IBM Support

PM83644: value of oauth domain in friendsconfig.rdf is removed for every first login to DWA after startup

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Problem
    value of oauth domain in friendsconfig.rdf is removed for every
    first login to DWA after startup
    
    To Reproduce
    - install DWA 9.5
    - install RQM 4.0.0 or 4.0.1
    - set up Consumer Inbound (QM) and Remote services in DOORS.
    Associate QM Project with DOORS ERS Services
    - start DWA and Jazz Server
    - log into DWA -? Everything is fine. Link can be created to
    RQM. Pls check friendsconfig.rdf if the value is set for line
    ?jfs:oauthDomain rdf:resource=''/?, in my example
    '?jfs:oauthDomain rdf:resource='https://felix3:9443/qm'/?'
    - stop DWA and JAzz Server
    - start DWA ? Jazz again and log into DWA -? check again
    friendsconfig.rdf -? you'll see that the value is removed for
    ?jfs:oauthDomain rdf:resource=''/?
    
    Expected Results
    value of oauth domain, e.g.'https://felix3:9443/qm' should be
    kept
    
    Actual Results
    value of oauth domain is removed after every first log in after
    DWA startup
    
    Possible Workarounds
    - start DWA and Jazz
    - log into DWA -? oauth domain value is removed again
    - log off DWA
    - open friendsconfig.rdf and set value for oauth domain manually
    - save file
    - log again into DWA and check file again
    
    Additional Notes
    - if the value of oauth domain is missing then its not possible
    to create OSLC links using DWA
    - also the hoover function will not pop up
    - internal server error CRCRW5065E is produced
    
    - everytime that the DWA components are started the oauth domain
    value is removed after the first log in to DWA
    - this value can be set manually and it works until DWA is
    restarted
    

Local fix

Problem summary

  • Problem
    value of oauth domain in friendsconfig.rdf is removed for every
    first login to DWA after startup
    
    To Reproduce
    - install DWA 9.5
    - install RQM 4.0.0 or 4.0.1
    - set up Consumer Inbound (QM) and Remote services in DOORS.
    Associate QM Project with DOORS ERS Services
    - start DWA and Jazz Server
    - log into DWA -> Everything is fine. Link can be created to
    RQM. Pls check friendsconfig.rdf if the value is set for line
    <jfs:oauthDomain rdf:resource=""/>, in my example
    "<jfs:oauthDomain rdf:resource="https://felix3:9443/qm"/>"
    - stop DWA and JAzz Server
    - start DWA & Jazz again and log into DWA -> check again
    friendsconfig.rdf -> you'll see that the value is removed for
    <jfs:oauthDomain rdf:resource=""/>
    
    Expected Results
    value of oauth domain, e.g."https://felix3:9443/qm" should be
    kept
    
    Actual Results
    value of oauth domain is removed after every first log in after
    DWA startup
    
    Possible Workarounds
    - start DWA and Jazz
    - log into DWA -> oauth domain value is removed again
    - log off DWA
    - open friendsconfig.rdf and set value for oauth domain manually
    - save file
    - log again into DWA and check file again
    
    Additional Notes
    - if the value of oauth domain is missing then its not possible
    to create OSLC links using DWA
    - also the hoover function will not pop up
    - internal server error CRCRW5065E is produced
    
    - everytime that the DWA components are started the oauth domain
    value is removed after the first log in to DWA
    - this value can be set manually and it works until DWA is
    restarted
    

Problem conclusion

  • The documentation has been improved in this area of
    functionality.
    

Temporary fix

  • Not applicable. This is a documentation issue
    

Comments

APAR Information

  • APAR number

    PM83644

  • Reported component name

    RATL TEAM CONCE

  • Reported component ID

    5724V0400

  • Reported release

    950

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-02-26

  • Closed date

    2013-12-12

  • Last modified date

    2013-12-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R952 PSY

       UP