A fix is available
APAR status
Closed as program error.
Error description
The document generator (available in a formal module under File;Export;Document Generation;PDF...) cannot be used in a module which is read-only, or a baseline. This is because write access is required on the module. Defecct raised at the request of product management.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** RPE - document generator can't be used in read-only modules or baselines
Problem conclusion
DOORS document generation logic was repaired so that document generation process won't add module atributes for each export. now document generation logic will provide export specific information via configuration file
Temporary fix
Comments
APAR Information
APAR number
PM41816
Reported component name
CLEARQUEST WIN
Reported component ID
5724G3600
Reported release
930
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-06-16
Closed date
2011-09-28
Last modified date
2011-09-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC DOORS
Fixed component ID
5724V61DR
Applicable component levels
R930 PSN
UP