A fix is available
APAR status
Closed as program error.
Error description
Unable to add comments on the discussion in DOORS created by DWA. Configuration: DOORS DDBS/Client 9.4 DWA 1.5.0.0 Windows 7 32 bit IE 8 STEPS TO REPRODUCE: - open the module in DWA review mode - Select an object, on the discussion tab select new discussion - fill in 'Summary' and ' Comment' fields and click the green arrow to save this. - In DOORS, select the same object and Discussions from the menu options?View Object discussions - Add comment?Submit - Receive message 'This discussion includes a comment on modified data. Please reload the module before proceeding.' - You cannot submit a comment on this discussion
Local fix
Problem summary
Unable to add comments in DOORS on discussions created by DWA.
Problem conclusion
Problems with the DWA interop converting times meant that the times are being created in the past.
Temporary fix
Upgrade to 9.5 or newer.
Comments
This happens in versions of DOORS prior to DOORS 9.5.1.2
APAR Information
APAR number
PM71999
Reported component name
TLOGIC DOORS WE
Reported component ID
5724V97WA
Reported release
940
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-08-31
Closed date
2013-11-07
Last modified date
2013-11-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC DOORS
Fixed component ID
5724V61DR
Applicable component levels
R951 PSY
UP