  • System Memory Exhausted error , followed by Exception Access
    Violation, while running spell check on a module with greater
    than 12000 objects.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Defect was seen because of more memory consumption of DOORS
    

Problem conclusion

  • Fixed by imposing memory check on costly operations such as
    big module export and spell check.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM37951

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    920

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-04-28

  • Closed date

    2012-03-09

  • Last modified date

    2012-03-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R920 PSN

       UP



Document information

More support for: Rational DOORS

Software version: 9.2

Reference #: PM37951