A fix is available
APAR status
Closed as program error.
Error description
When DOORS Web Access is enabled, the internal URL referencing the requirement is formatted in a different way. As a result: The Rational Quality Manager Integration only works when the DOORS server is configured for the traditional DOORS Client. DOORS Web Access must be turned off. The Rational Team Concert integration with DOORS requires that the DOORS Web Access client and web interface be enabled.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** When DWA is installed in the user machine, the requirements url changes from the traditional url with 'doors' as protocol to new url with protocol as "http" or "https"(based on DWA setup). Since the url is used as a unique identifier in RQM to store the requirements, the change in URL cause requirements to be uploaded again and the requirements in RQM that are uploaded from DOORS, loses traceability.
Problem conclusion
A new field is added to the data file (XML) used to transfer data from DOORS to RQM while export to hold the URL of the requirement. This will be used only for traceability from RQM to DOORS. The existing field that acts as the identifier for RQM will always contain the traditional URL with protocol as "doors".
Temporary fix
Comments
APAR Information
APAR number
PM34242
Reported component name
TLOGIC DOORS
Reported component ID
5724V61DR
Reported release
930
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-03-07
Closed date
2011-06-29
Last modified date
2011-06-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC DOORS
Fixed component ID
5724V61DR
Applicable component levels
R930 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSYQBZ","label":"Rational DOORS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.3","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]