A fix is available
APAR status
Closed as program error.
Error description
Attribute features that affect change bars, change dates, and generate history remain checked in the edit attribute dialog even after you uncheck them. Steps to reproduce: 1. With a DOORS 9.3.0.4 client, create a new module 2. In the new module, create a new object attribute 3. For this new attribute uncheck the 'Attribute features' for 'Affect change bars', 'Affect change dates', and 'Generate history' then click the OK button 4. Then edit that same attribute again and notice those check boxes are still checked Expected results: When you uncheck the options for those attribute features, they should remain unchecked Actual results: The attribute features remain checked Notes: With the steps above, if you point a DOORS 9.3.0.3 client to the same data, you will notice those check boxes are unchecked as they should be. So a workaround is to use a DOORS client version prior to 9.3.0.4 This can cause some serious discrepancies. For example, if you uncheck those options and modify that attribute for an object then the change bars, change dates, and history are not effected. But someone may think this is acting incorrectly. They may think the change dates, change bars, and history should actually be effected since the GUI indicates those options are checked.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** The check boxes in Attribute features not working correctly.
Problem conclusion
The dependencies between different check boxes in Attribute features is corrected now.
Temporary fix
Comments
This happens in versions of DOORS prior to DOORS 9.3.0.6
APAR Information
APAR number
PM47911
Reported component name
TLOGIC DOORS
Reported component ID
5724V61DR
Reported release
930
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-09-14
Closed date
2011-12-02
Last modified date
2011-12-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC DOORS
Fixed component ID
5724V61DR
Applicable component levels
R930 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSYQBZ","label":"Rational DOORS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.3","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date: