IBM Support

PM14559: specific access rights on a module set back to inherited after r estoring to the same database

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Problem
    If your database name has hyphens in it you cannot preserve spec
    ific access rights when you restore to the same database. Instea
    d, the permissions are set back to inherited.
    
    To Reproduce
    - create a new db
    - in the db properties, edit the name so it contains a hyphen [m
    y-name]
    - create some users and groups
    - create a project
    - uncheck the 'inherited' box and add some specific ACLs
    - archive the project
    - restore it to the same location
    - look at the properties; the specific access rights have been r
    emoved and access has been set to inhertited
    
    Possible Workarounds
    remove the hyphens from the name or use underscores....
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    With a database name containing hyphens, it is not possible
    to preserve specific access rights when you restore to the
    same database. Instead, the permissions are set back to
    inherited.
    

Problem conclusion

  • The code has been changed so that the access rights are
    preserved.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PM14559

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    920

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-05-14

  • Closed date

    2010-09-17

  • Last modified date

    2010-09-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R920 PSN

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSKR2T","label":"IBM Engineering Requirements Management DOORS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.2","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]