PM95649: object heading and text can be edited with only read access

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The object heading and object text attributes can be edited by a
    user who only has read access to the attribute value.
    
    To recreate:
    
     - create a module with some objects
     - restrict access to he values of object heading and object
    text to read-only for a given user
     - open the module as that user
     - right-click an object and open its properties dialog
     - now select the object again, so the focus returns to the
    module window
     - type some text (it will not appear) then select a different
    object
     - the first character of the text typed will be applied
    
    The modification will be applied to the heading if a previous
    heading value edisted, otherwise it will be applied to the
    object text.
    
    Workaround:
    
    Implement your own ACL system using a trigger.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The object heading and object text attributes can be edited
    by a user who only has read access to the attribute value.
    
    To recreate:
    
     - create a module with some objects
     - restrict access to he values of object heading and object
    text to read-only for a given user
     - open the module as that user
     - right-click an object and open its properties dialog
     - now select the object again, so the focus returns to the
    module window
     - type some text (it will not appear) then select a
    different object
     - the first character of the text typed will be applied
    
    The modification will be applied to the heading if a
    previous heading value edisted, otherwise it will be applied
    to the object text.
    
    Workaround:
    
    Implement your own ACL system using a trigger.
    

Problem conclusion

  • The code has been changed so that the product issue no
    longer occurs.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM95649

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    930

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-08-22

  • Closed date

    2013-12-13

  • Last modified date

    2013-12-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R930 PSN

       UP