APAR status
Closed as program error.
Error description
Problem Analysis Wizard does not allow end-to-end traceability analysis when a module in the traceability chain has a default view set t hat shows only those objects with no links. To Reproduce 1. Create 3 modules (Mod1, Mod2, Mod3) with some data. 2. Create some traceability links from Mod3 to Mod2 to Mod1 maki ng sure that you have end-to-end traceability between the three modules. 3. In Mod2, create a filtered view that shows only those objects that have no incoming or outgoing links. 4. Save the view created in Mod2 and make it as default view for all users. 5. Run the analysis Wizard from Mod3 and follow outgoing links t o try and show end-to-end traceability. In the 'Other informatio n' section of the Wizard, use the following settings: i. Enable Recursive analysis ii. Select the 'Display information only from selected modules ' option. iii. Select the 'Next...' button. This should display the 'Mod 2' module. iv. Select the Mod2 module and press the 'Next...' button. PRO BLEM: Mod1 is not displayed. Possible Workarounds The work-around is that the user needs to open Mod2 disable the module's filter, and leave the module open while doing the analy sis.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** The Analysis Wizard does not allow end-to-end traceability analysis when a module in the traceability chain has a default view set that shows only those objects with no links.
Problem conclusion
The code has been changed so that the module with the view causing the issue does not cause the problem
Temporary fix
Comments
APAR Information
APAR number
PM14451
Reported component name
TLOGIC DOORS
Reported component ID
5724V61DR
Reported release
920
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-05-13
Closed date
2010-09-17
Last modified date
2010-09-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC DOORS
Fixed component ID
5724V61DR
Applicable component levels
R920 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSKR2T","label":"IBM Engineering Requirements Management DOORS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.2","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]