Error description

  • Problem
    If an attribute value contains non-standard indents, attempts to
    export a RIF defintion containing it will fail with repeated
    'memory exhausted' messages.
    
    In this case the indent depth was 560 units. DOORS indents are
    either 360 units for single indent, or 720 units for two.
    
    Introduced in v9.3
    
    To Reproduce
     - restore the attached module
     - add it to a RIF defintion
     - export the definition
    
    Possible Workarounds
    Modify the indents to be standard DOORS indents.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    If an attribute value contains non-standard indents,
    attempts to export a RIF definition containing it will fail
    with repeated "memory exhausted" messages.
    

Problem conclusion

  • The code has been changed so that the memory exhausted issue
    no longer occurs
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM25609

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    920

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-11-01

  • Closed date

    2011-03-31

  • Last modified date

    2011-03-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR