PM75171: APPLYING AN XSD SCHEMA ALTERS FIELD ORDER

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • STEPS TO REPRODUCE:
    
    In the Message Editor in Test Factory you can paste XML into the
    text field of a message to
    build the message tree.
    
    You can then apply an XSD schema to this message.
    
    EXPECTED RESULTS:
    
    After applying the schema, the fields should remain in the same
    order if they already comply with the schema
    
    ACTUAL RESULTS:
    
    After applying the schema and retaining data the field the order
    has changed. This results in errors when running the test as
    received message field ordering does not match that expected.
    
    WORKAROUND:
    
    Manually change the field order in the Message Editor with the
    Move Up/Move Down right-click options
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users of GH Tester and Rational Integration Tester       *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * If an XML schema is applied to a message in the message      *
    * editor using the Retain Data option then the elements in the *
    * message may be re-ordered even though it did already adhere  *
    * to the schema definition.                                    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to Rational Integration Tester 8.5.1                 *
    ****************************************************************
    

Problem conclusion

  • This problem was resolved in Rational Integration Tester 8.5.1.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM75171

  • Reported component name

    GREEN HAT TESTE

  • Reported component ID

    5725G79GT

  • Reported release

    540

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-10-17

  • Closed date

    2013-11-21

  • Last modified date

    2013-11-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    GREEN HAT TESTE

  • Fixed component ID

    5725G79GT

Applicable component levels

  • R540 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSGNUH","label":"Green Hat Tester"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
21 November 2013