PM41779: rebase: Internal Error detected in '\atria\lib\sum\sum_stream.cxx' line 605

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Attempting to rebase a development stream
    FROM a foundation on the 'INITIAL' baseline of a component
      TO a baseline created in a different project
    may yield the error
    
    ---------------------------
    Baseline Validation
    ---------------------------
    INTERNAL ERROR detected and logged with the NT Event Service.
    See the Event Viewer for the error message.
    Internal Error detected in '\atria\lib\sum\sum_stream.cxx' line
    605
    Unexpected error.
    ---------------------------
    OK
    ---------------------------
    
    This happens if the project integration stream does not already
    use the same baseline as foundation.
    
    The rebase should be rejected with the following error:
    
    ---------------------------
    Baseline Validation
    ---------------------------
    Can't use baseline 'Tailpipe_20_City_mileage.5665'
     of component 'engines' because it is not an ancestor of parent
    stream's foundation baseline.
    ---------------------------
    OK
    ---------------------------
    
    
    Steps to Reproduce:
    
    Import a label as a baseline
    Create a project on this foundation
    create development stream
    rebase  the development stream onto a baseline created in a
    different stream
    
    
    Workaround:
    
    None needed. The rebase will be rejected anyway.
    The problem is only that the error displayed does not explain
    the reason.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Attempting to rebase a development stream FROM a foundation
    on the "INITIAL" baseline of a component TO a baseline
    created in a different project
    may yield the error
    
    ---------------------------
    Baseline Validation
    ---------------------------
    INTERNAL ERROR detected and logged with the NT Event
    Service.
    See the Event Viewer for the error message.
    Internal Error detected in "\atria\lib\sum\sum_stream.cxx"
    line 605
    Unexpected error.
    ---------------------------
    OK
    ---------------------------
    
    This happens if the project integration stream does not
    already use the same baseline as foundation.
    
    The rebase should be rejected with the following error:
    
    ---------------------------
    Baseline Validation
    ---------------------------
    Can't use baseline "Tailpipe_20_City_mileage.5665"
     of component "engines" because it is not an ancestor of
    parent stream's foundation baseline.
    ---------------------------
    OK
    ---------------------------
    

Problem conclusion

  • A fix is available in ClearCase versions 7.1.1.8, 7.1.2.5
    and 8.0.0.1
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM41779

  • Reported component name

    CLEARCASE WIN

  • Reported component ID

    5724G2900

  • Reported release

    701

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-06-16

  • Closed date

    2011-12-16

  • Last modified date

    2011-12-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CLEARCASE WIN

  • Fixed component ID

    5724G2900

Applicable component levels

  • R701 PSN

       UP