IBM Support

PM92059: Invalid OSLC Response error is seen while opening a module

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Invalid OSLC Response error is seen while opening a module
    
    Steps to reproduce:
    - Configure DOORS to consume RDM services
    - Create a module - A, and create couple of links to artfiacts
    in an RDM Project, say Project A.
    - Exit DOORS.
    - Login to DOORS as another user.
    - Open the module - A. When prompted to authenticate for RDM,
    provide details of a user that does NOT have access to Project A
    in RDM.
    
    User will get the following error(s):
    Some of the external links will not be visible due to link
    discovery error
    Invalid OSLC resource response
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Since the logged in user does not have access permission to
    the given project area, link discovery returns back a 404
    

Problem conclusion

  • Only users who have permissions set on the jazz project area
    can view links
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM92059

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    950

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-06-28

  • Closed date

    2013-12-13

  • Last modified date

    2013-12-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R950 PSN

       UP