IBM Support

PM51166: Unable to Create 'Implemented By' links from RTC when the module has a view with a Layout column from Analysis Wizard

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When trying to create an 'Implemented By' link from RTC to a
    DOORS module the following error will be generated if the module
    being linked to has a view with a Layout DXL column that was
    created using the Analysis Wizard.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Steps to Reproduce
    
    1  Create a module in DOORS with a few objects and some
    links.
    2. Run Analysis Wizard on the module for outlinks.
    3. Save the column created in a new view.
    4. Using RTC add the module under "Associations -
    Implemented By" in RTC Project Area.
    5. Open an existing workitem in RTC and try to add a
    "Implemented By" link to a module object.
    6. The error will be seen when saving the workitem.
    

Problem conclusion

  • The OSLC "put" request was incorrectly including Layout DXL,
    which was causing an "Attribute Not Found" error to be
    returned in this case.
    
    Layout DXL is generated dynamically and is read-only, and
    should not have been included in the "put".
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM51166

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    930

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-10-31

  • Closed date

    2012-06-08

  • Last modified date

    2012-06-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R930 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSYQBZ","label":"Rational DOORS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.3","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]