PM38724: Forename and Surname attributes are not accessible via DXL in DOORS 9.2 and above, when configured with RDS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Forename and Surname attributes are not accessible via DXL in
    DOORS 9.2 and above, when configured with RDS
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Surname and forename were not accessible via DXL when
    configured with RDS. Configure DOORS to use RDS. Ensure
    Forename and Surname are populated in Corporate LDAP/RDS
    users and use u.surname or u.forename to try fetching the
    value in DOORS DXL. Empty strings were returned for
    u.surname and u.forename
    

Problem conclusion

  • 1. Surname Attribute returned forename when Surname field
    was empty for a name. This is corrected. When surname field
    is empty, an empty string is returned
    2. There was no Attribute supplied by RDS to access
    Forename. API is supplied now to fulfill the issue
    
    These Attribute are incorporated to fit into DXL
    requirements. u.surname will return surname, if any, for a
    user and u.forename returns forename of a user.
    
    These Attributes are relevant only when configured to use
    the Rational Directory Server
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM38724

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    920

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-05-09

  • Closed date

    2012-06-06

  • Last modified date

    2012-06-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R920 PSN

       UP