IBM Support

PM92481: Rational Developer for System z (RDz) - Editorss in RDz restricts the DEFAULT RANGE(ABC) to the exact name 'ABC'

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Headline/Abstract:
    ***************************************************************
    Rational Developer for System z (RDz): Editors in RDz
    restricts the DEFAULT RANGE(ABC) to the exact name 'ABC'
    
    APAR Error Description:
    ***************************************************************
    Rational Developer for System z - RDz - V8.5.1.1
    
    LPEX Editor and PL/I Editor restrict the DEFAULT RANGE(ABC)
    to the exact name 'ABC' while it should apply to names that
    begin with 'ABC'.
    
    PL/I Language Reference says:
        RANGE(identifier)
         Specifies that the defaults apply to names that begin
         with the same letters as in the identifier specified.
         For example:
         RANGE (ABC)
         applies to these names:
         ABC
         ABCD
         ABCDE
    
    ***************************************************************
    Local fix:
    None
    

Local fix

Problem summary

  • The parser treated default range prefixes like variables that
    needed to be resolved.
    

Problem conclusion

  • Modified variable resolution to treat default range prefixes
    appropriately.
    
    The problem listed in this APAR has been resolved with
    IBM Rational Developer for System z V8.5.1.4 Fix Pack which
    is available from the Recommended Fixes support download page:
    http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM92481

  • Reported component name

    RATL DEV FOR SY

  • Reported component ID

    5724T0700

  • Reported release

    850

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-07-08

  • Closed date

    2013-10-16

  • Last modified date

    2013-10-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL DEV FOR SY

  • Fixed component ID

    5724T0700

Applicable component levels

  • R850 PSY

       UP



Document information

More support for: Rational Developer for System z

Software version: 8.5

Reference #: PM92481

Modified date: 16 October 2013