Troubleshooting
Problem
Attempts to launch IBM Rational Quality Manager v4.0 post upgrade results in error "CRJAZ2343E The license Quality Professional-Token is incompatible with the application"
Symptom
You receive the following error message:
Error 500
An error response was received from the Jazz Team Server. Status=400. Message: CRJAZ2343E The license "Quality Professional-Token" is incompatible with the application "cca96122-0285-47df-9d17-78ae2b03bdf8" which is requesting a checkout.
The license has specified an application compatible behavior of: " ". The application has a compatible behavior of: "QualityManager-4.0". This could be because the license is old and the application has been upgraded and the license is no longer valid. If this is the case, the license should also be upgraded in order to work with the application.
Cause
An incorrect Server Activation license Kit for was imported for Rational Quality Manager.
Diagnosing The Problem
Verify and confirm the Activation kit that you are importing is for the version of Rational Quality Manager installed on the system
Resolving The Problem
In order to resolve the reported error; apply the steps below:
- Navigate to IBM Rational License Key Center website
- Return the existing license.dat file
- Re-generate the new licenses by using Get Keys in the left navigation pane under section My License Keys
This would enable the Jazz Keys (JazzTokens.zip) to be updated for Rational Quality Manager v4.0
- Download the new JazzTokens.zip
- Import the JazzTokens.zip on the Jazz Team Server