model (HOM) ranges
HOM JTAG Interface 'F100'x through 'F16F'x The HJTG component provides an interface for scanning data from firmware into the actual chips or from the chips into the firmware. The JtagInterface object represents the physical JTAG interface that is internal to each hardware chip. Firmware uses this piece of chip logic to communicate with the chip, and it is used anytime a JTAG operation is performed.
HOM Packaging Units 'F200'x through 'F25F'x The HPKU component is a package management class that holds and manages the system hardware object model.
HOM Groups 'F2C0'x through 'F2FF'x The HFUG component provides procedural support for chip functionality.
HOM Scan Rings 'F300'x through 'F31F'x The HREG (HOM register) component provides a firmware object that represents a scan ring, SCOM register, or an alias, with its unique characteristics (address, length, etc.) in order to scan chips. HREG also provides the data storage area (called a bit buffer) that holds the data to be scanned as well as the algorithms the system uses to manipulate the data stored in the buffer.
HOM Rules 'F400'x through 'F41F'x The RULE component provides access to certain configuration and engineering data that is stored in the esw_rtbl component. The system uses the data stored in the edw_rtbl component to model the system and to read from the hardware.
HOM Rules Tables 'F450'x through 'F46F'x The RTBL component holds data.
HOM Utilities 'F500'x through 'F51F'x The HUTL component provides common utility functions used by all of the hardware access code. HUTL also handles error logging and recovery actions for the system unit hardware during booting and execution of high-level boot steps related to initializing the system unit.
HOM Functional Units 'F620'x through 'F6FF'x The HFUS component provides internal access to the chip functionality.
Central Electronics Complex (CEC) ranges
CEC Chip Initialization 'F700'x through 'F7FF'x The CINI component initializes the chips in the system unit, based on the system configuration. These actions include configuring system memory and address ranges, chip modes, and communicating from chip to chip. CINI also determines and sets the processor and bus frequencies.
Display/Alter 'F800'x through 'F81F'x The DADA component accesses (reads) and manipulates (writes) user information inside the system unit hardware by using the JTAG interfaces. Several hardware components use this functionality, including the certain CPU chips, L3 cache devices, and I/O controllers.
Hardware Interface Commands 'F950'x through 'F98F'x The CHIC component provides the mechanism that allows a call made in an external service processor application to execute inside the system unit server application.
Automated Built-in Self-Test (ABIST) 'FA00'x through 'FA1F'x The ABST component runs internal chip diagnostics as part of the system boot process. ABST tests the logic and arrays in each chip (as applicable) and peforms array repair (bit sparing) for processor chips, if necessary.
Logic Built-in Self-Test (LBIST) 'FA50'x through 'FA6F'x The LBST component runs internal chip diagnostics as part of the system IPL process. LBST tests the logic and arrays in each chip (as applicable) and performs array repair (bit sparing) for processor chips, if necessary.
Memory Diagnostics 'FAA0'x through 'FABF'x The MDIA component performs diagnostics on the system memory and L3 cache during the boot process by writing patterns into and reading the patterns back from system storage and L3 cache.
SIBATS 'FB00'x through 'FB1F'x The SBAT component is part of the LBIST component.
Wiretest 'FB50'x through 'FB6F'x The WIRE component, a diagnostic routine used when the system is booted in slow mode, verifies the continuity and independence of interconnections in the system unit. WIRE checks for open and short circuits on the testable nets between chips.
Ring API (CEC Utility) 'FC00'x through 'FC1F'x The RAPI component does not display reason codes.
Resource Guard 'FD00'x through 'FD1F'x The GARD component provides the repeat GARD functionality for all "gardable" items (memory and processors) that are deconfigured and then marked "garded out" either at IPL or runtime. GARD also provides system configuration information to the menu system about system configuration.