Error description
When opening a DOORS module that is under Change control in Exclusive Edit, and selecting a default RCR, if you do not have sufficient (i.e., RMCD in DOORS) access to that module, then the module just closes and you get no message or indication of what the issue is. How to reproduce: 1. Log into DOORS with database administrator 2. Create a user e.g. Test_1 in DOORS 3. Create a test module 4. Assign Test_1 user a Read_only access to the module created in step 3 5. Configure module for the DOORS-Change Integration 6. log into DOORS with user Test_1 (created in step 2) 7. Open the module created on step 3 8. Submit an RCR 9. Assign RCR to Test_1 10. From the module, go to Change Management -? Requirements Change Request -? Select Default 11. Select Default RCR from the list and click OK You will notice, the module closes without any warnings.
Local fix
workaround not available.
Problem summary
**************************************************************** * USERS AFFECTED: * **************************************************************** * PROBLEM DESCRIPTION: * **************************************************************** * RECOMMENDATION: * **************************************************************** While opening a module the integration gives no warning that user did not have sufficient rights and closes the module.
Problem conclusion
This fix is available in Doors-Change Management 9.3.0.3 If a user does not have sufficient access rights to the module they will be warned during select default RCR operation.
Temporary fix
Comments
APAR Information
APAR number
PM00984
Reported component name
TLOGIC CHANGE
Reported component ID
5724V87CG
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-11-11
Closed date
2011-03-16
Last modified date
2011-03-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TLOGIC CHANGE
Fixed component ID
5724V87CG
Applicable component levels
R520 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSYQQ2","label":"Rational Change"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]