IBM Support

PM95071: CREATING MESSAGES FROM WSDL GIVES INVALID XML CONTENT

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • In some circumstances a message created from a WSDL schema
    results in incorrect namespace declarations in the XML payload.
    
    When the message is received by the target system it cannot be
    parsed and used.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users of Rational Integration Tester                     *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * In some cases Rational Integration Tester could send and XML *
    * message (via SendRequest or Publish actions) that referred   *
    * to a namespace on an element without first declaring that    *
    * namespace. This would cause the receiving application to     *
    * fail to parse the XML and the test would not run.            *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Updated to Rational Integration Tester 8.5.0.2 where this    *
    * problem has been resolved.                                   *
    ****************************************************************
    

Problem conclusion

  • This problem was resolved in Rational Integration Tester
    8.5.0.2.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM95071

  • Reported component name

    RATL INTEGRA TE

  • Reported component ID

    5725G79IT

  • Reported release

    801

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-08-14

  • Closed date

    2013-09-27

  • Last modified date

    2013-09-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL INTEGRA TE

  • Fixed component ID

    5725G79IT

Applicable component levels

  • R800 PSN

       UP

  • R801 PSN

       UP

  • R850 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.1","Line of Business":{"code":"LOB45","label":"Automation"}}]