Error description

  • Problem
    When has more than one section locked and creates objects on
    those sections, unlocking only one section may cause duplicate
    absolute numbers to be created if a second client then locks the
    section which has just been unlocked. You need to be using
    client version 9203 or higher to reproduce this defect.
    
    To Reproduce
    - using client 9203 or higher, create a module with a simple
    structure, for example
    
    1.
    1.1
    2.
    2.1
    3.
    3.1
    
    - make 1, 2 and 3 sections and save the module. close.
    - with client A and B open the module in edit shareable mode
    - with client A, lock sections 1 and 2
    - with client C, lock section 3
    - with client A add objects to sections 1 and 2
    - with client A, unlock and save section 1
    - with client B, lock section 1
    - with client B, create some objects
    
    Now compare the module windows from client A and client B. You
    will see duplicate absolute numbers.
    
    Possible Workarounds
    Downgrade to 9202 client.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When a user has more than one section locked and creates
    objects on those sections, unlocking only one section may
    cause duplicate absolute numbers to be created if a second
    client then locks the section which has just been unlocked.
    

Problem conclusion

  • The code has been changed so the duplicate number scenario
    cannot occur.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM20773

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    920

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-08-18

  • Closed date

    2010-12-06

  • Last modified date

    2010-12-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R920 PSN

       UP



Document information

More support for: Rational DOORS

Software version: 9.2

Reference #: PM20773

Modified date: 06 December 2010