PM93560: Copy Baseline does not retain 'Show descendants' option in filtered views

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Copy Baseline does not retain 'Show descendants' option in
    filtered views
    
    Steps to reproduce:
    - Create a module
    - Create a filter with Show descendants checked
    - Save the filter as a view
    - Baseline the module
    - Create a copy of the baseline (Baseline -? Copy)
    - In the newly created module, the filter does not have 'Show
    descendants' checked.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Copy Baseline does not retain "Show descendants" option in
    filtered views. A baseline containing a view with show
    descendants option checked in its filter settings, is not
    copied into the new baseline created using copy baseline
    option.
    

Problem conclusion

  • Function to retain 'Show descendants' option was missing.
    Added to correct the behavior.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM93560

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    920

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-07-22

  • Closed date

    2013-12-13

  • Last modified date

    2013-12-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R920 PSN

       UP