PM46681: DOORS&RTC NO LINK POINT BACK TO DOORS IN RTC

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • The customer is testing the integration between DOORS/DWA and
    RTC for a strong
    positive candidate client, and found the following two issues.
    1. In DOORS client, when creating an object link( New
    implemented by) and
    choose a RTC project, if we choose 'select artifact' and select
    an existing
    RTC workitem, the link will be created in DOORS client, but in
    RTC
    workitem, there is NO link point back to DOORS. on the other
    hand, if we
    choose 'create artifact' to create a new link target, the links
    will be
    successfully created both in RTC and DOORS.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    No link is created in an RTC workitem when creating a
    collaboration link from a DOORS requirement, and choosing
    "select artifact".
    

Problem conclusion

  • Ignore case differences between the DOORSHOME environment
    variable and the installation directory of the DOORS client.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM46681

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    920

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-08-30

  • Closed date

    2011-09-28

  • Last modified date

    2011-09-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R920 PSN

       UP