A fix is available
APAR status
Closed as program error.
Error description
RDz PLISAXC-based XML2LS converters cannot find root element when parsing Unicode XML. The following error message occurs with RDz 8.5: IRZ0962S XML to language structure conversion could not complete in procedure (name) because no element names in the XML document were recognized by the converter. *
Local fix
Problem summary
One of the new converter routines, qualify_local_name, introduced in V8.5 was not written correctly. It was not written to expect unicode XML and an element not qualified with namespaces.
Problem conclusion
The routine "qualify_local_name" of the XML2PLI converter has been corrected to work with unicode XML and an element not qualified with namespaces. The problem listed in this APAR has been resolved with IBM Rational Developer for System z V8.5.1 Refresh Pack which is available from the Recommended Fixes support download page: http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
Temporary fix
Comments
APAR Information
APAR number
PM69785
Reported component name
RATL DEV FOR SY
Reported component ID
5724T0700
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-07-27
Closed date
2012-11-26
Last modified date
2012-11-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL DEV FOR SY
Fixed component ID
5724T0700
Applicable component levels
R850 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSTRMM","label":"IBM Developer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"850","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]