PCIe adapter placement rules and slot priorities for the EMX0 PCIe Gen3 I/O expansion drawer

Find information about the placement rules and slot priorities for the Peripheral Component Interconnect (PCI) Express (PCIe) adapters that are supported for the EMX0 PCIe Gen3 I/O expansion drawer (EMX0 PCIe3 expansion drawer).

PCIe slot descriptions for the EMX0 PCIe3 expansion drawer

The number of PCIe slots that are provided in the EMX0 PCIe3 expansion drawer depends on the I/O module configuration of the EMX0 PCIe3 expansion drawer. Your configuration might have one or two PCIe3 6-slot fanout modules (FC EMXF or ELMF) installed in the rear of the EMX0 PCIe3 expansion drawer. Each PCIe3 6-slot fanout module provides six full-length, regular-height, PCIe generation 3 slots. The PCIe3 slots are compatible with generation 2 or generation 1 PCIe adapters. The PCIe slots use generation 3, single-wide, blind-swap cassettes.

The I/O module in the EMX0 PCIe3 expansion drawer is connected to the system with an expansion drawer cable pair. Each cable pair must be the same length and are attached to the T1 and T2 ports in the I/O module and to the corresponding ports in the PCIe3 cable adapter in the system.

Figure 1 shows the rear view of the EMX0 PCIe3 expansion drawer with the location codes for the PCIe adapter slots in the PCIe3 6-slot fanout module.

Table 1 lists the PCIe adapter slot locations and details for the EMX0 PCIe3 expansion drawer.
Figure 1. Rear view of a EMX0 PCIe3 expansion drawer with PCIe slot location codes
Note:
  • The left I/O module bay (as viewed from the rear) is configured with the first PCIe3 6-slot fanout module slot location codes P1-C1 through P1-C6.
  • The right I/O module bay (as viewed from the rear) is configured with the second PCIe3 6-slot fanout module slot location codes P2-C1 through P2-C6.
Rear view of a EMX0 PCIe3 expansion drawer with PCIe slot location codes.
Table 1. PCIe slot locations and descriptions for the EMX0 PCIe3 expansion drawer
Slot Location code (Slot label) Description Slot capabilities
SR-IOV Dynamic direct memory access (DMA) window I/O Adapter Enlarged Capacity assignment order
Slot 1 P1-C1 PCIe3 x16 Yes Yes Yes3
Slot 2 P1-C2 PCIe3 x8 No Yes2 No
Slot 3 P1-C3 PCIe3 x8 No No No
Slot 4 P1-C4 PCIe3 x16 Yes1 Yes2 No
Slot 5 P1-C5 PCIe3 x8 No Yes2 No
Slot 6 P1-C6 PCIe3 x8 No No No
Slot 7 P2-C1 PCIe3 x16 Yes Yes Yes3
Slot 8 P2-C2 PCIe3 x8 No Yes2 No
Slot 9 P2-C3 PCIe3 x8 No No No
Slot 10 P2-C4 PCIe3 x16 Yes1 Yes2 No
Slot 11 P2-C5 PCIe3 x8 No Yes2 No
Slot 12 P2-C6 PCIe3 x8 No No No

1The SR-IOV capability varies in slots P1-C4 and P2-C4 based on the amount of system memory. If the EMX0 PCIe3 expansion drawer is connected to a system with a total amount of physical memory greater than or equal to 128 GB, slots P1-C4 and P2-C4 are SR-IOV capable.

2The Dynamic direct memory access (DMA) window capability varies based on the amount of system memory. If the EMX0 PCIe3 expansion drawer is connected to a system with a total amount of physical memory greater than or equal to 64 GB, the slot is Dynamic direct memory access (DMA) window capable. If the total amount of physical memory is less than 64 GB, the slot is not Dynamic direct memory access (DMA) window capable.

3Slots P1-C1 and P2-C1 inherit the I/O Adapter Enlarged Capacity attribute from the slot in the system that connects to the EMX0 PCIe3 expansion drawer.

Notes:
  • All slots are PCIe generation 3 slots.
  • All slots support full-length, regular-height adapters or short form-factor with a regular-height tailstock in single-wide, generation 3, blind-swap cassettes.
  • Slots C1 and C4 in each PCIe3 6-slot fanout module are x16 PCIe3 buses and slots C2, C3, C5, and C6 are x8 PCIe buses.
  • All slots support enhanced error handling (EEH).
  • All PCIe slots are hot swappable and support concurrent maintenance.

PCIe adapters placement rules

Use this information while selecting slots for installing PCIe adapters in the EMX0 PCIe3 expansion drawer attached to the system. Use Table 2 to identify slot placement priorities and the maximum number of adapters that can be installed in the EMX0 PCIe3 expansion drawer based on the operating system.
Note: You can click the link that appears in the feature code column for more technical information specific to the PCIe adapter.
  1. If the EMX0 PCIe3 expansion drawer is configured with two PCIe3 6-slot fanout modules, distribute the PCIe adapters across both I/O modules whenever possible.
  2. If FC EC46 is driving the internal DVD, it must be installed in the IO expansion drawer that is closest to the system. The system and IO expansion drawer must be in the same rack.
    Note: If slot P1-C2 of the first node contains a controller adapter (CC), it must be the first option to consider for wiring the module (FanOut or DirectSlot) with the USB adapter driving the internal DVD. If it is a FanOut module, install FC EC46 in slot Px-C3 of the FanOut module.
  3. Do not attempt to install x16 adapters in x8 slots. Doing so can damage the x16 connectors in the EMX0 PCIe3 expansion drawer.

Verify whether the adapter is supported for your system. For details about PCIe adapter placement rules and slot priorities, see PCIe adapter placement.

Table 2. PCIe adapter slot priorities and maximum adapters supported in the EMX0 PCIe3 expansion drawer
Feature code Description EMX0 PCIe3 expansion drawer
Slot priorities1 Maximum number of adapters supported2
AIX® Linux IBM® i
2893 and 2894 PCI Express 2-Line WAN with Modem (FC 2893 and FC 2894; CCIN 576C); Adapter FRU number: 44V5323 6, 12 0 1 1
5285 PCIe2 2-port 4X InfiniBand QDR Adapter (FC 5285; CCIN 58E2); Adapter FRU number: 74Y2987 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
5287 PCIe2 2-port 10 GbE SR Adapter (FC 5287; CCIN 5287); Adapter FRU number: 74Y3457 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
5708 PCIe 10 Gb FCoE 2-port Adapter (FC 5708; CCIN 2B3B) 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
5717 4-port 10/100/1000 Base-TX PCI Express Adapter (FC 5717; CCIN 5217); Adapter FRU number: 46Y3512 2, 8, 3, 9, 5, 11, 6, 12, 1, 7, 4, 10 6 6 0
5729 PCIe2 FH 4-port 8 Gb74Y3467 Fibre Channel Adapter (FC 5729; CCIN 5729); Adapter FRU number: 74Y3467 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
5735 8 Gb PCI Express Dual-port Fibre Channel Adapter (FC 5735; CCIN 577D); Adapter FRU number: 10N9824 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 6
5744 PCIe2 2x10 GbE SR 2x1 GbE UTP Adapter (FC 5744; CCIN 2B44); Adapter FRU number: 74Y1987 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 6
5767 2-port 10/100/1000 Base-TX Ethernet PCI Express Adapter (FC 5767; CCIN 5767); Adapter FRU number: 46K6601 2, 8, 3, 9, 5, 11, 6, 12, 1, 7, 4, 10 6 6 6
5768 8 Gb PCI Express Dual-port Fibre Channel Adapter (FC 5735; CCIN 577D); Adapter FRU number: 10N9824 2, 8, 3, 9, 5, 11, 6, 12, 1, 7, 4, 10 6 6 6
5769 10 Gb Ethernet-SR PCI Express Adapter (FC 5769; CCIN 5769); Adapter FRU number: 46K7897 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
5772 10 Gb Ethernet-LR PCI Express Adapter (FC 5772; CCIN 576E); Adapter FRU number: 10N9034 2, 8, 5, 11, 3, 9, 6, 12, 1, 7, 4, 10 6 6 0
5774 4 Gb PCI Express Dual-port Fibre Channel Adapter (FC 5774; CCIN 5774); Adapter FRU number: 10N7255 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 6
5785 4-port Async EIA-232 PCIe Adapter (FC 5785; CCIN 57D2); Adapter FRU number: 46K6734 6, 12 1 1 0
5805 PCIe 380 MB Cache Dual - x4 3 Gb SAS RAID Adapter (FC 5805; CCIN 574E); Adapter FRU number: 46K4735 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
5899 PCIe2 4-port 1 GbE Adapter (FC 5899; CCIN 576F); Adapter FRU number: 74Y4064 2, 8, 3, 9, 5, 11, 6, 12, 1, 7, 4, 10 6 6 6
5901 PCIe Dual - x4 SAS Adapter (FC 5901; CCIN 57B3); Adapter FRU number: 44V4852 2, 8, 5, 11, 3, 9, 6, 12, 1, 7, 4, 10 6 6 6
5913 PCIe2 1.8 GB Cache RAID SAS Tri-port 6 Gb Adapter (FC 5913; CCIN 57B5); Adapter FRU number: 00J0596 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 6
EC28 PCIe2 2-port 10 GbE RoCE SFP+ adapter (FC EC28; CCIN EC27); Adapter FRU number: 000E1491 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
EC2J PCIe 2-Port 10 GbE SFN6122F Adapter (FC EC2J; CCIN EC2G); Adapter FRU number: 00E8224 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 0 6 0
EC2N PCIe3 2-port 10 GbE NIC and RoCE SR adapter (FC EC2N; CCIN 57BE); Adapter FRU number: 00RX875 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
EC30 PCIe2 FH 2-port 10 GbE RoCE SR adapter (FC EC30; CCIN EC29); Adapter FRU number: 00E1601 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
EC38 PCIe3 2-port 10 GbE NIC and RoCE SFP+ Copper Adapter (FC EC38; CCIN 57BC); Adapter FRU number: 00RX859 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
EC3B PCIe3 2-Port 40 GbE NIC RoCE QSFP+ Adapter (FC EC3B; CCIN 57BD); Adapter FRU number: 00FW105 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
EC46 PCIe2 4-port USB 3.0 Adapter (FC EC46; CCIN 58F9); Adapter FRU number: 00E2932 2, 8, 5, 11, 3, 9, 6, 12, 1, 7, 4, 10 6 6 6
EJ0J PCIe3 RAID SAS quad-port 6 Gb Adapter (FC EJ0J; CCIN 57B4); Adapter FRU number: 000FX846 1, 7, 4, 10, 3, 9, 6, 12 4 4 4
EJ0L PCIe3 12 GB Cache RAID SAS quad-port 6 Gb Adapter (FC EJ0L; CCIN 57CE); Adapter FRU number: 00FX840 1, 7, 4, 10, 3, 9, 6, 12 4 4 4
EJ10 PCIe3 4 x8 SAS Port Adapter (FC EJ10; CCIN 57B4); Adapter FRU number: 00RR793 for 8408-44E or 8408-E8E and 00MH959 for all other machine type models 1, 7, 4, 10, 3, 9, 6, 12 4 4 4
EJ14 PCIe3 12 GB Cache RAID PLUS SAS Adapter Quad-port 6 Gb x8 (FC EJ14; CCIN 57B1); Adapter FRU number 01DH742 1, 7, 4, 10, 3, 9, 6, 12 4 4 4
EJ1P PCIe1 SAS Tape/DVD Dual-port 3 Gb x8 Adapter (FC EJ1P and EJ1N; CCIN 57B3); Adapter FRU:44V4852 2, 5, 3, 6, 1, 4 6 6 6
EJ27, EJ28, and EJ29 PCIe Cryptographic Coprocessor (FC EJ27, FC EJ28, and FC EJ29; CCIN 476A); Adapter FRU number: 45D7948 2, 8, 5, 11, 3, 9, 6, 12, 1, 7, 4, 10 6 0 6
EJ33
4767-001 Cryptographic Coprocessor (FC EJ32 and EJ33; CCIN 4767)
  • PCIe1 x4
  • Half-length, with full-height tailstock (Dual Card)
  • Error Checking and Correction (ECC) Protection on DDR3 Memory
  • Over 300 Cryptographic algorithms and modes
  • OS support: AIX, IBM i, and Linux operating systems
2, 5, 3, 6, 1, 4 6 6 6
EL4L PCIe2 4-port 1 GbE Adapter (FC EL4L and EL4M; CCIN 576F); Adapter FRU number: 74Y4064 2, 8, 3, 9, 5, 11, 6, 12, 1, 7, 4, 10 6 6 6
EL53 PCIe3 2-port 10 GbE NIC and RoCE SFP+ Copper Adapter (FC EL53; CCIN 57BC); Adapter FRU number: 00RX859; Low-profile tailstock: 00RX856 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
EL54 PCIe3 2-port 10 GbE NIC and RoCE SR adapter (FC EL54; CCIN 57BE); Adapter FRU number: 00RX875 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
EL55 PCIe2 2-port 10 GbE BaseT RJ45 Adapter (FC EL55; CCIN 2CC4); Adapter FRU number: 00E2714 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
EL56 PCIe2 4-port (2x10 Gb FCoE, 2x1 GbE) SFP+ Adapter (FC EL56, CCIN 2B93); Adapter FRU number: 00E3498 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
EL57 PCIe2 4-port (10 Gb FCoE and 1 GbE) Copper and RJ45 Adapter (FC EL57; CCIN 2CC1); Adapter FRU number: 00E8140 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
EL58 8 Gb PCI Express Dual-port Fibre Channel Adapter (FC EL58; CCIN 577D); Adapter FRU number: 10N9824 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 6
EL59 PCIe3 RAID SAS quad-port 6 Gb Adapter (FC EL59; CCIN 57B4); Adapter FRU number: 000E9284 1, 7, 4, 10, 3, 9, 6, 12 4 4 4
EL5B PCIe3 16 Gb 2-port Fibre Channel Adapter (FC EL5B; CCIN 577F); Adapter FRU number: 00E3496 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 6
EN0A PCIe3 16 Gb 2-port Fibre Channel Adapter (FC EN0A; CCIN 577F); Adapter FRU number: 00E3496 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 6
EN0G PCIe2 8Gb 2-Port Fibre Channel Adapter (FC EN0F and EN0G; CCIN 578D); Adapter FRU number: 00WT111 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
EN0H PCIe3 4-port (2x10 Gb FCoE, 2x1 GbE) SFP+ Adapter (FC EN0H; CCIN 2B93); Adapter FRU number: 00E3498 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
EN0K PCIe3 4-port (10 Gb FCoE and 1 GbE) Copper and RJ45 Adapter (FC EN0K; CCIN 2CC1); Adapter FRU number: 00E8140 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
EN0M PCIe3 4-port (10 Gb FCoE and 1 GbE) LR and RJ45 Adapter (FC EN0M; CCIN 2CC0); Adapter FRU number: 00E8144 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
EN0S PCIe2 4-port (10 Gb + 1 GbE) SR+RJ45 Adapter (FC EN0S; CCIN 2CC3); Adapter FRU number: 00E2715; Part number (Full-height tailstock): 00E2863; Part number (Low-profile tailstock): 00E2720 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
EN0U PCIe2 4-port (10 Gb + 1 GbE) Copper SFP+RJ45 Adapter (FC EN0U; CCIN 2CC3); Adapter FRU number: 00E2715; low-profile tailstock: 00E2720 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
EN0W PCIe2 2-port 10 GbE BaseT RJ45 Adapter (FC EN0W; CCIN 2CC4); Adapter FRU number: 00E2714 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
EN12 PCIe2 FH 4-port 8 Gb Fibre Channel Adapter (FC EN12; CCIN EN0Y); Adapter FRU number 00WT107 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 0
EN13 and EN14 PCIe Binary Synchronous Adapter (FC EN13 and FC EN14; CCIN 576C) 6, 12 0 0 1
EN15 PCIe3 4-port 10 GbE SR Adapter (FC EN15; CCIN 2CE3); Adapter FRU number: 00ND466; full-height tailstock: 00ND462 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 6
EN17 PCIe3 4-port 10 GbE SFP+ Copper Adapter (FC EN17, CCIN 2CE4); Adapter FRU number: 00ND463; full-height tailstock part number: 00ND465 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 6
EN27 PCIe 2-port Async EIA-232 Adapter (FC EN27; CCIN 57D4); Adapter FRU number: 000ND487 2, 8, 3, 9, 5, 11, 6, 12, 1, 7, 4, 10 6 6 6
EN29 PCIe 2-port Async EIA-232 LP Adapter (FC EN29; CCIN 57D4); adapter FRU number 000ND487 2, 8, 3, 9, 5, 11, 6, 12, 1, 7, 4, 10 0 0 6
ESA3 PCIe2 1.8 GB Cache RAID SAS Adapter Tri-port 6 Gb (FC ESA3; CCIN 57BB); Adapter FRU number: 74Y7131 1, 7, 4, 10, 2, 8, 3, 9, 5, 11, 6, 12 6 6 6

1The slot priority sequence is based on a EMX0 PCIe3 expansion drawer configured with two PCIe3 6-slot fanout modules.

2The maximum number of adapters supported per PCIe3 6-slot fanout module.




Last updated: Thu, November 05, 2020